ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Arun K. Singhal
Mahender Macha
James B. McClurken
Satoshi Furukawa
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Piacentino, V.
Right arrow Articles by Furukawa, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Piacentino, V., III
Right arrow Articles by Furukawa, S.
Related Collections
Right arrow Mechanical Circulatory Assistance

Ann Thorac Surg 2003;75:607-609
© 2003 The Society of Thoracic Surgeons


How to do it

Off-pump technique for Thoratec left ventricular assist device insertion

Valentino Piacentino, III, PhDa, Arun K. Singhal, MD, PhDa, Mahender Macha, MDa, James B. McClurken, MDa, Carol A. Fisher, BAa, Satoshi Furukawa, MD*a

a Department of Surgery, Division of Cardiac and Thoracic Surgery, Temple University Hospital, Philadelphia, Pennsylvania, USA

Accepted for publication July 31, 2002.

* Address reprint requests to Dr Furukawa, Cardiopulmonary Transplantation, 3401 North Broad St, Philadelphia, PA19140, USA
e-mail: furukas{at}tuhs.temple.edu

We present a case of left ventricular assist device (Thoratec; Thoratec Laboratories Corp, Pleasanton, CA) insertion performed through a left thoracotomy without cardiopulmonary bypass in a patient with severe end-stage congestive heart failure with renal and respiratory dysfunction and a history of multiple cardiac operations.




This article has been cited by other articles:


Home page
ICVTSHome page
F. Collart, H. Feier, D. Metras, and T. G. Mesana
A safe, alternative technique for off-pump left ventricular assist device implantation in high-risk reoperative cases
Interactive CardioVascular and Thoracic Surgery, June 1, 2004; 3(2): 286 - 288.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2003 by The Society of Thoracic Surgeons.