ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Michael K. Banbury
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Banbury, M. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Banbury, M. K.
Related Collections
Right arrow Mechanical Circulatory Assistance

Ann Thorac Surg 2003;75:297
© 2003 The Society of Thoracic Surgeons


How to do it

Stapled explant of the Jarvik 2000 left ventricular assist device

Michael K. Banbury, MDa*

a Department of Thoracic and Cardiovascular Surgery, Cleveland Clinic Foundation, Cleveland, Ohio, USA

Accepted for publication July 22, 2002.

* Address reprint requests to Dr Banbury, The Cleveland Clinic Foundation, 9500 Euclid Ave, Desk F24, Cleveland, OH 44195, USA
e-mail: banburm{at}ccf.org

Currently the most common indication for placement of a left ventricular assist device is as a bridge to heart transplantation. One of the new generation axial flow left ventricular assist devices is the Jarvik 2000. This device is placed in the apex of the left ventricle and the outflow graft passes through the left pleural space and is anastomosed to the descending thoracic aorta. The course of the outflow graft presents technical challenges during explant for heart transplantation. Opening the posterior pericardium and use of a vascular stapler to control the outflow graft at the level of the descending thoracic aorta facilitates easy explantation.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
K. Yamane, L. J. Bogar, P. J. DiMuzio, S. W. Cowan, H. Hirose, N. R. Evans III, A. S. Rao, J. A. Eisenberg, and N. C. Cavarocchi
Contained Rupture of a Pseudoaneurysm of the Descending Thoracic Aorta Related to Remnant Outflow Graft of Left Ventricular Assist Device After Heart Transplantation
Ann. Thorac. Surg., October 1, 2012; 94(4): 1345 - 1348.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
E. N. Sorensen, R. N. Pierson III, E. D. Feller, and B. P. Griffith
University of Maryland Surgical Experience With the Jarvik 2000 Axial Flow Ventricular Assist Device
Ann. Thorac. Surg., January 1, 2012; 93(1): 133 - 140.
[Abstract] [Full Text] [PDF]


Home page
Eur J Cardiothorac SurgHome page
B. Hohlweg-Majert, R. Gutwald, M. P. Siegenthaler, and R. Schmelzeisen
Implantation of the Jarvik 2000 left-ventricular-assist-device: role of the maxillofacial surgeon
Eur J Cardiothorac Surg, August 1, 2005; 28(2): 337 - 339.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2003 by The Society of Thoracic Surgeons.