ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Schröder, W.
Right arrow Articles by Hölscher, A. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Schröder, W.
Right arrow Articles by Hölscher, A. H.
Related Collections
Right arrow Esophagus - other

Ann Thorac Surg 2002;74:1917-1922
© 2002 The Society of Thoracic Surgeons


Original article: general thoracic

Does continuous mucosal partial carbon dioxide pressure measurement predict leakage of intrathoracic esophagogastrostomy?

Wolfgang Schröder, MDa*, Dirk Stippel, MDa, Martin Lacher, MDa, Christian A. Gutschow, MDa, K.Tobias E. Beckurts, MD,a, Arnulf H. Hölscher, MD, FACS, FRCSa

a Department of Visceral and Vascular Surgery, University of Cologne, Cologne, Germany

Accepted for publication July 2, 2002.

* Address reprint requests to Dr Schröder, Department of Visceral and Vascular Surgery, University of Cologne, Joseph-Stelzmann Str 9, 50931 Cologne, Germany.
e-mail: wolfgang.schroeder{at}uni-koeln.de

BACKGROUND: Gastroplasty after esophagectomy is associated with relevant morbidity due to anastomotic leakage of the esophagogastrostomy. The aim of this study was to find out whether continuous partial carbon dioxide pressure (pCO2) measurement of the gastric mucosa is an adequate method of monitoring the gastric tube during the postoperative course and of detecting patients with an anastomotic leakage.

METHODS: Forty-seven patients with esophageal cancer underwent esophagectomy and gastric tube formation with intrathoracic esophagogastrostomy. Postoperatively, mucosal pCO2 of the gastric tube (pCO2i) was measured using continuous tonometry (TONOCAP, Datex Ohmeda). pCO2i was related to the arterial pCO2 ({Delta}pCO2 = pCO2i - pCO2a).

RESULTS: A total of 4,338 {Delta}pCO2 measurements were recorded. On average, the pCO2i of each patient was monitored over a period of 92 hours. In 5 patients an anastomotic leakage of the esophagogastrostomy developed. The mean {Delta}pCO2 of this group was 31.7 mm Hg (±19.3 SD) and significantly higher (p < 0.0001) than that of patients without anastomotic leakage (20.7 mm Hg ± 12.8 SD). With a {Delta}pCO2 cut-off point of 56 mm Hg measured for 5 hours, the sensitivity was 0.8, the specifity 0.9, and the positive predictive value 0.5. In patients with anastomotic leakage, the peak {Delta}pCO2 preceded clinical symptoms. False positive {Delta}pCO2 measurements (n = 4) were mainly due to severe pneumonia with long-term ventilation.

CONCLUSIONS: Mucosal pCO2 measurement of the gastric tube can be used as an early indicator of a complicated postoperative course predicting anastomotic leakage of the esophagogastrostomy.




This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
S. Kant
Gastric tip necrosis
Eur. J. Cardiothorac. Surg., August 1, 2005; 28(2): 359 - 359.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The Society of Thoracic Surgeons.