ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Michael E. Jessen
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hamilton, T. T.
Right arrow Articles by Jessen, M. E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hamilton, T. T.
Right arrow Articles by Jessen, M. E.
Related Collections
Right arrow Extracorporeal circulation

Ann Thorac Surg 2002;74:S1408-S1412
© 2002 The Society of Thoracic Surgeons


Supplement: Cardiothoracic Techniques and Technologies

PulseCO: a less-invasive method to monitor cardiac output from arterial pressure after cardiac surgery

Timothy T. Hamilton, MDa, Lynne M. Huber, RNa, Michael E. Jessen, MDa*

a The Department of Cardiovascular and Thoracic Surgery, University of Texas Southwestern Medical Center, Dallas, Texas, USA

* Address reprint requests to Dr Jessen, Department of Cardiovascular and Thoracic Surgery, University of Texas Southwestern Medical Center, 5323 Harry Hines Boulevard, Dallas TX 75390-8879, USA.
e-mail: michael.jessen{at}utsouthwestern.edu

Presented at the Eighth Annual Cardiothoracic Techniques and Technologies Meeting 2002, Miami Beach, FL, Jan 23–26, 2002.

BACKGROUND: Cardiac output is often monitored after cardiac operations with a pulmonary artery catheter. A new method has been introduced that measures cardiac output by lithium dilution (LiDCO) and uses these data to calibrate a system (PulseCO) that calculates cardiac output continuously from the energy of the arterial pressure waveform. It is unknown whether PulseCO measurements are valid early after cardiac surgery when changes in temperature and vascular tone or intermittent use of the arterial line for blood sampling may occur. This study assessed the reliability of cardiac output determinations by PulseCO in the first 8 hours after cardiac surgery.

METHODS: After a one-time PulseCO calibration, cardiac output was measured in 20 patients who had undergone coronary artery bypass grafting at 0, 2, 4, 6, and 8 hours after arrival in the intensive care unit using (1) thermodilution through a pulmonary artery catheter (Thermo); (2) lithium dilution (LiDCO); and (3) PulseCO. Concordance correlations were calculated between methods, and differences were compared by Wilcoxon paired rank test and Bland-Altman analysis.

RESULTS: Cardiac output ranged from 3.4 to 8.5 L/min. No significant differences were noted between measurements obtained by each technique at any time point. Concordance correlations and Bland-Altman analysis confirmed good agreement between PulseCO and Thermo determinations of cardiac output during the study interval.

CONCLUSIONS: PulseCO measurements remain reliable without recalibration for at least 8 hours after cardiac surgery and may offer a less-invasive approach for early postoperative cardiac output monitoring.




This article has been cited by other articles:


Home page
Anesth. Analg.Home page
J. Vuyk, B. J. Lichtenbelt, E. Olofsen, J. W. van Kleef, and A. Dahan
Mixed-Effects Modeling of the Influence of Midazolam on Propofol Pharmacokinetics
Anesth. Analg., May 1, 2009; 108(5): 1522 - 1530.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
F. Compton and J.-H. Schafer
Noninvasive Cardiac Output Determination: Broadening the Applicability of Hemodynamic Monitoring
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 2009; 13(1): 44 - 55.
[Abstract] [PDF]


Home page
J. Appl. Physiol.Home page
H. M. C. Kemps, E. J. M. Thijssen, G. Schep, B. T. H. M. Sleutjes, W. R. De Vries, A. R. Hoogeveen, P. F. F. Wijn, and P. A. F. M. Doevendans
Evaluation of two methods for continuous cardiac output assessment during exercise in chronic heart failure patients
J Appl Physiol, December 1, 2008; 105(6): 1822 - 1829.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
B. Matthieu, N.-G. Karine, C. Vincent, V. Alain, C. J. Francois, R. Philippe, and S. Francois
Cardiac Output Measurement in Patients Undergoing Liver Transplantation: Pulmonary Artery Catheter Versus Uncalibrated Arterial Pressure Waveform Analysis
Anesth. Analg., May 1, 2008; 106(5): 1480 - 1486.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
P. Giomarelli, B. Biagioli, and S. Scolletta
Cardiac output monitoring by pressure recording analytical method in cardiac surgery
Eur. J. Cardiothorac. Surg., September 1, 2004; 26(3): 515 - 520.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The Society of Thoracic Surgeons.