ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Roger J.F. Baskett
Andrew Maitland
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Baskett, R. J.F.
Right arrow Articles by Hirsch, G. M.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Baskett, R. J.F.
Right arrow Articles by Hirsch, G. M.
Related Collections
Right arrow Mechanical Circulatory Assistance

Ann Thorac Surg 2002;74:1276-1287
© 2002 The Society of Thoracic Surgeons


Review

The intraaortic balloon pump in cardiac surgery

Roger J.F. Baskett, MD*a, William A. Ghali, MDb, Andrew Maitland, MBc, Gregory M. Hirsch, MDa

a The Maritime Heart Centre, Dalhousie University, Halifax, Nova Scotia, Canada
b Department of Medicine, University of Calgary, Calgary, Alberta, Canada
c Department of Surgery, University of Calgary, Calgary, Alberta, Canada

* Address reprint requests to Dr Baskett, Maritime Heart Centre, Room 2269, 2nd Floor, 1796 Summer Street, Halifax, NS, B3H 3A7, Canada
e-mail: rogerbaskett{at}hotmail.com

The intraaortic balloon pump (IABP) has been used in cardiac operations since the late 1960s. Over the years, with refinements in technology, its use has expanded; the IABP is now the most commonly used mechanical assist device in cardiac operative procedures. This review provides an evaluation of evidence for the efficacy of IABP use in different clinical scenarios, using the American College of Cardiology/American Heart Association classification of evidence where appropriate. We evaluated complications and outcomes associated with IABP use, and attempted to draw conclusions regarding the use of the IABP in different clinical situations. We examined the trends and variation in utilization over time and across centers. We discussed the IABP in light of new cardiac assist devices and the changing patient population and management strategies. Lastly, we identified areas of future research.




This article has been cited by other articles:


Home page
J. Appl. Physiol.Home page
C. Kolyva, G. M. Pantalos, G. A. Giridharan, J. R. Pepper, and A. W. Khir
Discerning aortic waves during intra-aortic balloon pumping and their relation to benefits of counterpulsation in humans
J Appl Physiol, November 1, 2009; 107(5): 1497 - 1503.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
A. Miceli, B. Fiorani, T. H. Danesi, G. Melina, and R. Sinatra
Prophylactic intra-aortic balloon pump in high-risk patients undergoing coronary artery bypass grafting: a propensity score analysis
Interactive CardioVascular and Thoracic Surgery, August 1, 2009; 9(2): 291 - 294.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
F. Onorati, G. Santarpino, A. Rubino, L. Cristodoro, C. Scalas, and A. Renzulli
Intraoperative bypass graft flow in intra-aortic balloon pump-supported patients: Differences in arterial and venous sequential conduits
J. Thorac. Cardiovasc. Surg., July 1, 2009; 138(1): 54 - 61.
[Abstract] [Full Text] [PDF]


Home page
ANGIOLOGYHome page
P. Dick, W. Mlekusch, G. Delle-Karth, M. Nikfardjam, M. Schillinger, and G. Heinz
Decreasing Incidence of Critical Limb Ischemia After Intra-aortic Balloon Pump Counterpulsation
Angiology, April 1, 2009; 60(2): 235 - 241.
[Abstract] [PDF]


Home page
ICVTSHome page
A. S. Rubino, F. Onorati, G. Santarpino, K. Abdalla, S. Caroleo, E. Santangelo, and A. Renzulli
Early intra-aortic balloon pumping following perioperative myocardial injury improves hospital and mid-term prognosis
Interactive CardioVascular and Thoracic Surgery, March 1, 2009; 8(3): 310 - 315.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. Santarpino, F. Onorati, A. S. Rubino, K. Abdalla, S. Caroleo, E. Santangelo, and A. Renzulli
Preoperative intraaortic balloon pumping improves outcomes for high-risk patients in routine coronary artery bypass graft surgery.
Ann. Thorac. Surg., February 1, 2009; 87(2): 481 - 488.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Takami and H. Masumoto
Effects of Intra-Aortic Balloon Pumping on Graft Flow in Coronary Surgery: An Intraoperative Transit-Time Flowmetric Study
Ann. Thorac. Surg., September 1, 2008; 86(3): 823 - 827.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. A. Pitsis, A. N. Visouli, D. Burkhoff, P. Dardas, N. Mezilis, G. Bougioukas, and G. Filippatos
Feasibility Study of a Temporary Percutaneous Left Ventricular Assist Device in Cardiac Surgery
Ann. Thorac. Surg., December 1, 2007; 84(6): 1993 - 1999.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
J. T Christenson, J. Sierra, J.-A. Romand, M. Licker, and A. Kalangos
Long Intraaortic Balloon Treatment Time Leads to More Vascular Complications
Asian Cardiovasc Thorac Ann, October 1, 2007; 15(5): 408 - 412.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
J.-T. Kim, J.-R. Lee, J.-K. Kim, S. Z. Yoon, Y. Jeon, J.-H. Bahk, K.-B. Kim, C.-S. Kim, Y.-J. Lim, H.-S. Kim, et al.
The Carina as a Useful Radiographic Landmark for Positioning the Intraaortic Balloon Pump
Anesth. Analg., September 1, 2007; 105(3): 735 - 738.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. D. Adams, L. M. Fedoruk, C. A. Tache-Leon, B. B. Peeler, J. A. Kern, C. G. Tribble, J. D. Bergin, and I. L. Kron
Does Preoperative Ejection Fraction Predict Operative Mortality With Left Ventricular Restoration?
Ann. Thorac. Surg., November 1, 2006; 82(5): 1715 - 1720.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
O. V. Hein, J. Birnbaum, K. Wernecke, M. England, W. Konertz, and C. Spies
Prolonged Intensive Care Unit Stay in Cardiac Surgery: Risk Factors and Long-Term-Survival
Ann. Thorac. Surg., March 1, 2006; 81(3): 880 - 885.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
I. R. Ramnarine, A. D. Grayson, W. C. Dihmis, N. K. Mediratta, B. M. Fabri, and J. A.C. Chalmers
Timing of intra-aortic balloon pump support and 1-year survival
Eur. J. Cardiothorac. Surg., May 1, 2005; 27(5): 887 - 892.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
H. Aydin, O. Kandemir, S. Gunaydin, and Y. Zorlutuna
A peeled off and entrapped intraaortic balloon catheter in the femoral artery: an unusual complication
Interactive CardioVascular and Thoracic Surgery, June 1, 2004; 3(2): 314 - 316.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
G H Linley, E W Bakker, R de Vroege, and J J Spijkstra
When the blood-back detection system fails: an IABP case report
Perfusion, December 1, 2003; 18(6): 369 - 371.
[Abstract] [PDF]


Home page
J Intensive Care MedHome page
B. Trotman-Dickenson
Radiology in the Intensive Care Unit (Part I)
J Intensive Care Med, July 1, 2003; 18(4): 198 - 210.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The Society of Thoracic Surgeons.