ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Serdar Gunaydin
Cem Yorgancioglu
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gunaydin, S.
Right arrow Articles by Zorlutuna, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gunaydin, S.
Right arrow Articles by Zorlutuna, Y.
Related Collections
Right arrow Extracorporeal circulation

Ann Thorac Surg 2002;74:819-824
© 2002 The Society of Thoracic Surgeons


Original article: cardiovascular

Clinical performance and biocompatibility of poly(2-methoxyethylacrylate)—coated extracorporeal circuits

Serdar Gunaydin, MD*a, Bora Farsak, MDa, Mustafa Kocakulak, PhDa, Tamer Sari, BSca, Cem Yorgancioglu, MDa, Yaman Zorlutuna, MDa

a Department of Cardiovascular Surgery, Bayindir Hospital, Ankara, Turkey

Accepted for publication May 7, 2002.

* Address reprint requests to Dr Gunaydin, Kizilirmak mah. 8. sok. No: 7/35, Balgat-Ankara 06520, Turkey
e-mail: gunaydin{at}marketweb.net.tr

Background. Poly(2-methoxyethylacrylate) is an amphiphilic organic polymer consisting of a hydrophobic backbone with pendant hydrophilic groups that has been reported to reduce protein and platelet adsorption in in vitro and ex vivo studies.

Methods. Sixty patients undergoing three-vessel coronary artery bypass grafting were divided into two equal groups. Group 1 had operation with Capiox poly(2-methoxyethylacrylate) coated SX18R oxygenators with noncoated circuits, and group 2 had operation with all noncoated circuits. Hemodynamic variables, blood and urine test results, hematologic variables, complement fractions, C3a and C4d, and interleukin-6 levels were documented preoperatively (T1), on cardiopulmonary bypass (T2), before cessation of cardiopulmonary bypass (T3), after protamine sulfate reversal (T4), and on the first postoperative day (T5). Protein electrophoresis was performed at T1 and T5. Blood cell adhesion and aggregation on fibers were analyzed with optical microscopy, and desorbed protein was evaluated quantitatively by a spectrophotometer using samples obtained when the oxygenators were dismantled after cardiopulmonary bypass.

Results. Platelet counts in group 1 demonstrated significant differences at T3, T4, and T5 (p < 0.05) versus group 2 and white blood cell counts in group 1 versus group 2, at counts T4 and T5. Albumin levels were significantly better preserved in group 1 at T4, and T5 and fibrinogen levels, at T3 and T5 (p < 0.05). On electrophoresis, the postoperative albumin level was 57.9% ± 3% in group 1 versus 50.2% ± 3% in group 2 (p < 0.05). Postoperative hemorrhage was 452 ± 35 mL in group 1 and 612 ± 35 mL in group 2 (p < 0.05). Duration of intubation was significantly lower (p < 0.05) in group 1, as was need of blood transfusion (p < 0.01). More platelet adhesion and aggregation were demonstrated on noncoated oxygenator fibers. The amount of desorbed protein was 0.13 ± 0.01 mg/dL versus 0.012 ± 0.001 mg/dL (p < 0.001) on noncoated versus coated fibers, respectively.

Conclusions. Poly(2-methoxyethylacrylate)—coated oxygenators reduce platelet adhesion, platelet aggregation and protein adsorption. This surface provides a better perioperative clinical status through platelet-, albumin-, and fibrinogen-sparing effects.




This article has been cited by other articles:


Home page
PerfusionHome page
S. Gunaydin, T. Sari, K. McCusker, U. Schonrock, and Y. Zorlutuna
Clinical evaluation of minimized extracorporeal circulation in high-risk coronary revascularization: impact on air handling, inflammation, hemodilution and myocardial function
Perfusion, May 1, 2009; 24(3): 153 - 162.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Ranucci, A. Balduini, A. Ditta, A. Boncilli, and S. Brozzi
A Systematic Review of Biocompatible Cardiopulmonary Bypass Circuits and Clinical Outcome
Ann. Thorac. Surg., April 1, 2009; 87(4): 1311 - 1319.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
S. Senay, F. Toraman, S. Gunaydin, M. Kilercik, H. Karabulut, and C. Alhan
The impact of allogenic red cell transfusion and coated bypass circuit on the inflammatory response during cardiopulmonary bypass: a randomized study
Interactive CardioVascular and Thoracic Surgery, January 1, 2009; 8(1): 93 - 99.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
J. W. Hammon
Extracorporeal Circulation: The Response of Humoral and Cellular Elements of Blood to Extracorporeal Circulation
Card. Surg. Adult, January 1, 2008; 3(2008): 370 - 389.
[Full Text]


Home page
PerfusionHome page
S. Gunaydin, K. Ayrancioglu, E. Dikmen, K. Mccusker, V. Vijay, T. Sari, T. Tezcaner, and Y. Zorlutuna
Clinical effects of leukofiltration and surface modification on post-cardiopulmonary bypass atrial fibrillation in different risk cohorts
Perfusion, July 1, 2007; 22(4): 279 - 288.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. M. Kirshbom, B. E. Miller, K. Spitzer, K. A. Easley, C. E. Spainhour, B. E. Kogon, and K. R. Kanter
Failure of surface-modified bypass circuits to improve platelet function during pediatric cardiac surgery.
J. Thorac. Cardiovasc. Surg., September 1, 2006; 132(3): 675 - 680.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. J. Kozik and J. S. Tweddell
Characterizing the Inflammatory Response to Cardiopulmonary Bypass in Children
Ann. Thorac. Surg., June 1, 2006; 81(6): S2347 - S2354.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
S. Gunaydin
Clinical significance of coated extracorporeal circuits: a review of novel technologies
Perfusion, January 1, 2004; 19(1_suppl): S33 - S41.
[Abstract] [PDF]


Home page
Card Surg AdultHome page
P. Menasche and L. H. Edmunds Jr.
Extracorporeal Circulation: The Inflammatory Response
Card. Surg. Adult, January 1, 2003; 2(2003): 349 - 360.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The Society of Thoracic Surgeons.