ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Yoshihiro Suematsu
Toshiya Ohtsuka
Takeshi Miyairi
Noboru Motomura
Shinichi Takamoto
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Suematsu, Y.
Right arrow Articles by Takamoto, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Suematsu, Y.
Right arrow Articles by Takamoto, S.
Related Collections
Right arrow Coronary disease

Ann Thorac Surg 2002;74:273-275
© 2002 The Society of Thoracic Surgeons


How to do it

Ultrasonic evaluation of graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass

Yoshihiro Suematsu, MDa*, Toshiya Ohtsuka, MDa, Takeshi Miyairi, MDa, Noboru Motomura, MDa, Shinichi Takamoto, MDa

a Department of Cardiothoracic Surgery, University of Tokyo, Tokyo, Japan

Accepted for publication April 1, 2002.

* Address reprint requests to Dr Suematsu, Department of Cardiothoracic Surgery, University of Tokyo, 7-3-1 Hongo Bunkyo-ku, Tokyo 113-8655, Japan
e-mail: suematsu{at}aurora.dti.ne.jp

Performance of the graft-to-coronary anastomosis in coronary artery bypass grafting without cardiopulmonary bypass is more difficult than conventional coronary artery bypass grafting. We report a new method that uses high-frequency epicardial echocardiography to detect technical errors and inadequacies in graft anastomoses. This method improves the operative outcome and enables detection of septal perforator branches and deeply embedded coronary arteries during coronary artery bypass grafting without cardiopulmonary bypass.




This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
C. M. Jones, T. Athanasiou, P. P. Tekkis, V. Malinovski, S. Purkayastha, A. Haq, J. Kokotsakis, and A. Darzi
Does Doppler echography have a diagnostic role in patency assessment of internal thoracic artery grafts?
Eur. J. Cardiothorac. Surg., November 1, 2005; 28(5): 692 - 700.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
T. C. Dessing, R. P.J. Budde, R. Meijer, P. F.A. Bakker, C. Borst, and P. F. Grundeman
Geometry assessment of coronary artery anastomoses with construction errors by epicardial ultrasound
Eur. J. Cardiothorac. Surg., August 1, 2004; 26(2): 257 - 261.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
L. Balacumaraswami, Y. Abu-Omar, K. Anastasiadis, B. Choudhary, D. Pigott, S.-K. Yeong, and D. P. Taggart
Does off-pump total arterial grafting increase the incidence of intraoperative graft failure?
J. Thorac. Cardiovasc. Surg., August 1, 2004; 128(2): 238 - 244.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The Society of Thoracic Surgeons.