ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Baran Sevket Ugurlu
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ugurlu, B. S.
Right arrow Articles by Oto, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ugurlu, B. S.
Right arrow Articles by Oto, O.
Related Collections
Right arrow Congenital - cyanotic

Ann Thorac Surg 2002;73:1638-1640
© 2002 The Society of Thoracic Surgeons


Case report

Pleural flap for treating perigraft leak after a modified blalock-taussig shunt

Baran Sevket Ugurlu, MD*a, Osman Nejat Sariosmanoglu, MDa, Sadik Kivanc Metin, MDa, Eyup Hazan, MDa, Oztekin Oto, MDa

a Department of Thoracic and Cardiovascular Surgery, Dokuz Eylul University Medical School, Izmir, Turkey

Accepted for publication September 7, 2001.

* Address reprint requests to Dr Ugurlu, Dokuz Eylul Universitesi Tip Fakultesi, Gogus Kalp ve Damar Cerrahisi Anabilim Dali, Balcova 35340 Izmir, Turkey
e-mail: ugurlub{at}yahoo.com

Plasa oozing through the graft after a modified Blalock-Taussig shunt is a troublesome complication. We encountered a massive leak following a modified Blalock-Taussig shunt in a 2 year-old-girl which required reexploration. The leak was treated by wrapping the polytetrafluoroethylene shunt with the parietal pleura flap harvested from the adjacent chest wall. The patient had an uneventful recovery. Covering of the polytetrafluoroethylene shunt with parietal pleura appears to stop plasma leak through the graft following a modified Blalock-Taussig shunt.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
H. T. Tevaearai, J. Schmidli, P. Mohacsi, H.-U. Rothen, F. S. Eckstein, and T. P. Carrel
Leakage of the Arterial Prosthesis of an Impella RVAD.
Ann. Thorac. Surg., October 1, 2006; 82(4): 1527 - 1529.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
A. F Corno, M. Hurni, P. Tozzi, and L. K von Segesser
Accordion-Like Prosthesis for Modified Blalock-Taussig Shunt
Asian Cardiovasc Thorac Ann, September 1, 2003; 11(3): 229 - 232.
[Abstract] [Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The Society of Thoracic Surgeons.