Background. Positioning for access to the coronary arteries leads to hemodynamic instability during off-pump cardiac surgery. External changes have been well described, but a description of the intracardiac structures in humans has not been described.
Methods. With multiplane intraoperative echocardiography, the mitral annulus at end diastole was reconstructed in the different positions and correlated with hemodynamic changes in the right heart and left atrium.
Results. Significant distortion of the mitral annulus with enlargement of the left atrium and pulmonary veins was demonstrated, which correlated with high left atrial pressures.
Conclusions. Mitral valve distortion can significantly contribute to hemodynamic instability during positioning for off-pump cardiac surgery.
This article has been cited by other articles:
![]() |
J. S. Yoo, J. B. Kim, S. H. Jung, S. J. Choo, C. H. Chung, and J. W. Lee Impact of the maze procedure and postoperative atrial fibrillation on progression of functional tricuspid regurgitation in patients undergoing degenerative mitral repair Eur J Cardiothorac Surg, March 1, 2013; 43(3): 520 - 525. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. H. Jun, J. K. Shim, J. C. Kim, and Y. L. Kwak Prognostic value of a tissue Doppler-derived index of left ventricular filling pressure on composite morbidity after off-pump coronary artery bypass surgery Br. J. Anaesth., October 1, 2011; 107(4): 519 - 524. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Kim, S. Park, H. Cho, S. Park, M. Kang, Y. Hong, and Y. Hong Haemodynamic Changes during Left Anterior Descending Artery Exposure in Off-Pump Coronary Artery Bypass: Comparison between Use of Moist Laparotomy Pads and Deep Pericardial Traction Sutures for Heart Displacement Journal of International Medical Research, August 1, 2011; 39(4): 1211 - 1218. [Abstract] [PDF] |
||||
![]() |
J. K. Shim, Y. S. Choi, D. H. Chun, S. W. Hong, D. H. Kim, and Y. L. Kwak Relationship between echocardiographic index of ventricular filling pressure and intraoperative haemodynamic changes during off-pump coronary bypass surgery Br. J. Anaesth., March 1, 2009; 102(3): 316 - 321. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. J. George, E. I. Kapetanakis, K. Dhadwal, S. Al-Ruzzeh, E. Rigopoulou, M. Bulanade, T. Athanasiou, and M. Amrani A three-dimensional echocardiographic comparison of a deep pericardial stitch versus an apical suction device for heart positioning during beating heart surgery Eur J Cardiothorac Surg, October 1, 2007; 32(4): 604 - 610. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. C. Kim, K. R. Cho, Y.-J. Kim, D.-W. Sohn, and K.-B. Kim Long-term results of the Cox-Maze III procedure for persistent atrial fibrillation associated with rheumatic mitral valve disease: 10-year experience Eur J Cardiothorac Surg, February 1, 2007; 31(2): 261 - 266. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Tabata, S. Takanashi, T. Horai, T. Fukui, and Y. Hosoda Emergency conversion in off-pump coronary artery bypass grafting Interact CardioVasc Thorac Surg, October 1, 2006; 5(5): 555 - 559. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. L. Fernandez, J. B. Garcia-Bengochea, J. Alvarez, L. F. Perez, J. M. Suarez, J. Forteza, J. Cortes, and A. Martinez Apical suction leads to severe ischemia of the ventricular apex Eur J Cardiothorac Surg, April 1, 2006; 29(4): 506 - 510. [Full Text] [PDF] |
||||
![]() |
H.-K. Kim, Y.-J. Kim, K.-I. Kim, S.-H. Jo, K.-B. Kim, H. Ahn, D.-W. Sohn, B.-H. Oh, M.-M. Lee, Y.-B. Park, et al. Impact of the Maze Operation Combined With Left-Sided Valve Surgery on the Change in Tricuspid Regurgitation Over Time Circulation, August 30, 2005; 112(9_suppl): I-14 - I-19. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Omae, Y. Kakihana, A. Mastunaga, I. Tsuneyoshi, K. Kawasaki, Y. Kanmura, and R. Sakata Hemodynamic Changes During Off-Pump Coronary Artery Bypass Anastomosis in Patients with Coexisting Mitral Regurgitation: Improvement with Milrinone Anesth. Analg., July 1, 2005; 101(1): 2 - 8. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Fiore, M. E. Latrofa, P. Tunzi, M. Traversa, C. Fondacone, N. Marraudino, L. de Luca Tupputi Schinosa, and T. Fiore Hemodynamics in off-pump surgery: normal versus compromised preoperative left ventricular function Eur J Cardiothorac Surg, March 1, 2005; 27(3): 488 - 493. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. S. Lawton, S. P. Deshpande, P. B. Zanaboni, and R. J. Damiano Jr Spontaneous Atrioventricular Groove Disruption During Off-Pump Coronary Artery Bypass Grafting Ann. Thorac. Surg., January 1, 2005; 79(1): 339 - 341. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. F. Grundeman, C. W. J. Verlaan, W. J. van Boven, and C. Borst Ninety-degree anterior cardiac displacement in off-pump coronary artery bypass grafting: the Starfish cardiac positioner preserves stroke volume and arterial pressure Ann. Thorac. Surg., August 1, 2004; 78(2): 679 - 684. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kelleher and J. Gothard Editorial II: Anaesthesia for off-pump coronary artery surgery Br. J. Anaesth., March 1, 2004; 92(3): 324 - 326. [Full Text] [PDF] |
||||
![]() |
P.-G. Chassot, P. van der Linden, M. Zaugg, X. M. Mueller, and D. R. Spahn Off-pump coronary artery bypass surgery: physiology and anaesthetic management{dagger} Br. J. Anaesth., March 1, 2004; 92(3): 400 - 413. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Al-Ruzzeh, T. Athanasiou, S. George, and M. Amrani Methodological approach in adopting off-pump coronary artery bypass surgery in a British cardiothoracic unit: Harefield experience Perfusion, January 1, 2004; 19(1_suppl): S61 - S66. [Abstract] [PDF] |
||||
![]() |
T. Athanasiou, P. Kumar, S. Al-Ruzzeh, O. Aziz, A. Charitou, J. Hart, B. Glenville, and R. Casula Expanded use of suction and stabilization devices in cardiothoracic surgery Ann. Thorac. Surg., October 1, 2003; 76(4): 1126 - 1130. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |