|
|
||||||||
Ann Thorac Surg 2002;73:1411-1417
© 2002 The Society of Thoracic Surgeons
a Bristol Heart Institute, University of Bristol, Bristol, United Kingdom
Accepted for publication December 28, 2001.
* Address reprint requests to Professor Angelini, Bristol Heart Institute, Bristol Royal Infirmary, Bristol BS2 8HW, UK
e-mail: gd.angelini{at}bristol.ac.uk
Background. This study investigated the hemodynamic changes in patients undergoing multiple vessel beating heart coronary revascularization in the presence or absence of an intracoronary shunt.
Methods. Forty patients were randomized to off-pump with a shunt (n = 20) or with the proximal coronary artery occluded by a soft snare (n = 20). Hemodynamic measurements were recorded at base line, during construction, and after completion of each distal anastomosis.
Results. Grafting of the left anterior descending coronary artery anastomosis was associated with a significant decrease in stroke volume, cardiac index, and mean arterial pressure, and an increase in pulmonary capillary wedge pressure and systemic vascular resistance in the snare but not in the shunt group. During grafting of the posterior descending coronary artery there was a marked decrease in stroke volume and cardiac index, and an increase in central venous pressure in both groups, and an increase in heart rate, mean pulmonary arterial pressure, pulmonary capillary wedge pressure, and systemic vascular resistance only in the snare group. The most extensive changes were observed during the circumflex coronary artery anastomosis with a reduction in stroke volume, cardiac index, and mean arterial pressure, and an increase in central venous pressure, pulmonary capillary wedge pressure, pulmonary arterial pressure, and systemic vascular resistance in both groups. In all settings, these changes were transient and recovered after the heart was returned to its anatomical position in the shunt group, whereas stroke volume and cardiac index remained reduced, and systemic vascular resistance was elevated in all settings in the snare group.
Conclusions. Stabilization of the left anterior descending coronary artery to perform the anastomosis resulted in temporary hemodynamic changes, which are prevented by the use of an intracoronary shunt. The hemodynamic deterioration during the construction of the posterior descending coronary artery and circumflex coronary artery anastomoses is transient in the shunt group, whereas the snaring technique is associated with an impairment of early functional recovery.
Related Article
Ann. Thorac. Surg. 2002 73: 1417.
This article has been cited by other articles:
![]() |
M. Caputo, R. R. Anis, C. A. Rogers, N. Ahmad, S. I.A. Rizvi, A. Baumbach, K. R. Karsch, G. D. Angelini, and M. Oberhoff Coronary Collateral Circulation: Effect on Early and Midterm Outcomes After Off-Pump Coronary Artery Bypass Surgery Ann. Thorac. Surg., January 1, 2008; 85(1): 71 - 79. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. P. Collison, A. Agarwal, and N. Trehan Controversies in the use of intraluminal shunts during off-pump coronary artery bypass grafting surgery. Ann. Thorac. Surg., October 1, 2006; 82(4): 1559 - 1566. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Tabata, S. Takanashi, T. Horai, T. Fukui, and Y. Hosoda Emergency conversion in off-pump coronary artery bypass grafting Interactive CardioVascular and Thoracic Surgery, October 1, 2006; 5(5): 555 - 559. [Abstract] [Full Text] [PDF] |
||||
![]() |
G.J. Murphy, C.S. Rogers, W.B. Lansdowne, I. Channon, H. Alwair, A. Cohen, M. Caputo, and G.D. Angelini Safety, efficacy, and cost of intraoperative cell salvage and autotransfusion after off-pump coronary artery bypass surgery: A randomized trial J. Thorac. Cardiovasc. Surg., July 1, 2005; 130(1): 20 - 28. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G Raja, Z. Haider, and H. Zaman Off-Pump Coronary Artery Bypass Surgery: Analysis of 5-Year Experience Asian Cardiovasc Thorac Ann, December 1, 2004; 12(4): 306 - 311. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. A Black, S. Ghosh, K. Sin, T. Spyt, and R. Pillai Off-Pump Coronary Artery Bypass Surgery Asian Cardiovasc Thorac Ann, December 1, 2004; 12(4): 379 - 386. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Yasuda, M. Okabe, M. Handa, A. Takamori, T. Suzuki, C. Kondo, and T. Nakamura New Intraluminal Coronary Shunt Tube for Off-Pump Coronary Artery Bypass Grafting Ann. Thorac. Surg., November 1, 2004; 78(5): 1814 - 1817. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. M. Nathoe, E. Buskens, E. W.L. Jansen, W. J.L. Suyker, P. R. Stella, J. R. Lahpor, W.-J. van Boven, D. van Dijk, J. C. Diephuis, C. Borst, et al. Role of Coronary Collaterals in Off-Pump and On-Pump Coronary Bypass Surgery Circulation, September 28, 2004; 110(13): 1738 - 1742. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Suzuki, M. Okabe, M. Handa, F. Yasuda, and Y. Miyake Usefulness of preoperative intraaortic balloon pump therapy during off-pump coronary artery bypass grafting in high-risk patients Ann. Thorac. Surg., June 1, 2004; 77(6): 2056 - 2059. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. B. Hangler, K. Pfaller, E. Ruttmann, D. Hoefer, T. Schachner, G. Laufer, and H. Antretter Effects of intracoronary shunts on coronary endothelial coating in the human beating heart Ann. Thorac. Surg., March 1, 2004; 77(3): 776 - 780. [Abstract] [Full Text] [PDF] |
||||
![]() |
P.-G. Chassot, P. van der Linden, M. Zaugg, X. M. Mueller, and D. R. Spahn Off-pump coronary artery bypass surgery: physiology and anaesthetic management{dagger} Br. J. Anaesth., March 1, 2004; 92(3): 400 - 413. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Calafiore, M. Di Mauro, C. Canosa, G. Di Giammarco, A. L. Iaco, and M. Contini Myocardial revascularization with and without cardiopulmonary bypass: advantages, disadvantages and similarities Eur. J. Cardiothorac. Surg., December 1, 2003; 24(6): 953 - 960. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Suzuki, M. Okabe, F. Yasuda, Y. Miyake, M. Handa, and T. Nakamura Our experiences for off-pump coronary artery bypass grafting to the circumflex system Ann. Thorac. Surg., December 1, 2003; 76(6): 2013 - 2016. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. L. Ngaage Off-pump coronary artery bypass grafting: the myth, the logic and the science Eur. J. Cardiothorac. Surg., October 1, 2003; 24(4): 557 - 570. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Hilker, H. Oelert, and U. Hake A review of 507 off-pump coronary bypass patients: a single center experience Interactive CardioVascular and Thoracic Surgery, September 1, 2003; 2(3): 246 - 250. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. Hart Maintaining hemodynamic stability and myocardial performance during off-pump coronary bypass surgery Ann. Thorac. Surg., February 1, 2003; 75(2): S740 - 744. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |