ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Stephen Westaby
Satoshi Saito
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Westaby, S.
Right arrow Articles by Jarvik, R. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Westaby, S.
Right arrow Articles by Jarvik, R. K.
Related Collections
Right arrow Mechanical Circulatory Assistance

Ann Thorac Surg 2002;73:1337-1340
© 2002 The Society of Thoracic Surgeons


How to do it

Implant technique for the Jarvik 2000 heart

Stephen Westaby, PhD, FETCS*a, O.H. Frazier, MDb, David W. Pigott, FRCAa, Satoshi Saito, MD, PhDa, Robert K. Jarvik, MDc,1

a Oxford Heart Centre and The Heart Hospital, London, United Kingdom
b Texas Heart Institute, Houston, Texas, USA
c Jarvik Heart Inc, New York, New York, USA

Accepted for publication December 3, 2001.

* Address reprint requests to Dr Westaby, Oxford Heart Centre, John Radcliffe Hospital, Headley Way, Headington, Oxford OX3 9DU, United Kingdom
e-mail: swestaby{at}ahf.org.uk

The Jarvik 2000 Heart is a silent compact axial flow impeller pump which is now undergoing clinical trials for both bridge to transplantation and permanent mechanical circulatory support. The pump is implanted into the apex of the failing left ventricle by left thoracotomy. A vascular graft offloads to the descending thoracic aorta so that only the left pleural cavity is opened. Power supply is through an abdominal drive line or post-auricular titanium pedestal according to the treatment strategy.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
T. Komoda, Y. Weng, and R. Hetzer
Technique for Insertion of the Inflow Cannula of the INCOR Left Ventricular Assist Device
Ann. Thorac. Surg., April 1, 2008; 85(4): 1466 - 1467.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. C. Anyanwu, G. W. Fischer, I. Plotkina, S. Pinney, and D. H. Adams
Off-Pump Implant of the Jarvik 2000 Ventricular Assist Device Through Median Sternotomy
Ann. Thorac. Surg., October 1, 2007; 84(4): 1405 - 1407.
[Abstract] [Full Text] [PDF]


Home page
Anesth. Analg.Home page
S. Chumnanvej, M. J. Wood, T. E. MacGillivray, and M. F. V. Melo
Perioperative Echocardiographic Examination for Ventricular Assist Device Implantation
Anesth. Analg., September 1, 2007; 105(3): 583 - 601.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
E. D. Feller, E. N. Sorensen, M. Haddad, R. N. Pierson, F. L. Johnson, J. M. Brown, and B. P. Griffith
Clinical Outcomes Are Similar in Pulsatile and Nonpulsatile Left Ventricular Assist Device Recipients
Ann. Thorac. Surg., March 1, 2007; 83(3): 1082 - 1088.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart JHome page
M. P. Siegenthaler, S. Westaby, O.H. Frazier, J. Martin, A. Banning, D. Robson, J. Pepper, P. Poole-Wilson, and F. Beyersdorf
Advanced heart failure: feasibility study of long-term continuous axial flow pump support
Eur. Heart J., May 2, 2005; 26(10): 1031 - 1038.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
O.H. Frazier, T. J. Myers, and I. Gregoric
Biventricular assistance with the Jarvik FlowMaker: A case report
J. Thorac. Cardiovasc. Surg., October 1, 2004; 128(4): 625 - 626.
[Full Text] [PDF]


Home page
HeartHome page
J J Bax, E E van der Wall, and M Harbinson
Radionuclide techniques for the assessment of myocardial viability and hibernation
Heart, August 1, 2004; 90(suppl_5): v26 - v33.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
O. H. Frazier, T. J. Myers, S. Westaby, and I. D. Gregoric
Clinical experience with an implantable, intracardiac, continuous flow circulatory support device: physiologic implications and their relationship to patient selection
Ann. Thorac. Surg., January 1, 2004; 77(1): 133 - 142.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. V. Letsou, T. J. Myers, I. D. Gregoric, R. Delgado, N. Shah, K. Robertson, B. Radovancevic, and O. H. Frazier
Continuous axial-flow left ventricular assist device (Jarvik 2000) maintains kidney and liver perfusion for up to 6 months
Ann. Thorac. Surg., October 1, 2003; 76(4): 1167 - 1170.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. J. Myers, K. Robertson, T. Pool, N. Shah, I. Gregoric, and O. H. Frazier
Continuous flow pumps and total artificial hearts: management issues
Ann. Thorac. Surg., June 1, 2003; 75(90060): S79 - 85.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
M.P. Siegenthaler, J. Martin, K. Pernice, T. Doenst, S. Sorg, G. Trummer, O. Friesewinkel, and F. Beyersdorf
The Jarvik 2000 is associated with less infections than the HeartMate left ventricular assist device
Eur. J. Cardiothorac. Surg., May 1, 2003; 23(5): 748 - 755.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The Society of Thoracic Surgeons.