ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Erik Fosse
Runar Lundblad
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Hol, P. K.
Right arrow Articles by Smith, H.-J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Hol, P. K.
Right arrow Articles by Smith, H.-J.
Related Collections
Right arrowRelated Article

Ann Thorac Surg 2002;73:813-818
© 2002 The Society of Thoracic Surgeons


Original article: cardiovascular

The importance of intraoperative angiographic findings for predicting long-term patency in coronary artery bypass operations

Per K. Hol, MD*a, Erik Fosse, MD, PhDa, Runar Lundblad, MD, PhDb, Sigurd Nitter-Hauge, MD, PhDc, Paulina Due-Tønnessen, MDd, Karleif Vatne, MDd, Hans-Jørgen Smith, MD, PhDd

a The Interventional Centre University of Oslo, Oslo, Norway
b Department of Thoracic Surgery Rikshospitalet, University of Oslo, Oslo, Norway
c Department of Cardiology Rikshospitalet, University of Oslo, Oslo, Norway
d Department of Radiology, Rikshospitalet, University of Oslo, Oslo, Norway

Accepted for publication November 1, 2001.

* Address reprint requests to Dr Hol, The Interventional Centre, Rikshospitalet, N-0027 Oslo, Norway
e-mail: per.kristian.hol{at}rikshospitalet.no

Background. The quality of anastomosis is the cornerstone in coronary artery bypass operations. Intraoperative coronary angiography confirms graft patency with the possibility to revise graft failure. The aim of this study was to describe the lesions found at "on-table" angiography, and to evaluate the significance of these immediate angiographic findings for the long-term patency.

Methods. A total of 57 grafts (42 left internal mammary artery grafts and 15 saphenous vein grafts) in 45 patients who underwent off-pump coronary artery bypass operations were included. On-table angiography was carried out with fixed angiographic equipment installed in the operating room. Follow-up angiographies were performed at 3 months and at 12 months.

Results. The most frequent finding in an on-table angiogram was spasm, which was not present at follow-up. Out of nine kinks, only one developed into a significant stenosis at follow-up. Of 44 grafts that were normal on-table, 37 (84%) were normal at the follow-up. Of 11 grafts with significant lesions on-table, eight (73%) were normal at the follow-up. Five percent of the grafts were revised because of the on-table angiography.

Conclusions. On-table angiograms can be occasionally difficult to interpret because not all findings are important for later patency. Optimal results on-table predict good long-term results with a negative predictive value of 0.84, whereas significant lesions on-table have less impact on the follow-up results because the positive predictive value was only 0.38.


Related Article

Invited commentary
Anthony P.C. Yim and Song Wan
Ann. Thorac. Surg. 2002 73: 818. [Extract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
L. Balacumaraswami, Y. Abu-Omar, J. Selvanayagam, D. Pigott, and D. P. Taggart
The effects of on-pump and off-pump coronary artery bypass grafting on intraoperative graft flow in arterial and venous conduits defined by a flow/pressure ratio
J. Thorac. Cardiovasc. Surg., March 1, 2008; 135(3): 533 - 539.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. K. Hol, K. Andersen, H. Skulstad, P. S. Halvorsen, P. S. Lingaas, R. Andersen, J. Bergsland, and E. Fosse
Epicardial Ultrasonography: A Potential Method for Intraoperative Quality Assessment of Coronary Bypass Anastomoses?
Ann. Thorac. Surg., September 1, 2007; 84(3): 801 - 807.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. S. Lingaas, P. K. Hol, R. Lundblad, K. A. Rein, L. Mathisen, H.-J. Smith, R. Andersen, E. Thaulow, T. I. Tonnesen, J. L. Svennevig, et al.
Clinical and Radiologic Outcome of Off-Pump Coronary Surgery at 12 Months Follow-Up: A Prospective Randomized Trial
Ann. Thorac. Surg., June 1, 2006; 81(6): 2089 - 2095.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
R. P.J. Budde, W. J.L. Suyker, P. T.W. Suyker, C. W.J. Verlaan, R. Meijer, C. Borst, and P. F. Grundeman
Quality assessment of distal S2AS connector anastomosis by 13MHz epicardial ultrasound
Eur. J. Cardiothorac. Surg., December 1, 2005; 28(6): 833 - 837.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Lund, K. Sundet, B. Tennoe, P. K. Hol, K. A. Rein, E. Fosse, and D. Russell
Cerebral Ischemic Injury and Cognitive Impairment After Off-Pump and On-Pump Coronary Artery Bypass Grafting Surgery
Ann. Thorac. Surg., December 1, 2005; 80(6): 2126 - 2131.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
K. Orihashi, T. Sueda, K. Okada, and K. Imai
Left Internal Thoracic Artery Graft Assessed by Means of Intraoperative Transesophageal Echocardiography
Ann. Thorac. Surg., February 1, 2005; 79(2): 580 - 584.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
R. P.J. Budde, T. C. Dessing, R. Meijer, P. F.A. Bakker, C. Borst, and P. F. Grundeman
Robot-assisted 13 MHz epicardial ultrasound for endoscopic quality assessment of coronary anastomoses
Interactive CardioVascular and Thoracic Surgery, December 1, 2004; 3(4): 616 - 620.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. K. Hol, P. S. Lingaas, R. Lundblad, K. A. Rein, K. Vatne, H.-J. Smith, S. Nitter-Hauge, and E. Fosse
Intraoperative angiography leads to graft revision in coronary artery bypass surgery
Ann. Thorac. Surg., August 1, 2004; 78(2): 502 - 505.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
L. Balacumaraswami, Y. Abu-Omar, K. Anastasiadis, B. Choudhary, D. Pigott, S.-K. Yeong, and D. P. Taggart
Does off-pump total arterial grafting increase the incidence of intraoperative graft failure?
J. Thorac. Cardiovasc. Surg., August 1, 2004; 128(2): 238 - 244.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The Society of Thoracic Surgeons.