|
|
||||||||
Ann Thorac Surg 2002;73:813-818
© 2002 The Society of Thoracic Surgeons
a The Interventional Centre University of Oslo, Oslo, Norway
b Department of Thoracic Surgery Rikshospitalet, University of Oslo, Oslo, Norway
c Department of Cardiology Rikshospitalet, University of Oslo, Oslo, Norway
d Department of Radiology, Rikshospitalet, University of Oslo, Oslo, Norway
Accepted for publication November 1, 2001.
* Address reprint requests to Dr Hol, The Interventional Centre, Rikshospitalet, N-0027 Oslo, Norway
e-mail: per.kristian.hol{at}rikshospitalet.no
Background. The quality of anastomosis is the cornerstone in coronary artery bypass operations. Intraoperative coronary angiography confirms graft patency with the possibility to revise graft failure. The aim of this study was to describe the lesions found at "on-table" angiography, and to evaluate the significance of these immediate angiographic findings for the long-term patency.
Methods. A total of 57 grafts (42 left internal mammary artery grafts and 15 saphenous vein grafts) in 45 patients who underwent off-pump coronary artery bypass operations were included. On-table angiography was carried out with fixed angiographic equipment installed in the operating room. Follow-up angiographies were performed at 3 months and at 12 months.
Results. The most frequent finding in an on-table angiogram was spasm, which was not present at follow-up. Out of nine kinks, only one developed into a significant stenosis at follow-up. Of 44 grafts that were normal on-table, 37 (84%) were normal at the follow-up. Of 11 grafts with significant lesions on-table, eight (73%) were normal at the follow-up. Five percent of the grafts were revised because of the on-table angiography.
Conclusions. On-table angiograms can be occasionally difficult to interpret because not all findings are important for later patency. Optimal results on-table predict good long-term results with a negative predictive value of 0.84, whereas significant lesions on-table have less impact on the follow-up results because the positive predictive value was only 0.38.
Related Article
Ann. Thorac. Surg. 2002 73: 818.
This article has been cited by other articles:
![]() |
L. Balacumaraswami, Y. Abu-Omar, J. Selvanayagam, D. Pigott, and D. P. Taggart The effects of on-pump and off-pump coronary artery bypass grafting on intraoperative graft flow in arterial and venous conduits defined by a flow/pressure ratio J. Thorac. Cardiovasc. Surg., March 1, 2008; 135(3): 533 - 539. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. K. Hol, K. Andersen, H. Skulstad, P. S. Halvorsen, P. S. Lingaas, R. Andersen, J. Bergsland, and E. Fosse Epicardial Ultrasonography: A Potential Method for Intraoperative Quality Assessment of Coronary Bypass Anastomoses? Ann. Thorac. Surg., September 1, 2007; 84(3): 801 - 807. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. S. Lingaas, P. K. Hol, R. Lundblad, K. A. Rein, L. Mathisen, H.-J. Smith, R. Andersen, E. Thaulow, T. I. Tonnesen, J. L. Svennevig, et al. Clinical and Radiologic Outcome of Off-Pump Coronary Surgery at 12 Months Follow-Up: A Prospective Randomized Trial Ann. Thorac. Surg., June 1, 2006; 81(6): 2089 - 2095. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. P.J. Budde, W. J.L. Suyker, P. T.W. Suyker, C. W.J. Verlaan, R. Meijer, C. Borst, and P. F. Grundeman Quality assessment of distal S2AS connector anastomosis by 13MHz epicardial ultrasound Eur. J. Cardiothorac. Surg., December 1, 2005; 28(6): 833 - 837. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Lund, K. Sundet, B. Tennoe, P. K. Hol, K. A. Rein, E. Fosse, and D. Russell Cerebral Ischemic Injury and Cognitive Impairment After Off-Pump and On-Pump Coronary Artery Bypass Grafting Surgery Ann. Thorac. Surg., December 1, 2005; 80(6): 2126 - 2131. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Orihashi, T. Sueda, K. Okada, and K. Imai Left Internal Thoracic Artery Graft Assessed by Means of Intraoperative Transesophageal Echocardiography Ann. Thorac. Surg., February 1, 2005; 79(2): 580 - 584. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. P.J. Budde, T. C. Dessing, R. Meijer, P. F.A. Bakker, C. Borst, and P. F. Grundeman Robot-assisted 13 MHz epicardial ultrasound for endoscopic quality assessment of coronary anastomoses Interactive CardioVascular and Thoracic Surgery, December 1, 2004; 3(4): 616 - 620. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. K. Hol, P. S. Lingaas, R. Lundblad, K. A. Rein, K. Vatne, H.-J. Smith, S. Nitter-Hauge, and E. Fosse Intraoperative angiography leads to graft revision in coronary artery bypass surgery Ann. Thorac. Surg., August 1, 2004; 78(2): 502 - 505. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. Balacumaraswami, Y. Abu-Omar, K. Anastasiadis, B. Choudhary, D. Pigott, S.-K. Yeong, and D. P. Taggart Does off-pump total arterial grafting increase the incidence of intraoperative graft failure? J. Thorac. Cardiovasc. Surg., August 1, 2004; 128(2): 238 - 244. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |