ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Paul P. Urbanski
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Urbanski, P. P.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Urbanski, P. P.
Related Collections
Right arrow Great vessels
Right arrowRelated Article

Ann Thorac Surg 2002;73:725-728
© 2002 The Society of Thoracic Surgeons


Original article: cardiovascular

Complete aortic root replacement in patients with small aortic annulus

Paul P. Urbanski, MD*a

a Herz- und Gefaess-Klinik, Bad Neustadt, Germany

Accepted for publication October 20, 2001.

* Address reprint requests to Dr Urbanski, Herz- und Gefaess-Klinik, Salzburger Leite 1, 97616 Bad Neustadt, Germany
e-mail: urbanski{at}kardiochirurg.de

Background. We evaluated the effectiveness of our surgical method using a modified self-assembled valved composite graft in patients with a narrow aortic annulus.

Methods. Between August 2000 and May 2001, 10 consecutive patients with a narrow aortic annulus underwent replacement of the aortic valve and the ascending aorta using a valved composite graft with mechanical valve prosthesis. The indication for surgery was aneurysm of the ascending aorta (8 patients) and aortic dissection (2 patients). To avoid valve-patient mismatch, a modified self-assembled valved composite graft was used.

Results. There was no hospital mortality. Echocardiographic evaluation before discharge showed excellent hemodynamics with a mean transvalvular gradient of 10.7 mm Hg (standard deviation ± 2.8 mm Hg).

Conclusions. The described valved composite graft offers very good hemodynamic performance and is a simple and effective device to avoid valve-patient mismatch in patients with a small aortic annulus who need aortic root replacement.


Related Article

Invited commentary
Lars G. Svensson
Ann. Thorac. Surg. 2002 73: 728-729. [Extract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
Asian Cardiovasc. Thorac. Ann.Home page
P. P Urbanski, W. Dinstak, S. Frank, A. Siebel, and R. W Hacker
Modified versus Standard Mechanical Valved Aortic Conduit
Asian Cardiovasc Thorac Ann, March 1, 2005; 13(1): 53 - 57.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Ruel, F. D. Rubens, R. G. Masters, A. L. Pipe, P. Bedard, P. J. Hendry, B. K. Lam, I. G. Burwash, W. G. Goldstein, M. P. Brais, et al.
Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves
J. Thorac. Cardiovasc. Surg., January 1, 2004; 127(1): 149 - 159.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
P. P. Urbanski
Cannulation of the left common carotid artery for proximal aortic repair
J. Thorac. Cardiovasc. Surg., September 1, 2003; 126(3): 887 - 888.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The Society of Thoracic Surgeons.