ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Luckraz, H.
Right arrow Articles by Large, S. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Luckraz, H.
Right arrow Articles by Large, S. R.
Related Collections
Right arrow Mechanical Circulatory Assistance

Ann Thorac Surg 2002;73:546-548
© 2002 The Society of Thoracic Surgeons


Original article: cardiovascular

And hemolysis goes on: ventricular assist device in combination with veno-venous hemofiltration

Heyman Luckraz, FRCS*a, Michael Woods, RGNa, Stephen R. Large, FRCSa The Papworth VAD Group,a

a The Transplant Unit, Papworth Hospital, Papworth Everard, Cambridgeshire, United Kingdom

Accepted for publication September 13, 2001.

* Address reprint requests to Mr Luckraz, The Transplant Unit, Papworth Hospital, Papworth Everard, Cambridgeshire CB3 8RE, UK
e-mail: heyman.luckraz{at}papworth-tr.anglox.nhs.uk

Background. Ventricular Assist Device (VAD) is an accepted treatment as a bridge to cardiac transplantation, and may be of help in patients as destination therapy for end-stage cardiac failure. The low output state associated with end-stage cardiac failure predisposes patients to renal dysfunction and the need for short-term renal support. The use of cardiopulmonary bypass for VAD insertion, VAD, and hemofiltration expose the blood to mechanical trauma and activated inflammatory cascades that can result in hemolysis. This produces free hemoglobin, a known nephrotoxin; this is a further renal insult. This study assesses the effect of VAD alone and in combination with continuous veno-venous hemofiltration (CVVHF) on hemolysis.

Methods and Results. From July 1999 to December 2000, Thoratec VAD was used in 11 patients. Nine (all males) were included in this study as all had laboratory profiles. Hemolysis was quantified by plasma free hemoglobin (PFHb) and hydroxybuterate dehydrogenase (HBD) levels measured daily, defined as PFHb level greater than 40 mg/L and HBD greater than 250 IU/L. Data relate to the following time intervals while the VAD was still in situ: T1 = 24 hours post-VAD insertion, T2 = 24 hours post-CVVHF start, T3 = 48 to 72 hours with the same CVVHF circuit, T4 = 24 hours post-stopping of CVVHF, and T5 = CVVHF off for over 48 hours. The mean (SD) PFHb levels were 19.6 (10.9) at T1, 31.7 (0.6) at T2, 93.7 (16.4) at T3 (p < 0.05), 32.5 (20.9) at T4, and 14.2 (3.8) at T5 (p < 0.05). These changes were paralleled by the mean (SD) HBD levels: T1 = 1,337 (616), T2 = 2,025 (509), T3 = 2,676 (1,170) (p < 0.05), T4 1,780 (618), and T5 = 1,310 (436).

Conclusions. Thoratec VAD was associated with a mild degree of hemolysis. This was worsened by concomitant use of CVVHF. The effect was accentuated if the same CVVHF circuit was used for over 48 hours but was reversible within 24 hours of stopping the hemofilter.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
L. E. Samuels, E. C. Holmes, P. Garwood, and F. Ferdinand
Initial Experience With the Abiomed AB5000 Ventricular Assist Device System
Ann. Thorac. Surg., July 1, 2005; 80(1): 309 - 312.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2002 by The Society of Thoracic Surgeons.