Ann Thorac Surg 2002;73:444-448
© 2002 The Society of Thoracic Surgeons
a Department of Cardiovascular Surgery, Hiroshima City Asa Hospital, Hiroshima, Japan
Accepted for publication August 7, 2001.
* Address reprint requests to Dr Uchida, Department of Cardiovascular Surgery, Hiroshima City Asa Hospital, Kabe-minami, Asakita-Ku, Hiroshima-City, Hiroshima, 731-0223, Japan
e-mail: cvgeka{at}asa-hosp.city.hiroshima.jp
Background. The late results of direct open stent grafting of the aortic arch for aortic arch repair have not been reported previously.
Methods. Between September 1997 and December 2000, 19 patients underwent open stent grafting with carotid artery bypass for thoracic arteriosclerotic aneurysms (TAA) of the distal aortic arch. In addition, 21 patients underwent open stent grafting with total aortic arch replacement for Stanford type A acute aortic dissection and 7 patients underwent stenting with carotid bypass for Stanford type B chronic aortic dissection.
Results. The early mortality rate was 11% for TAA, 10% for type A dissection, and 0% for type B dissection. Whereas none of the TAA or type A dissection required a second operation on the thoracic aorta, 1 TAA patient died 6 months postoperatively after sudden aortic rupture and 1 type B patient required descending aortic replacement because of ulceration caused by the stent graft at 11 months postoperatively. On follow-up computed tomography scan, in TAA patients, true aneurysms excluded by the stent graft showed early thrombosis, but the absorption of thrombosed aneurysms started from 1 to 6 months postoperatively and gradually progressed. In patients with type B chronic dissection, the false lumen showed early thrombosis and the true lumen was dilated at the central portion of the graft, which might increase turbulent flow by interaction with the stent. In patients with type A acute dissection, the false lumen showed both early thrombosis and early absorption.
Conclusions. Early and late results of open stenting are acceptable and follow-up computed tomography scan may be able to predict late results of open stenting.
Related Article
Ann. Thorac. Surg. 2002 73: 449.
This article has been cited by other articles:
![]() |
N. Uchida, H. Shibamura, A. Katayama, N. Shimada, M. Sutoh, and H. Ishihara Operative strategy for acute type a aortic dissection: ascending aortic or hemiarch versus total arch replacement with frozen elephant trunk. Ann. Thorac. Surg., March 1, 2009; 87(3): 773 - 777. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Uchida, H. Shibamura, A. Katayama, N. Shimada, and M. Sutoh Total arch replacement with an open stent graft for acute type A aortic dissection: fate of the false lumen Eur. J. Cardiothorac. Surg., January 1, 2009; 35(1): 83 - 88. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Uchida, H. Shibamura, A. Katayama, K. Aishin, M. Sutoh, and M. Kuraoka Surgical strategies for organ malperfusions in acute type B aortic dissection Interactive CardioVascular and Thoracic Surgery, January 1, 2009; 8(1): 75 - 78. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. Uchida, H. Ishihara, H. Shibamura, Y. Kyo, and M. Ozawa Midterm results of extensive primary repair of the thoracic aorta by means of total arch replacement with open stent graft placement for an acute type A aortic dissection J. Thorac. Cardiovasc. Surg., April 1, 2006; 131(4): 862 - 867. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Flores, T. Kunihara, N. Shiiya, K. Yoshimoto, K. Matsuzaki, and K. Yasuda Extensive deployment of the stented elephant trunk is associated with an increased risk of spinal cord injury J. Thorac. Cardiovasc. Surg., February 1, 2006; 131(2): 336 - 342. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Shibata, H. Hirai, T. Fukui, T. Aoyama, and S. Suehiro Assembly and Deployment of a Branched Arch Stent Graft Using the Transaortic Approach Ann. Thorac. Surg., May 1, 2005; 79(5): 1790 - 1792. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Pocar, P. Fundaro, and F. Donatelli Simplified thoracic aortic aneurysm repair Ann. Thorac. Surg., June 1, 2004; 77(6): 2199 - 2200. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Sueda, K. Orihashi, K. Okada, Y. Sugawara, K. Imai, and M. Hamamoto Successful shrinkage of distal arch and proximal descending aortic aneurysm after transaortic endovascular stent-grafting Eur. J. Cardiothorac. Surg., May 1, 2004; 25(5): 716 - 721. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Sueda, K. Orihashi, K. Okada, Y. Sugawara, K. Imai, and K. Kochi Fate of aneurysms of the distal arch and proximal descending thoracic aorta after transaortic endovascular Stent-Grafting Ann. Thorac. Surg., July 1, 2003; 76(1): 84 - 89. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. Beaver and T. D. Martin Reply Ann. Thorac. Surg., October 1, 2002; 74(4): 1293 - 1293. [Full Text] [PDF] |
||||