ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Paul F. Gründeman
Cornelius Borst
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Gründeman, P. F.
Right arrow Articles by Mertens, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Gründeman, P. F.
Right arrow Articles by Mertens, S.
Related Collections
Right arrow Minimally invasive surgery

Ann Thorac Surg 2001;72:1991-1996
© 2001 The Society of Thoracic Surgeons


Original article: cardiovascular

Hemodynamic changes with right lateral decubitus body positioning in the tilted porcine heart

Paul F. Gründeman, MD, PhD*a, Cornelius Borst, MD, PhDa, Cees W.J. Verlaana, Stefan Damen, MDa, Sabine Mertens, MDa

a Heart Lung Center Utrecht, University Medical Center, Utrecht, The Netherlands

Accepted for publication July 16, 2001.

* Address reprint requests to Dr Gründeman, Experimental Cardiology Laboratory, Heart Lung Institute, Utrecht University Medical Center (Room G02.523), PO Box 85500, 3508 GA Utrecht, The Netherlands
e-mail: exp.cardio{at}hli.azu.nl

Background. In beating-heart coronary surgical procedures, exposure of posterior vessels through sternotomy causes cardiac function to deteriorate. We hypothesized that turning the subject to the right lateral decubitus position before cardiac retraction improves exposure of posterior vessels and preserves cardiac pump function on displacement.

Methods. Eight 80-kg open-chest pigs were instrumented with catheter-tip manometers. After a stepwise 60-degree turn to the right lateral decubitus position of the body, the heart was retracted anteriorly to 90 degrees with a suction stabilizer.

Results. Right lateral body positioning caused an approximately 45-degree right deviation of the apex, thereby exposing the left atrial groove. Stroke volume, mean arterial pressure, right atrial pressure, and right ventricular end-diastolic pressure increased to 106% ± 5% (mean ± standard error of the mean, p = 0.31), 106% ± 3% (p = 0.01), 129% ± 8% (p = 0.001), and 171% ± 14% (p = 0.002), respectively, compared with control values. In contrast, left atrial pressure decreased to 73% ± 6% (p = 0.007), whereas left ventricular preload remained unchanged (110% ± 8%, p = 0.26). Additional anterior displacement to 90 degrees fully exposed the posterior vessels, and stroke volume decreased to 90% ± 3% (p = 0.01) and mean arterial pressure to 93% ± 5% (p = 0.07) at the expense of further increased right ventricular preload (256% ± 28%, p < 0.001).

Conclusions. By placing the subject in the right lateral decubitus position, exposure through sternotomy of posterior vessels in the beating porcine heart was facilitated while mean arterial pressure was maintained.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
P. F. Grundeman, C. W. J. Verlaan, W. J. van Boven, and C. Borst
Ninety-degree anterior cardiac displacement in off-pump coronary artery bypass grafting: the Starfish cardiac positioner preserves stroke volume and arterial pressure
Ann. Thorac. Surg., August 1, 2004; 78(2): 679 - 684.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. P. Talpahewa, R. Ascione, G. D. Angelini, and A. T. Lovell
Cerebral cortical oxygenation changes during OPCAB surgery
Ann. Thorac. Surg., November 1, 2003; 76(5): 1516 - 1522.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. C. Hart
Maintaining hemodynamic stability and myocardial performance during off-pump coronary bypass surgery
Ann. Thorac. Surg., February 1, 2003; 75(2): S740 - 744.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2001 by The Society of Thoracic Surgeons.