ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Ochi, M.
Right arrow Articles by Honma, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Ochi, M.
Right arrow Articles by Honma, H.
Related Collections
Right arrow Coronary disease

Ann Thorac Surg 2001;71:1210-1214
© 2001 The Society of Thoracic Surgeons


Original article: cardiovascular

Limited flow capacity of the right gastroepiploic artery graft: postoperative echocardiographic and angiographic evaluation

Masami Ochi, MDa, Nobuo Hatori, MD, PhDa, Masahiro Fujii, MDa, Yoshiaki Saji, MDa, Shigeo Tanaka, MDa, Hiroshi Honma, MDb

a Department of Surgery II, Division of Cardiovascular Surgery, Nippon Medical School, Tokyo, Japan
b Department of Internal Medicine I, Nippon Medical School, Tokyo, Japan

Accepted for publication November 28, 2000.

Address reprint requests to Dr Ochi, 1-1-5 Sendagi Bunkyo-ku, Tokyo, 113-8603, Japan
e-mail: ochi/surg2{at}nms.ac.jp

Background. The flow capacity of the right gastroepiploic artery graft has not been clarified.

Methods. Angiographic and echocardiographic studies were conducted in 30 patients who had undergone coronary artery bypass grafting using both the internal thoracic and right gastroepiploic arteries. The luminal diameter of the arterial grafts was measured from the postoperative angiograms. The adequacy of the myocardial blood supply from the arterial grafts was evaluated by dobutamine stress echocardiography.

Results. With echocardiography, 14 patients exhibited an ischemic response in the gastroepiploic artery grafted region, whereas no patients exhibited an ischemic response in the internal thoracic artery grafted area. The luminal diameter of the gastroepiploic artery and a younger age were correlated with the ischemic response observed in the dobutamine stress echocardiography. A luminal diameter of the gastroepiploic artery of greater than 2.6 mm had the highest sensitivity and specificity for a nonischemic change.

Conclusions. To generate the maximal flow reserve, the luminal diameter of the gastroepiploic artery when used as a graft should be sufficiently large enough, nearly 3 mm at the anastomosis.




This article has been cited by other articles:


Home page
J Am Coll CardiolHome page
D. Glineur, W. D'hoore, G. El Khoury, S. Sondji, G. Kalscheuer, J.-C. Funken, J. Rubay, A. Poncelet, P. Astarci, R. Verhelst, et al.
Angiographic Predictors of 6-Month Patency of Bypass Grafts Implanted to the Right Coronary Artery: A Prospective Randomized Comparison of Gastroepiploic Artery and Saphenous Vein Grafts
J. Am. Coll. Cardiol., January 15, 2008; 51(2): 120 - 125.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Minakawa, I. Fukuda, M. Wada, J. Kaiqiang, K. Daitoku, K. Itoh, and K. Fukui
Preoperative evaluation of the right gastroepiploic artery using abdominal ultrasonography.
Ann. Thorac. Surg., September 1, 2006; 82(3): 1131 - 1133.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Mizukami, T. Sueda, H. Wada, K. Imai, M. Hamamoto, and D. Futagami
Right Gastroepiploic Artery Grafting for Saphenous Vein Graft Pseudoaneurysm
Ann. Thorac. Surg., August 1, 2006; 82(2): 742 - 744.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
K.-B. Kim, K. R. Cho, J.-S. Choi, and H.-J. Lee
Right Gastroepiploic Artery for Revascularization of the Right Coronary Territory in Off-Pump Total Arterial Revascularization: Strategies to Improve Patency
Ann. Thorac. Surg., June 1, 2006; 81(6): 2135 - 2141.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S.-W. Ryu, B.-H. Ahn, S.-J. Choo, K.-J. Na, Y.-K. Ahn, M.-H. Jeong, and S.-H. Kim
Skeletonized Gastroepiploic Artery as a Composite Graft for Total Arterial Revascularization
Ann. Thorac. Surg., July 1, 2005; 80(1): 118 - 123.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Shimizu, H. Suesada, M. Cho, S. Ito, K. Ikeda, and S. Ishimaru
Flow Capacity of Gastroepiploic Artery Versus Vein Grafts for Intermediate Coronary Artery Stenosis
Ann. Thorac. Surg., July 1, 2005; 80(1): 124 - 130.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. Pevni, G. Uretzky, P. Yosef, B. Gal Yanay, I. Shapira, N. Nesher, R. Braunshtein, and R. Mohr
Revascularization of the Right Coronary Artery in Bilateral Internal Thoracic Artery Grafting
Ann. Thorac. Surg., February 1, 2005; 79(2): 564 - 569.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
F. Formica, O. Ferro, P. Greco, A. Martino, D. Gastaldi, and G. Paolini
Long-term follow-up of total arterial myocardial revascularization using exclusively pedicle bilateral internal thoracic artery and right gastroepiploic artery
Eur. J. Cardiothorac. Surg., December 1, 2004; 26(6): 1141 - 1148.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Kamiya, G. Watanabe, H. Takemura, S. Tomita, H. Nagamine, and T. Kanamori
Skeletonization of gastroepiploic artery graft in off-pump coronary artery bypass grafting: early clinical and angiographic assessment
Ann. Thorac. Surg., June 1, 2004; 77(6): 2046 - 2050.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
H. Kamiya, G. Watanabe, H. Takemura, S. Tomita, H. Nagamine, and T. Kanamori
Total arterial revascularization with composite skeletonized gastroepiploic artery graft in off-pump coronary artery bypass grafting
J. Thorac. Cardiovasc. Surg., April 1, 2004; 127(4): 1151 - 1157.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. Tatoulis, B. F. Buxton, and J. A. Fuller
Patencies of 2,127 arterial to coronary conduits over 15 years
Ann. Thorac. Surg., January 1, 2004; 77(1): 93 - 101.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
O. Lev-Ran, R. Mohr, G. Uretzky, D. Pevni, C. Locker, Y. Paz, and I. Shapira
Graft of choice to right coronary system in left-sided bilateral internal thoracic artery grafting
Ann. Thorac. Surg., January 1, 2003; 75(1): 88 - 92.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Ochi, N. Hatori, R. Bessho, M. Fujii, Y. Saji, S. Tanaka, and H. Honma
Adequacy of flow capacity of bilateral internal thoracic artery T graft
Ann. Thorac. Surg., December 1, 2001; 72(6): 2008 - 2011.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2001 by The Society of Thoracic Surgeons.