|
|
||||||||
Ann Thorac Surg 2001;71:S116-S120
© 2001 The Society of Thoracic Surgeons
a University of Pittsburgh Medical Center, Pittsburgh, Pennsylvania, USA
b ThermoCardiosystems, Inc, Woburn, Massachusetts, USA
Address reprint requests to Dr Griffith, Division of Cardiothoracic Surgery, University of Pittsburgh Medical Center, C700 UPMC Presbyterian, 200 Lothrop St, Pittsburgh, PA 15213
e-mail: griffithbp{at}msx.upmc.edu
Presented at the Fifth International Conference on Circulatory Support Devices for Severe Cardiac Failure, New York, NY, Sept 1517, 2000.
Abstract
The HeartMate II left ventricular assist device (LVAD) (ThermoCardiosystems, Inc, Woburn, MA) has evolved from 1991 when a partnership was struck between the McGowan Center of the University of Pittsburgh and Nimbus Company. Early iterations were conceptually based on axial-flow mini-pumps (Hemopump) and began with purge bearings. As the project developed, so did the understanding of new bearings, computational fluid design and flow visualization, and speed control algorithms. The acquisition of Nimbus by ThermoCardiosystems, Inc (TCI) sped developments of cannulas, controller, and power/monitor units. The system has been successfully tested in more than 40 calves since 1997 and the first human implant occurred in July 2000. Multicenter safety and feasibility trials are planned for Europe and soon thereafter a trial will be started in the United States to test 6-month survival in end-stage heart failure.
This article has been cited by other articles:
![]() |
L. W. Miller, F. D. Pagani, S. D. Russell, R. John, A. J. Boyle, K. D. Aaronson, J. V. Conte, Y. Naka, D. Mancini, R. M. Delgado, et al. Use of a Continuous-Flow Device in Patients Awaiting Heart Transplantation N. Engl. J. Med., August 30, 2007; 357(9): 885 - 896. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. H. Huber, P. Tozzi, M. Hurni, and L. K. von Segesser No drive line, no seal, no bearing and no wear: magnetics for impeller suspension and flow assessment in a new VAD Interactive CardioVascular and Thoracic Surgery, June 1, 2004; 3(2): 336 - 340. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. L. Kukuy, M. C. Oz, and Y. Naka Long-Term Mechanical Circulatory Support Card. Surg. Adult, January 1, 2003; 2(2003): 1491 - 1506. [Full Text] |
||||
![]() |
Y. Ochiai, P. M. McCarthy, N. G. Smedira, M. K. Banbury, J. L. Navia, J. Feng, A. P. Hsu, M. L. Yeager, T. Buda, K. J. Hoercher, et al. Predictors of Severe Right Ventricular Failure After Implantable Left Ventricular Assist Device Insertion: Analysis of 245 Patients Circulation, September 24, 2002; 106(12_suppl_1): I-198 - I-202. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Westaby, O.H. Frazier, F. Beyersdorf, S. Saito, M. P. Siegenthaler, D. W. Pigott, P. A. Catarino, and R. Jarvik The Jarvik 2000 Heart. Clinical validation of the intraventricular position Eur. J. Cardiothorac. Surg., August 1, 2002; 22(2): 228 - 232. [Abstract] [Full Text] [PDF] |
||||
![]() |
F Duru, R Candinas, M Lachat, M Rahn, G Noll, T.F Luscher, and M Turina Electrical and mechanical support in advanced heart failure. Rationale and feasibility of a combined management strategy Eur. Heart J., July 1, 2002; 23(13): 1005 - 1010. [Full Text] [PDF] |
||||
![]() |
T. A. Snyder, M. J. Watach, K. N. Litwak, and W. R. Wagner Platelet activation, aggregation, and life span in calves implanted with axial flow ventricular assist devices Ann. Thorac. Surg., June 1, 2002; 73(6): 1933 - 1938. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |