ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Takakura, H.
Right arrow Articles by Takeuchi, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Takakura, H.
Right arrow Articles by Takeuchi, S.
Related Collections
Right arrow Valve disease

Ann Thorac Surg 2001;71:609-613
© 2001 The Society of Thoracic Surgeons


Original article: cardiovascular

Hemodynamic evaluation of 19-mm Carpentier-Edwards pericardial bioprosthesis in aortic position

Hiromitsu Takakura, MDa, Tatsuumi Sasaki, MDa, Kazuhiro Hashimoto, MDa, Takashi Hachiya, MDa, Katsuhisa Onoguchi, MDa, Motohiro Oshiumi, MDa, Shigeyuki Takeuchi, MDa

a Department of Cardiovascular Surgery, Saitama Cardiovascular and Respiratory Center, Saitama, Japan

Accepted for publication July 15, 2000.

Address reprint requests to Dr Takakura, 1696 Itai, Konan-machi, Osato-gun, Saitama 360-0105, Japan
e-mail: idabagus{at}yj8.so-net.ne.jp

Background. The aortic Carpentier-Edwards pericardial bioprosthesis offers good long-term clinical outcomes with a low rate of structural deterioration. However, little in vivo hemodynamic data is available for this bioprosthesis.

Methods. To determine the hemodynamic performance of the 19-mm Carpentier-Edwards pericardial valve, both cardiac catheterization and dobutamine stress echocardiography were electively performed in 10 patients. The mean age at the study was 71.6 ± 4.4 years and the mean body surface area was 1.39 ± 0.11 m2. The peak-to-peak gradient, instantaneous peak gradient, mean gradient, and valve orifice area were measured by standard cardiac catheterization. The Doppler-derived gradients and valve orifice area were also measured both at rest and during dobutamine infusion.

Results. The average peak-to-peak gradient, instantaneous peak gradient, mean gradient, and valve orifice area measured by catheterization were 13.0 ± 5.4 mmHg, 28.5 ± 7.7 mmHg, 12.0 ± 4.9 mmHg, and 1.55 ± 0.45 cm2, respectively. The peak and mean Doppler gradients, and valve orifice area by resting echocardiography were 27.7 ± 9.5 mmHg, 12.3 ± 4.8 mmHg, and 1.39 ± 0.26 cm2, respectively. At a dosage of 10 µg/kg/min of dobutamine, the mean Doppler gradient rose mildly to 22.2 ± 4.8 mmHg, while the cardiac output increased from 4.49 ± 0.44 to 6.64 ± 0.87 L/min. The valve orifice area during the 10 µg/kg/min dobutamine infusion (1.55 ± 0.25 cm2) was significantly larger than its value at rest (p < 0.05).

Conclusions. With acceptable hemodynamic performance, use of the aortic 19-mm Carpentier-Edwards pericardial valve is a reliable option for elderly patients with a small annulus.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
T. Takaseya, T. Kawara, S. Tokunaga, M. Kohno, Y. Oishi, and S. Morita
Aortic Valve Replacement With 17-mm St. Jude Medical Prostheses for a Small Aortic Root in Elderly Patients
Ann. Thorac. Surg., June 1, 2007; 83(6): 2050 - 2053.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
I. M. Wagner, W. B. Eichinger, S. Bleiziffer, F. Botzenhardt, I. Gebauer, R. Guenzinger, R. Bauernschmitt, and R. Lange
Influence of completely supra-annular placement of bioprostheses on exercise hemodynamics in patients with a small aortic annulus
J. Thorac. Cardiovasc. Surg., May 1, 2007; 133(5): 1234 - 1241.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Sakamoto, K. Hashimoto, H. Okuyama, H. Takakura, S. Ishii, S. Taguchi, and H. Kagawa
Prevalence and Avoidance of Patient-Prosthesis Mismatch in Aortic Valve Replacement in Small Adults
Ann. Thorac. Surg., April 1, 2006; 81(4): 1305 - 1309.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
F. Botzenhardt, W. B. Eichinger, S. Bleiziffer, R. Guenzinger, I. M. Wagner, R. Bauernschmitt, and R. Lange
Hemodynamic Comparison of Bioprostheses for Complete Supra-Annular Position in Patients With Small Aortic Annulus
J. Am. Coll. Cardiol., June 21, 2005; 45(12): 2054 - 2060.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. Tasca, F. Brunelli, M. Cirillo, A. Amaducci, Z. Mhagna, G. Troise, and E. Quaini
Mass regression in aortic stenosis after valve replacement with small size pericardial bioprosthesis
Ann. Thorac. Surg., October 1, 2003; 76(4): 1107 - 1113.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. Cohen
Reply
Ann. Thorac. Surg., August 1, 2003; 76(2): 657 - 658.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
X. M. Mueller and L. K. von Segesser
A new equine pericardial stentless valve
J. Thorac. Cardiovasc. Surg., June 1, 2003; 125(6): 1405 - 1411.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
N. Vitale, S. C. Clark, A. Ramsden, A. Hasan, C. J. Hilton, and M. P. Holden
Clinical and hemodynamic evaluation of small perimount aortic valves in patients aged 75 years or older
Ann. Thorac. Surg., January 1, 2003; 75(1): 35 - 39.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2001 by The Society of Thoracic Surgeons.