Background. The aim of this study was to evaluate the effects of a short period of ischemia (10 mins) and a prolonged period of ischemia (60 mins) followed by reperfusion on coronary flow changes induced by acetylcholine (ACh), adenosine (ADO), and endothelin (ET).
Methods. The left anterior descending coronary artery in anesthetized pigs was occluded for 10 or 60 minutes followed by 120 minutes reperfusion. Thereafter, the flow changes in the left anterior descending coronary artery were studied after intracoronary infusion of ACh, ADO, and ET.
Results. Short-term ischemia (10 minutes) caused a decrease in vasodilatation, but not the vasoconstriction response to ACh. Prolonged ischemia (60 minutes) impaired ADO induced vasodilatation and aggravated ET evoked vasoconstriction.
Conclusions. The present findings suggest that a short period of ischemia (10 minutes) causes disturbances of the endothelial regulation of coronary vascular tone and that this endothelial regulation is more sensitive, and precedes changes in vascular smooth muscle function after ischemia and reperfusion.
This article has been cited by other articles:
![]() |
V. A. Mannacio, V. De Amicis, L. Di Tommaso, F. Iorio, and C. Vosa Influence of prosthesis-patient mismatch on exercise-induced arrhythmias: A further aspect after aortic valve replacement J. Thorac. Cardiovasc. Surg., September 1, 2009; 138(3): 632 - 638. [Abstract] [Full Text] [PDF] |
||||
![]() |
M.-A. Clavel, J. G. Webb, P. Pibarot, L. Altwegg, E. Dumont, C. Thompson, R. De Larochelliere, D. Doyle, J.-B. Masson, S. Bergeron, et al. Comparison of the Hemodynamic Performance of Percutaneous and Surgical Bioprostheses for the Treatment of Severe Aortic Stenosis J. Am. Coll. Cardiol., May 19, 2009; 53(20): 1883 - 1891. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Bleiziffer, W. B Eichinger, I. Hettich, R. Guenzinger, D. Ruzicka, R. Bauernschmitt, and R. Lange Prediction of valve prosthesis-patient mismatch prior to aortic valve replacement: which is the best method? Heart, May 1, 2007; 93(5): 615 - 620. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. R. Bridges, S. M. O'Brien, J. C. Cleveland, E. B. Savage, J. S. Gammie, F. H. Edwards, E. D. Peterson, and F. L. Grover Association between indices of prosthesis internal orifice size and operative mortality after isolated aortic valve replacement J. Thorac. Cardiovasc. Surg., April 1, 2007; 133(4): 1012 - 1021. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Chatel, C. Mica, D. Blanchard, F. Baud, D. Bruere, A. Maudiere, and P. Peycher Short-term hemodynamic advantages of stentless CryoLife-O'Brien valve over stented bioprostheses for aortic valve replacement Interactive CardioVascular and Thoracic Surgery, October 1, 2006; 5(5): 578 - 580. [Abstract] [Full Text] [PDF] |
||||
![]() |
P Pibarot and J G Dumesnil Prosthesis-patient mismatch: definition, clinical impact, and prevention Heart, August 1, 2006; 92(8): 1022 - 1029. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Kulik, I. G. Burwash, V. Kapila, T. G. Mesana, and M. Ruel Long-Term Outcomes After Valve Replacement for Low-Gradient Aortic Stenosis: Impact of Prosthesis-Patient Mismatch Circulation, July 4, 2006; 114(1_suppl): I-553 - I-558. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Dalmau, J. MariaGonzalez-Santos, J. Lopez-Rodriguez, M. Bueno, and A. Arribas The Carpentier-Edwards Perimount Magna aortic xenograft: a new design with an improved hemodynamic performance Interactive CardioVascular and Thoracic Surgery, June 1, 2006; 5(3): 263 - 267. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. B. A. Van den Brink Evaluation of Prosthetic Heart Valves by Transesophageal Echocardiography: Problems, Pitfalls, and Timing of Echocardiography Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 2006; 10(1): 89 - 100. [Abstract] [PDF] |
||||
![]() |
M. A. Borger, S. M. Carson, J. Ivanov, V. Rao, H. E. Scully, C. M. Feindel, and T. E. David Stentless Aortic Valves are Hemodynamically Superior to Stented Valves During Mid-Term Follow-Up: A Large Retrospective Study Ann. Thorac. Surg., December 1, 2005; 80(6): 2180 - 2185. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Penta de Peppo, J. Zeitani, P. Nardi, G. Iaci, P. Polisca, R. De Paulis, and L. Chiariello Small "Functional" Size after Mechanical Aortic Valve Replacement: No Risk in Young to Middle-Age Patients Ann. Thorac. Surg., June 1, 2005; 79(6): 1915 - 1920. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. G. Fuster, J. A. M. Argudo, O. G. Albarova, F. H. Sos, S. C. Lopez, M. B. Codoner, J. A. B. Minano, and I. R. Albarran Patient-prosthesis mismatch in aortic valve replacement: really tolerable? Eur. J. Cardiothorac. Surg., March 1, 2005; 27(3): 441 - 449. [Abstract] [Full Text] [PDF] |
||||
![]() |
R.-U. Kuehnel, R. Puchner, A. Pohl, M. O. Wendt, M. Hartrumpf, M. Pohl, and J. M. Albes Characteristic resistance curves of aortic valve substitutes facilitate individualized decision for a particular type Eur. J. Cardiothorac. Surg., March 1, 2005; 27(3): 450 - 455. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Amarelli, A. Della Corte, G. Romano, G. Iasevoli, G. Dialetto, L. S. De Santo, M. De Feo, M. Torella, M. Scardone, and M. Cotrufo Left ventricular mass regression after aortic valve replacement with 17-mm St Jude Medical mechanical prostheses in isolated aortic stenosis J. Thorac. Cardiovasc. Surg., March 1, 2005; 129(3): 512 - 517. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Tasca, F. Brunelli, M. Cirillo, M. DallaTomba, Z. Mhagna, G. Troise, and E. Quaini Impact of Valve Prosthesis-Patient Mismatch on Left Ventricular Mass Regression Following Aortic Valve Replacement Ann. Thorac. Surg., February 1, 2005; 79(2): 505 - 510. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. G. Dumesnil and P. Pibarot Prosthesis size and prosthesis-patient size are unrelated to prosthesis-patient mismatch J. Thorac. Cardiovasc. Surg., June 1, 2004; 127(6): 1852 - 1852. [Full Text] [PDF] |
||||
![]() |
E. H. Blackstone, A. M. Gillinov, and D. M. Cosgrove Reply to the Editor J. Thorac. Cardiovasc. Surg., June 1, 2004; 127(6): 1852 - 1854. [Full Text] [PDF] |
||||
![]() |
M. Ruel, F. D. Rubens, R. G. Masters, A. L. Pipe, P. Bedard, P. J. Hendry, B. K. Lam, I. G. Burwash, W. G. Goldstein, M. P. Brais, et al. Late incidence and predictors of persistent or recurrent heart failure in patients with aortic prosthetic valves J. Thorac. Cardiovasc. Surg., January 1, 2004; 127(1): 149 - 159. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. H. Blackstone, D. M. Cosgrove, W.R. E. Jamieson, N. J. Birkmeyer, J. H. Lemmer Jr, D. C. Miller, E. G. Butchart, G. Rizzoli, M. Yacoub, and A. Chai Prosthesis size and long-term survival after aortic valve replacement J. Thorac. Cardiovasc. Surg., September 1, 2003; 126(3): 783 - 793. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. M. Gillinov, E. H. Blackstone, and L. L. Rodriguez Prosthesis-patient size: measurement and clinical implications J. Thorac. Cardiovasc. Surg., August 1, 2003; 126(2): 313 - 316. [Full Text] [PDF] |
||||
![]() |
S. Bevilacqua, J. Gianetti, A. Ripoli, U. Paradossi, A. Giuseppe Cerillo, M. Glauber, M. L. Sacha Matteucci, M. Senni, A. Gamba, E. Quaini, et al. Aortic valve disease with severe ventricular dysfunction: stentless valve for better recovery Ann. Thorac. Surg., December 1, 2002; 74(6): 2016 - 2021. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. M. Strotmann, J. Bauersachs, D. Fraccarollo, M. Kirchengast, P. A. Schnabel, J. Sykora, G. Ertl, and W. Voelker Trauma induced by nontraumatic coronary devices and its impact on vascular reactivity and morphology Am J Physiol Heart Circ Physiol, December 1, 2002; 283(6): H2356 - H2362. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Lockowandt and A. Franco-Cereceda Is there a role for endothelin-blockade early after coronary artery bypass grafting? Ann. Thorac. Surg., September 1, 2002; 74(3): 727 - 732. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. J. Castro, J. M. Arcidi Jr, A. L. Fisher, and V. A. Gaudiani Routine enlargement of the small aortic root: a preventive strategy to minimize mismatch Ann. Thorac. Surg., July 1, 2002; 74(1): 31 - 36. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. J Flood, L. Willems, and J. P Headrick Coronary function and adenosine receptor-mediated responses in ischemic-reperfused mouse heart Cardiovasc Res, July 1, 2002; 55(1): 161 - 170. [Abstract] [Full Text] [PDF] |
||||
![]() |
U. Lockowandt and A. Franco-Cereceda Off-pump coronary bypass surgery causes less immediate postoperative coronary endothelial dysfunction compared to on-pump coronary bypass surgery Eur. J. Cardiothorac. Surg., December 1, 2001; 20(6): 1147 - 1151. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |