ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by von Oppell, U. O.
Right arrow Articles by Mohr, F. W.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by von Oppell, U. O.
Right arrow Articles by Mohr, F. W.

Ann Thorac Surg 2000;70:2166-2168
© 2000 The Society of Thoracic Surgeons


How to do it

Chordal replacement for both minimally invasive and conventional mitral valve surgery using premeasured Gore-Tex loops

Ulrich Otto von Oppell, PhD, FCS (SA)b, Friedrich W. Mohr, MD, PhDa

a Herzzentrum, University of Leipzig, Leipzig, Germany
b Department of Cardiothoracic Surgery, University of Cape Town, Cape Town, South Africa

Accepted for publication May 25, 2000.

Address reprint requests to Dr von Oppell, Department of Cardiothoracic Surgery, School of Medicine, University of Cape Town, Cape Town, 7925, South Africa
e-mail: uvonopp{at}thoracic.cts.uct.ac.za

Part of the complexity of mitral valve chordal replacement with expanded polytetrafluoroethylene (ePTFE) sutures is determining the correct replacement chordal length and knotting the ePTFE suture without sliding the knot. We describe a technique of measuring the required chordal length and making a "premeasured" Gore-Tex chordal loop that abolishes problems of inadvertently altering chordal length during fixation. This improves the reproducibility of chordal replacement surgery, and can be used both via conventional and minimally invasive approaches.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
A. M. Gillinov, E. H. Blackstone, A. Alaulaqi, J. F. Sabik III, T. Mihaljevic, L. G. Svensson, P. L. Houghtaling, A. Salemi, D. R. Johnston, and B. W. Lytle
Outcomes After Repair of the Anterior Mitral Leaflet for Degenerative Disease
Ann. Thorac. Surg., September 1, 2008; 86(3): 708 - 717.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
T. Kuntze, M. A. Borger, V. Falk, J. Seeburger, E. Girdauskas, N. Doll, T. Walther, and F. W. Mohr
Early and mid-term results of mitral valve repair using premeasured Gore-Tex loops ('loop technique')
Eur. J. Cardiothorac. Surg., April 1, 2008; 33(4): 566 - 572.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. W.A. Chu, K. A. Gersch, E. Rodriguez, L. W. Nifong, and W. R. Chitwood Jr
Robotic "Haircut" Mitral Valve Repair: Posterior Leaflet-Plasty
Ann. Thorac. Surg., April 1, 2008; 85(4): 1460 - 1462.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. M. Smith and H. Stein
Endoscopic placement of multiple artificial chordae with robotic assistance and nitinol clip fixation
J. Thorac. Cardiovasc. Surg., March 1, 2008; 135(3): 610 - 614.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
E. Rodriguez, L. W. Nifong, M. W.A. Chu, W. Wood, P. W. Vos, and W. R. Chitwood
Robotic Mitral Valve Repair for Anterior Leaflet and Bileaflet Prolapse
Ann. Thorac. Surg., February 1, 2008; 85(2): 438 - 444.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. M. Gillinov and M. K. Banbury
Pre-Measured Artificial Chordae for Mitral Valve Repair
Ann. Thorac. Surg., December 1, 2007; 84(6): 2127 - 2129.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
H. Morimoto, K. Tsuchiya, M. Nakajima, Y. Mitsumori, and K. Kato
Chordal Replacement with Temporary Alfieri Stitch for Anterior Leaflet Prolapse
Asian Cardiovasc Thorac Ann, December 1, 2007; 15(6): 531 - 533.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. H. Mandegar, M. A. Yousefnia, and F. Roshanali
Preoperative Determination of Artificial Chordae Length
Ann. Thorac. Surg., August 1, 2007; 84(2): 680 - 682.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. Maselli, R. De Paulis, L. Weltert, A. Salica, R. Scaffa, A. Bellisario, and A. Mingiano
A new method for artificial chordae length "tuning" in mitral valve repair: Preliminary experience
J. Thorac. Cardiovasc. Surg., August 1, 2007; 134(2): 454 - 459.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
K. Fattouch, G. Bianco, F. Sbraga, R. Sampognaro, and G. Ruvolo
Simple, Safe and Easy Technique to Ensure the Correct Length of Artificial Chordae in Mitral Valve Repair
Ann. Thorac. Surg., May 1, 2007; 83(5): 1902 - 1903.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
S. Taguchi, K. Hashimoto, Y. Sakamoto, H. Okuyama, and S. Ishii
A case of mitral valve plasty for Libman-Sacks endocarditis mimicking a cardiac tumor
J. Thorac. Cardiovasc. Surg., December 1, 2006; 132(6): 1465 - 1467.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. Tam, P. Joshi, and I. E. Konstantinov
A simple method of preparing artificial chordae for mitral valve repair
J. Thorac. Cardiovasc. Surg., December 1, 2006; 132(6): 1486 - 1487.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. M. Calafiore, M. Di Mauro, A. L. Iaco, V. Mazzei, G. Teodori, S. Gallina, L. Weltert, M. Samoun, and G. Di Giammarco
Overreduction of the Posterior Annulus in Surgical Treatment of Degenerative Mitral Regurgitation
Ann. Thorac. Surg., April 1, 2006; 81(4): 1310 - 1316.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. M. Calafiore
Choice of Artificial Chordae Length According to Echocardiographic Criteria
Ann. Thorac. Surg., January 1, 2006; 81(1): 375 - 377.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
E. Lapenna, L. Torracca, M. De Bonis, G. La Canna, G. Crescenzi, and O. Alfieri
Minimally Invasive Mitral Valve Repair in the Context of Barlow's Disease
Ann. Thorac. Surg., May 1, 2005; 79(5): 1496 - 1499.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Matsui, Y. Fukada, Y. Naito, S. Sasaki, and K. Yasuda
A New Device for Ensuring the Correct Length of Artificial Chordae in Mitral Valvuloplasty
Ann. Thorac. Surg., March 1, 2005; 79(3): 1064 - 1065.
[Abstract] [Full Text] [PDF]


Home page
MMCTSHome page
A. M. Gillinov
Chordal transfer for repair of anterior leaflet prolapse
MMCTS, January 18, 2005; 2005(0118): 901.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. A.I. Sarsam
Simplified technique for determining the length of artificial chordae in mitral valve repair
Ann. Thorac. Surg., May 1, 2002; 73(5): 1659 - 1660.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2000 by The Society of Thoracic Surgeons.