ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Eric Berreklouw
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Tavilla, G.
Right arrow Articles by Berreklouw, E.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Tavilla, G.
Right arrow Articles by Berreklouw, E.

Ann Thorac Surg 2000;70:2040-2044
© 2000 The Society of Thoracic Surgeons


Original article: cardiovascular

Noninvasive assessment of coronary flow reserve in the right gastroepiploic artery graft

Giuseppe Tavilla, MDa, Nico H.J. Pijls, MD, PhDc, Kathinka H. Peels, MDc, Eric Berreklouw, MD, PhDb

a Department of Cardiothoracic Surgery, Leiden University Medical Center, Leiden, The Netherlands
b Department of Cardiothoracic Surgery, Catharina Hospital, Eidenhoven, The Netherlands
c Department of Cardiology, Catharina Hospital, Eindhoven, The Netherlands

Accepted for publication May 25, 2000.

Address reprint requests to Dr Tavilla, Department of Cardiothoracic Surgery, Leiden University Medical Center, K6-S, PO Box 9600, 2300 RC Leiden, The Netherlands
e-mail: gtavilla{at}lumc.nl

Background. To investigate the functional capacity of the right gastroepiploic artery graft (GEA) and its ability to adapt to provide adequate flow at peak myocardial demand, we investigated the feasibility of determining coronary flow reserve (CFR) provided by this vessel using transabdominal color Doppler echocardiography and the correlation between this noninvasive determination of flow reserve and nuclear stress scintigraphy.

Methods. In 40 selected patients, who underwent complete arterial myocardial revascularization using the GEA and the internal thoracic arteries (ITAs), CFR of the GEA was measured at maximum coronary hyperemia induced by intravenous adenosine infusion, 7 months (range 3 to 20) after surgery. In the same period, in 31 of this group of patients, exercise thallium scintigraphy was performed.

Results. We succeeded in measuring CFR in 37 of 40 patients with values ranging from 1.1 to 3.6 with an average of 2.1 ± 0.7. During adenosine infusion, mean velocity in the GEA significantly increased from 48 ± 20 to 89 ± 41 cm/sec (p < 0.001), mean arterial blood pressure significantly decreased from 96 ± 11 to 87 ± 11 mm Hg (p < 0.001), and heart rate significantly increased from 74 ± 11 to 87 ± 15 beats/min (p < 0.001). In 8 of these 37 patients, the nuclear exercise test was positive (compatible with reversible ischemia in the distribution area of the GEA). Average CFR in these 8 patients with positive nuclear stress test was 1.46 ± 0.28 versus 2.27 ± 0.70 in those patients with a negative test (p < 0.001).

Conclusions. Noninvasive determination of CFR of GEAs is feasible, using transabdominal Doppler echocardiography. The present study shows that coronary vasodilator reserve and autoregulation is maintained in myocardium supplied by the GEA and that the CFR has a significant correlation with the results of noninvasive nuclear exercise testing. Therefore, noninvasive determination of CFR by transabdominal Doppler echocardiography might be a valuable contribution to functional assessment of GEAs.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
T. Shimizu, H. Suesada, M. Cho, S. Ito, K. Ikeda, and S. Ishimaru
Flow Capacity of Gastroepiploic Artery Versus Vein Grafts for Intermediate Coronary Artery Stenosis
Ann. Thorac. Surg., July 1, 2005; 80(1): 124 - 130.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
F. Formica, O. Ferro, P. Greco, A. Martino, D. Gastaldi, and G. Paolini
Long-term follow-up of total arterial myocardial revascularization using exclusively pedicle bilateral internal thoracic artery and right gastroepiploic artery
Eur. J. Cardiothorac. Surg., December 1, 2004; 26(6): 1141 - 1148.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. Tavilla, A. P. Kappetein, J. Braun, J. Gopie, A. T. J. Tjien, and R. A. E. Dion
Long-term follow-up of coronary artery bypass grafting in three-vessel disease using exclusively pedicled bilateral internal thoracic and right gastroepiploic arteries
Ann. Thorac. Surg., March 1, 2004; 77(3): 794 - 799.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS