Ann Thorac Surg 2000;70:1587-1593
© 2000 The Society of Thoracic Surgeons
a Department of Thoracic and Cardiovascular Surgery, Ny Rikshospitalet, Oslo, Norway
b Department of Cardiology, Rikshospitalet, Oslo, Norway
Address reprint requests to Dr Arafa, Department of Thoracic and Cardiovascular Surgery, Rikshospitalet, N-0027 Oslo, Norway
e-mail: arafa{at}doctor.com
Background. Right ventricular failure from elevated pulmonary vascular resistance in the recipient is a main cause of early mortality after heart transplantation. When pharmacologic treatment is insufficient, mechanical circulatory assistance has been used to support the failing right ventricle. Considering right and left ventricular interdependence, we investigated whether intraaortic balloon counterpulsation (IABP) might also alleviate predominantly right ventricular dysfunction after heart transplantation.
Methods. Among 278 cardiac recipients, 12 adult patients underwent mechanical circulatory support for cardiac allograft dysfunction. Five patients were treated with percutaneous IABP for early postoperative low cardiac output syndrome characterized by predominantly right ventricular failure. Clinical data and hemodynamic variables were recorded before and during IABP treatment.
Results. Cardiac index (CI) and mean arterial pressure (MAP) increased (CI 1.7 ± 0.1 to 2.5 ± 0.2, MAP 53 ± 12 to 71 ± 7, p < 0.05) within 1 hour after IABP, whereas central venous pressure (CVP) and pulmonary artery wedge pressure (PAWP) decreased (CVP 21.6 ± 1.7 to 13.8 ± 3.1, p < .05; PAWP 14.8 ± 4.9 to 12.4 ± 3.7, nonsignificant). Within the next 12 hours, CI and mixed venous oxygen saturation increased (p < 0.05) and pulmonary artery pressure decreased (p < 0.05). All 5 patients were weaned successfully and 4 are long-term survivors with adequate cardiac performance at 1 year follow-up.
Conclusions. Intraaortic balloon pumping is a minimally invasive circulatory assist device with proved efficiency in low cardiac output syndromes. This report shows that low output syndrome caused by predominantly right ventricular allograft failure may be an additional indication for IABP.
This article has been cited by other articles:
![]() |
O. Gjesdal, E. Gude, S. Arora, T. Leivestad, A. K. Andreassen, L. Gullestad, L. Aaberge, H. Brunvand, T. Edvardsen, O. R. Geiran, et al. Intra-aortic balloon counterpulsation as a bridge to heart transplantation does not impair long-term survival Eur J Heart Fail, July 1, 2009; 11(7): 709 - 714. [Abstract] [Full Text] [PDF] |
||||
![]() |
L. U. Nwakanma, A. S. Shah, J. V. Conte, and W. A. Baumgartner Heart Transplantation Card. Surg. Adult, January 1, 2008; 3(2008): 1539 - 1578. [Full Text] |
||||
![]() |
S. Taghavi, A. Zuckermann, J. Ankersmit, G. Wieselthaler, A. Rajek, G. Laufer, E. Wolner, and M. Grimm Extracorporeal Membrane Oxygenation is Superior to Right Ventricular Assist Device for Acute Right Ventricular Failure After Heart Transplantation Ann. Thorac. Surg., November 1, 2004; 78(5): 1644 - 1649. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Tozzi, A.F. Corno, L.V. Lapanashvili, and L.K. von Segesser Muscular counterpulsation: preliminary results of a non-invasive alternative to intra-aortic balloon pump Eur. J. Cardiothorac. Surg., October 1, 2004; 26(4): 726 - 729. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Nordhaug, T. Steensrud, S. Muller, K. V. Husnes, and T. Myrmel Intraaortic Balloon Pumping Improves Hemodynamics and Right Ventricular Efficiency in Acute Ischemic Right Ventricular Failure Ann. Thorac. Surg., October 1, 2004; 78(4): 1426 - 1432. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. S. Poston and B. P. Griffith Heart Transplantation J Intensive Care Med, January 1, 2004; 19(1): 3 - 12. [Abstract] [PDF] |
||||
![]() |
A. W. Khir, S. Price, M. Y. Henein, K. H. Parker, and J. R. Pepper Intra-aortic balloon pumping: effects on left ventricular diastolic function Eur. J. Cardiothorac. Surg., August 1, 2003; 24(2): 277 - 282. [Abstract] [Full Text] [PDF] |
||||
![]() |
K McNeil, J Dunning, and N W Morrell The pulmonary physician in critical care * 13: The pulmonary circulation and right ventricular failure in the ITU Thorax, February 1, 2003; 58(2): 157 - 162. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J.F. Baskett, W. A. Ghali, A. Maitland, and G. M. Hirsch The intraaortic balloon pump in cardiac surgery Ann. Thorac. Surg., October 1, 2002; 74(4): 1276 - 1287. [Abstract] [Full Text] [PDF] |
||||