ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Jan L. Svennevig
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Arafa, O. E.
Right arrow Articles by Svennevig, J. L.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Arafa, O. E.
Right arrow Articles by Svennevig, J. L.

Ann Thorac Surg 2000;70:1587-1593
© 2000 The Society of Thoracic Surgeons


Original articles: cardiovascular

Intraaortic balloon pumping for predominantly right ventricular failure after heart transplantation

Osama E. Arafa, MDa, Odd R. Geiran, MD, PhDa, Kai Andersen, MD, PhDb, Erik Fosse, MD, PhDa, Svein Simonsen, MD, PhDb, Jan L. Svennevig, MD, PhDa

a Department of Thoracic and Cardiovascular Surgery, Ny Rikshospitalet, Oslo, Norway
b Department of Cardiology, Rikshospitalet, Oslo, Norway

Address reprint requests to Dr Arafa, Department of Thoracic and Cardiovascular Surgery, Rikshospitalet, N-0027 Oslo, Norway
e-mail: arafa{at}doctor.com

Background. Right ventricular failure from elevated pulmonary vascular resistance in the recipient is a main cause of early mortality after heart transplantation. When pharmacologic treatment is insufficient, mechanical circulatory assistance has been used to support the failing right ventricle. Considering right and left ventricular interdependence, we investigated whether intraaortic balloon counterpulsation (IABP) might also alleviate predominantly right ventricular dysfunction after heart transplantation.

Methods. Among 278 cardiac recipients, 12 adult patients underwent mechanical circulatory support for cardiac allograft dysfunction. Five patients were treated with percutaneous IABP for early postoperative low cardiac output syndrome characterized by predominantly right ventricular failure. Clinical data and hemodynamic variables were recorded before and during IABP treatment.

Results. Cardiac index (CI) and mean arterial pressure (MAP) increased (CI 1.7 ± 0.1 to 2.5 ± 0.2, MAP 53 ± 12 to 71 ± 7, p < 0.05) within 1 hour after IABP, whereas central venous pressure (CVP) and pulmonary artery wedge pressure (PAWP) decreased (CVP 21.6 ± 1.7 to 13.8 ± 3.1, p < .05; PAWP 14.8 ± 4.9 to 12.4 ± 3.7, nonsignificant). Within the next 12 hours, CI and mixed venous oxygen saturation increased (p < 0.05) and pulmonary artery pressure decreased (p < 0.05). All 5 patients were weaned successfully and 4 are long-term survivors with adequate cardiac performance at 1 year follow-up.

Conclusions. Intraaortic balloon pumping is a minimally invasive circulatory assist device with proved efficiency in low cardiac output syndromes. This report shows that low output syndrome caused by predominantly right ventricular allograft failure may be an additional indication for IABP.




This article has been cited by other articles:


Home page
Card Surg AdultHome page
L. U. Nwakanma, A. S. Shah, J. V. Conte, and W. A. Baumgartner
Heart Transplantation
Card. Surg. Adult, January 1, 2008; 3(2008): 1539 - 1578.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
S. Taghavi, A. Zuckermann, J. Ankersmit, G. Wieselthaler, A. Rajek, G. Laufer, E. Wolner, and M. Grimm
Extracorporeal Membrane Oxygenation is Superior to Right Ventricular Assist Device for Acute Right Ventricular Failure After Heart Transplantation
Ann. Thorac. Surg., November 1, 2004; 78(5): 1644 - 1649.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
P. Tozzi, A.F. Corno, L.V. Lapanashvili, and L.K. von Segesser
Muscular counterpulsation: preliminary results of a non-invasive alternative to intra-aortic balloon pump
Eur. J. Cardiothorac. Surg., October 1, 2004; 26(4): 726 - 729.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. Nordhaug, T. Steensrud, S. Muller, K. V. Husnes, and T. Myrmel
Intraaortic Balloon Pumping Improves Hemodynamics and Right Ventricular Efficiency in Acute Ischemic Right Ventricular Failure
Ann. Thorac. Surg., October 1, 2004; 78(4): 1426 - 1432.
[Abstract] [Full Text] [PDF]


Home page
J Intensive Care MedHome page
R. S. Poston and B. P. Griffith
Heart Transplantation
J Intensive Care Med, January 1, 2004; 19(1): 3 - 12.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. W. Khir, S. Price, M. Y. Henein, K. H. Parker, and J. R. Pepper
Intra-aortic balloon pumping: effects on left ventricular diastolic function
Eur. J. Cardiothorac. Surg., August 1, 2003; 24(2): 277 - 282.
[Abstract] [Full Text] [PDF]


Home page
ThoraxHome page
K McNeil, J Dunning, and N W Morrell
The pulmonary physician in critical care * 13: The pulmonary circulation and right ventricular failure in the ITU
Thorax, February 1, 2003; 58(2): 157 - 162.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. J.F. Baskett, W. A. Ghali, A. Maitland, and G. M. Hirsch
The intraaortic balloon pump in cardiac surgery
Ann. Thorac. Surg., October 1, 2002; 74(4): 1276 - 1287.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2000 by The Society of Thoracic Surgeons.