Ann Thorac Surg 2000;70:1577-1579
© 2000 The Society of Thoracic Surgeons
a Department of Cardiothoracic Surgery, General Hospital Klagenfurt, Klagenfurt, Austria
b Department of Anesthesiology, General Hospital Klagenfurt, Klagenfurt, Austria
c Institute for Laboratory Medicine, General Hospital Klagenfurt, Klagenfurt, Austria
Address reprint requests to Dr Wandschneider, Department of Cardiothoracic Surgery, General Hospital Klagenfurt, St. Veiter Strasse 47, A-9020 Klagenfurt, Austria
e-mail: wwand{at}netway.at
Background. Cardiac operations using extracorporeal circulation bear a risk of cerebral complications. The aim of our study was to investigate if off-pump operations without heart-lung machines can reduce cerebral injury.
Methods. S100, a protein specific for cerebral tissue, was used as a marker for cerebral impairment in 108 randomized patients undergoing coronary bypass operation: 67 patients (group A) were operated on with extracorporeal circulation and cardioplegic cardiac arrest, and 41 patients (group B) underwent off-pump beating heart revascularization. Both groups were similar regarding age, sex, ejection fraction, and number of anastomoses. S100 levels were measured from induction of anesthesia until 24 hours after the operation.
Results. Data collection was 100% complete. There was no in-hospital death. Nonfatal myocardial infarctions occurred in 2 patients in group A, and 1 patient in group B required resternotomy for bleeding. There was no neurologic deficit in either group. S100 levels increased only slightly in the off-pump patients (group B), whereas in group A there was a sharp rise in S100 concentration during extracorporeal circulation, only returning to baseline 6 hours after the end of the operation. Peak S100 levels were four times higher in group A than in group B (2.1 µg/L versus 0.5 µg/L; p < 001).
Conclusions. The results of our study suggest that perioperative cerebral impairment is reduced in cardiac operations without the use of extracorporeal circulation. Further large-scale studies are needed to show whether this result is reflected by fewer neurologic deficits.
This article has been cited by other articles:
![]() |
C. H. Moller, L. Penninga, J. Wetterslev, D. A. Steinbruchel, and C. Gluud Clinical outcomes in randomized trials of off- vs. on-pump coronary artery bypass surgery: systematic review with meta-analyses and trial sequential analyses Eur. Heart J., November 1, 2008; 29(21): 2601 - 2616. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G Raja and G. D Dreyfus Current Status of Off-pump Coronary Artery Bypass Surgery Asian Cardiovasc Thorac Ann, April 1, 2008; 16(2): 164 - 178. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. Dewey and M. J. Mack Myocardial Revascularization without Cardiopulmonary Bypass Card. Surg. Adult, January 1, 2008; 3(2008): 633 - 654. [Full Text] |
||||
![]() |
A. Sedrakyan, A. W. Wu, A. Parashar, E. B. Bass, and T. Treasure Off-Pump Surgery Is Associated With Reduced Occurrence of Stroke and Other Morbidity as Compared With Traditional Coronary Artery Bypass Grafting: A Meta-Analysis of Systematically Reviewed Trials * Supplemental Appendix I Stroke, November 1, 2006; 37(11): 2759 - 2769. [Full Text] [PDF] |
||||
![]() |
D. N. Wijeysundera, W. S. Beattie, G. Djaiani, V. Rao, M. A. Borger, K. Karkouti, and R. J. Cusimano Off-Pump Coronary Artery Surgery for Reducing Mortality and Morbidity: Meta-Analysis of Randomized and Observational Studies J. Am. Coll. Cardiol., September 6, 2005; 46(5): 872 - 882. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. Diephuis, K. G. M. Moons, A. N. Nierich, M. Bruens, D. van Dijk, and C. J. Kalkman Jugular bulb desaturation during coronary artery surgery: a comparison of off-pump and on-pump procedures Br. J. Anaesth., June 1, 2005; 94(6): 715 - 720. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Bainbridge, J. Martin, and D. Cheng Off Pump Coronary Artery Bypass Graft Surgery Versus Conventional Coronary Artery Bypass Graft Surgery: A Systematic Review of the Literature Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 2005; 9(1): 105 - 111. [Abstract] [PDF] |
||||
![]() |
G. J Murphy, R. Ascione, and G. D Angelini Coronary artery bypass grafting on the beating heart: surgical revascularization for the next decade? Eur. Heart J., December 1, 2004; 25(23): 2077 - 2085. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. J.M.G. van der Heijden, H. M. Nathoe, E. W.L. Jansen, and D. E. Grobbee Meta-analysis on the effect of off-pump coronary bypass surgery Eur. J. Cardiothorac. Surg., July 1, 2004; 26(1): 81 - 84. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. T. Reston, S. J. Tregear, and C. M. Turkelson Meta-analysis of short-term and mid-term outcomes following off-pump coronary artery bypass grafting Ann. Thorac. Surg., November 1, 2003; 76(5): 1510 - 1515. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Parolari, F. Alamanni, A. Cannata, M. Naliato, L. Bonati, P. Rubini, F. Veglia, E. Tremoli, and P. Biglioli Off-pump versus on-pump coronary artery bypass: meta-analysis of currently available randomized trials Ann. Thorac. Surg., July 1, 2003; 76(1): 37 - 40. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Mazzone, J. Gianetti, E. Picano, S. Bevilacqua, G. Zucchelli, A. Biagini, and M. Glauber Correlation between inflammatory response and markers of neuronal damage in coronary revascularization with and without cardiopulmonary bypass Perfusion, January 1, 2003; 18(1): 3 - 8. [Abstract] [PDF] |
||||
![]() |
Y. Fromes, D. Gaillard, O. Ponzio, M. Chauffert, M.-F. Gerhardt, P. Deleuze, and O. M. Bical Reduction of the inflammatory response following coronary bypass grafting with total minimal extracorporeal circulation Eur. J. Cardiothorac. Surg., October 1, 2002; 22(4): 527 - 533. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. F. Sabik, A. M. Gillinov, E. H. Blackstone, C. Vacha, P. L. Houghtaling, J. Navia, N. G. Smedira, P. M. McCarthy, D. M. Cosgrove, and B. W. Lytle Does off-pump coronary surgery reduce morbidity and mortality? J. Thorac. Cardiovasc. Surg., October 1, 2002; 124(4): 698 - 707. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Menasche The systemic factor: the comparative roles of cardiopulmonary bypass and off-pump surgery in the genesis of patient injury during and following cardiac surgery Ann. Thorac. Surg., December 1, 2001; 72(6): S2260 - 2265. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Asimakopoulos Systemic inflammation and cardiac surgery: an update Perfusion, September 1, 2001; 16(5): 353 - 360. [Abstract] [PDF] |
||||
![]() |
N. E. Khan, A. C. De Souza, and J. R. Pepper S100 protein: its use as a marker of cerebral damage in cardiac operations Ann. Thorac. Surg., August 1, 2001; 72(2): 666 - 667. [Full Text] [PDF] |
||||
![]() |
D. Whitaker S100 release as an indicator of cerebral damage Ann. Thorac. Surg., June 1, 2001; 71(6): 2085 - 2085. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |