ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Kazumasa Orihashi
Yuichiro Matsuura
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sueda, T.
Right arrow Articles by Matsuura, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sueda, T.
Right arrow Articles by Matsuura, Y.

Ann Thorac Surg 2000;70:1251-1254
© 2000 The Society of Thoracic Surgeons


Original articles: cardiovascular

Endovascular stent-grafting through the aortic arch: an alternative approach for distal arch aortic aneurysm

Taijiro Sueda, MDa, Masanobu Watari, MDa, Kenji Okada, MDa, Kazumasa Orihashi, MDa, Yuichiro Matsuura, MDa

a First Department of Surgery, Hiroshima University School of Medicine, Hiroshima, Japan

Address reprint requests to Dr Sueda, First Department of Surgery, Hiroshima University School of Medicine, 1-2-3 Kasumi, Minami-ku, Hiroshima, 734-8551, Japan
e-mail: sueda{at}mcai.med.hiroshima-u.ac.jp

Background. Endovascular stent-grafting is an innovative procedure; we have developed a novel approach to treat distal arch aortic aneurysm through a small incision in the aortic arch.

Methods. Eight patients with thoracic aortic aneurysms were treated with an endovascular stent-graft that was introduced into the thoracic aorta through a small incision in the aortic arch. Of these patients, 7 had distal arch aortic aneurysms, and 1 had chronic aortic dissection of Stanford type B. Four of these patients had received concomitant coronary artery bypass grafting, and 1 patient had undergone tricuspid valvular annuloplasty. The stent-graft was introduced into the distal arch aorta and descending aorta through a small incision in the aortic arch, under selective cerebral perfusion and hypothermic circulatory arrest.

Results. The selective cerebral perfusion time ranged from 52 to 86 minutes (mean, 68 minutes) and the operating time from 289 to 422 minutes (mean, 318 minutes). There was no endoluminal leakage into the aneurysm. Seven patients survived and were discharged, but 1 patient suffered a cerebral infarction and died during the follow-up period.

Conclusions. Placing an endovascular stent-graft through the aortic arch is an acceptable alternative treatment for distal arch aortic aneurysms.




This article has been cited by other articles:


Home page
ICVTSHome page
A. H. M. Bashar, T. Kazui, K. Suzuki, H. Terada, K. Yamashita, and N. Washiyama
Open stent-grafting: aborted procedure in a patient with mega aorta syndrome
Interactive CardioVascular and Thoracic Surgery, August 1, 2006; 5(4): 456 - 458.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. Flores, T. Kunihara, N. Shiiya, K. Yoshimoto, K. Matsuzaki, and K. Yasuda
Extensive deployment of the stented elephant trunk is associated with an increased risk of spinal cord injury
J. Thorac. Cardiovasc. Surg., February 1, 2006; 131(2): 336 - 342.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
K. Orihashi, T. Sueda, K. Okada, and K. Imai
Malposition of selective cerebral perfusion catheter is not a rare event
Eur. J. Cardiothorac. Surg., April 1, 2005; 27(4): 644 - 648.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
T. Sueda, K. Orihashi, K. Okada, Y. Sugawara, K. Imai, and M. Hamamoto
Successful shrinkage of distal arch and proximal descending aortic aneurysm after transaortic endovascular stent-grafting
Eur. J. Cardiothorac. Surg., May 1, 2004; 25(5): 716 - 721.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
K. Higuchi, K. Koseni, M. Hisaki, Y. Kotsuka, and S. Takamoto
Surgical Repair of a Distal Arch Aneurysm with a Stent-graft
Asian Cardiovasc Thorac Ann, December 1, 2003; 11(4): 332 - 336.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Sueda, K. Orihashi, K. Okada, Y. Sugawara, K. Imai, and K. Kochi
Fate of aneurysms of the distal arch and proximal descending thoracic aorta after transaortic endovascular Stent-Grafting
Ann. Thorac. Surg., July 1, 2003; 76(1): 84 - 89.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
T. Mizuno, M. Toyama, N. Tabuchi, H. Wu, and M. Sunamori
Stented elephant trunk procedure combined with ascending aorta and arch replacement for acute type A aortic dissection
Eur. J. Cardiothorac. Surg., October 1, 2002; 22(4): 504 - 509.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
N. A.G. Stolf
On the originality of the technique described by Sueda and coworkers
Ann. Thorac. Surg., February 1, 2002; 73(2): 694 - 694.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Watari, T. Sueda, O. Ishii, K. Imai, S. Hidenori, H. Sakai, H. Wada, K. Okada, and K. Orihashi
Shrinkage of excluded aneurysmal spaces: The excellent results of endovascular stent grafting through the aortic arch for distal arch aneurysm
J. Thorac. Cardiovasc. Surg., October 1, 2001; 122(4): 829 - 832.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2000 by The Society of Thoracic Surgeons.