Ann Thorac Surg 2000;70:1154-1159
© 2000 The Society of Thoracic Surgeons
a Division of Cardiothoracic Surgery, University of California, Davis, Sacramento, California, USA
b Northern California PET Imaging Center, Sacramento, California, USA
Address reprint requests to Dr Roberts, Division of Cardiothoracic Surgery, University of California, Davis, 2221 Stockton Blvd, 2nd floor, Sacramento, CA 95817
e-mail: peter.roberts{at}ucdmc.ucdavis.edu
Presented at the Thirty-sixth Annual Meeting of The Society of Thoracic Surgeons, Fort Lauderdale, FL, Jan 31Feb 2, 2000.
Background. Positron emission tomography imaging is gaining popularity as a noninvasive staging tool in non-small cell lung cancer. Nonmalignant processes can also affect radio-tracer uptake. This study seeks to identify factors associated with false-positive staging of mediastinal metastases.
Methods. A retrospective review was performed of 100 patients with early stage non-small cell lung cancer referred for positron emission tomography scan evaluation. All had pathologic confirmation of their disease. Positron emission tomography scans, radiology records, operative reports, and pathology results were reviewed. Patients with positron emission tomography scans interpreted as positive for mediastinal involvement and negative pathology at operation were selected.
Results. Seven patients were found to have a false-positive positron emission tomography evaluation for mediastinal metastases. All but 1 patient had a concurrent inflammatory process or an anatomic factor associated with the false positive. The sensitivity and specificity in detecting involved mediastinal nodes was 87.5% and 90.7%, respectively. The negative predictive value was 95.8%.
Conclusions. Although positron emission tomography has been established as an accurate modality to stage non-small cell lung cancer, false-positive evaluation of mediastinal metastases can occur in the setting of concurrent inflammatory lung diseases or for centrally located tumors. Pathologic evaluation of mediastinal disease should be pursued whenever suggested by a positive positron emission tomography scan especially in the face of those factors described.
This article has been cited by other articles:
![]() |
M. G. Benninghoff, W. U. Todd, and R. Bascom Incidental Pleural-Based Pulmonary Lymphangioma J Am Osteopath Assoc, September 1, 2008; 108(9): 525 - 528. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Nomori, T. Mori, K. Ikeda, K. Kawanaka, S. Shiraishi, K. Katahira, and Y. Yamashita Diffusion-weighted magnetic resonance imaging can be used in place of positron emission tomography for N staging of non-small cell lung cancer with fewer false-positive results. J. Thorac. Cardiovasc. Surg., April 1, 2008; 135(4): 816 - 822. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. E. Lee, J. Redwine, C. Foster, E. Abella, T. Lown, D. Lau, and D. Follette Mediastinoscopy might not be necessary in patients with non-small cell lung cancer with mediastinal lymph nodes having a maximum standardized uptake value of less than 5.3 J. Thorac. Cardiovasc. Surg., March 1, 2008; 135(3): 615 - 619. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Melek, M. Z. Gunluoglu, A. Demir, H. Akin, A. Olcmen, and S. I. Dincer Role of positron emission tomography in mediastinal lymphatic staging of non-small cell lung cancer Eur. J. Cardiothorac. Surg., February 1, 2008; 33(2): 294 - 299. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. C. Ung, D. E. Maziak, J. A. Vanderveen, C. A. Smith, K. Gulenchyn, C. Lacchetti, W. K. Evans, and Lung Cancer Disease Site Group of Cancer Care Onta 18Fluorodeoxyglucose Positron Emission Tomography in the Diagnosis and Staging of Lung Cancer: A Systematic Review J Natl Cancer Inst, December 5, 2007; 99(23): 1753 - 1767. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. A. Silvestri, M. K. Gould, M. L. Margolis, L. T. Tanoue, D. McCrory, E. Toloza, and F. Detterbeck Noninvasive Staging of Non-small Cell Lung Cancer: ACCP Evidenced-Based Clinical Practice Guidelines (2nd Edition) Chest, September 1, 2007; 132(3_suppl): 178S - 201S. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. C. Lee, J. L. Port, R. J. Korst, Y. Liss, D. N. Meherally, and N. K. Altorki Risk Factors for Occult Mediastinal Metastases in Clinical Stage I Non-Small Cell Lung Cancer Ann. Thorac. Surg., July 1, 2007; 84(1): 177 - 181. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. E. Lee, D. von Haag, T. Lown, D. Lau, R. Calhoun, and D. Follette Advances in positron emission tomography technology have increased the need for surgical staging in non-small cell lung cancer J. Thorac. Cardiovasc. Surg., March 1, 2007; 133(3): 746 - 752. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Singh, B. Camazine, Y. Jadhav, R. Gupta, P. Mukhopadhyay, A. Khan, R. Reddy, Q. Zheng, D. D. Smith, R. Khode, et al. Endoscopic Ultrasound As a First Test for Diagnosis and Staging of Lung Cancer: A Prospective Study Am. J. Respir. Crit. Care Med., February 15, 2007; 175(4): 345 - 354. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. L. Port, R. S. Andrade, M. A. Levin, R. J. Korst, P. C. Lee, D. E. Becker, and N. K. Altorki Positron emission tomographic scanning in the diagnosis and staging of non-small cell lung cancer 2 cm in size or less J. Thorac. Cardiovasc. Surg., December 1, 2005; 130(6): 1611 - 1615. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Cerfolio, A. S. Bryant, T. S. Winokur, B. Ohja, and A. A. Bartolucci Repeat FDG-PET After Neoadjuvant Therapy is a Predictor of Pathologic Response in Patients With Non-Small Cell Lung Cancer Ann. Thorac. Surg., December 1, 2004; 78(6): 1903 - 1909. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Cerfolio, B. Ojha, A. S. Bryant, V. Raghuveer, J. M. Mountz, and A. A. Bartolucci The accuracy of integrated PET-CT compared with dedicated pet alone for the staging of patients with nonsmall cell lung cancer Ann. Thorac. Surg., September 1, 2004; 78(3): 1017 - 1023. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Nomori, K. Watanabe, T. Ohtsuka, T. Naruke, K. Suemasu, and K. Uno The size of metastatic foci and lymph nodes yielding false-negative and false-positive lymph node staging with positron emission tomography in patients with lung cancer J. Thorac. Cardiovasc. Surg., April 1, 2004; 127(4): 1087 - 1092. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. G. Pfister, D. H. Johnson, C. G. Azzoli, W. Sause, T. J. Smith, S. Baker Jr, J. Olak, D. Stover, J. R. Strawn, A. T. Turrisi, et al. American Society of Clinical Oncology Treatment of Unresectable Non-Small-Cell Lung Cancer Guideline: Update 2003 J. Clin. Oncol., January 15, 2004; 22(2): 330 - 353. [Full Text] [PDF] |
||||
![]() |
M. K. Gould, W. G. Kuschner, C. E. Rydzak, C. C. Maclean, A. N. Demas, H. Shigemitsu, J. K. Chan, and D. K. Owens Test Performance of Positron Emission Tomography and Computed Tomography for Mediastinal Staging in Patients with Non-Small-Cell Lung Cancer: A Meta-Analysis Ann Intern Med, December 2, 2003; 139(11): 879 - 892. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Toker, Y. Bayrak, S. Tanju, S. Ziyade, O. Eroglu, D. Yilmazbayhan, S. Dilege, and G. Kalayci Invasive staging of superior mediastinum in non-small cell lung cancer patients with specific indications Interactive CardioVascular and Thoracic Surgery, December 1, 2003; 2(4): 472 - 476. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. V. Gonzalez-Stawinski, A. Lemaire, F. Merchant, E. O'Halloran, R. E. Coleman, D. H. Harpole, and T. A. D'Amico A comparative analysis of positron emission tomography and mediastinoscopy in staging non-small cell lung cancer J. Thorac. Cardiovasc. Surg., December 1, 2003; 126(6): 1900 - 1904. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. E. Reed, D. H. Harpole, K. E. Posther, S. L. Woolson, R. J. Downey, B. F. Meyers, R. T. Heelan, H. A. MacApinlac, S.-H. Jung, G. A. Silvestri, et al. Results of the American College of Surgeons Oncology Group Z0050 trial: the utility of positron emission tomography in staging potentially operable non-small cell lung cancer J. Thorac. Cardiovasc. Surg., December 1, 2003; 126(6): 1943 - 1951. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Cerfolio, B. Ojha, A. S. Bryant, C. S. Bass, A. A. Bartalucci, and J. M. Mountz The role of FDG-PET scan in staging patients with nonsmall cell carcinoma Ann. Thorac. Surg., September 1, 2003; 76(3): 861 - 866. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. K. LeBlanc, R. Espada, and G. Ergun Non-small Cell Lung Cancer Staging Techniques and Endoscopic Ultrasound: Tissue Is Still the Issue Chest, May 1, 2003; 123(5): 1718 - 1725. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Cerfolio, B. Ojha, S. Mukherjee, A. H. Pask, C. S. Bass, and C. R. Katholi Positron emission tomography scanning with 2-fluoro-2-deoxy-D-glucose as a predictor of response of neoadjuvant treatment for non-small cell carcinoma J. Thorac. Cardiovasc. Surg., April 1, 2003; 125(4): 938 - 944. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. M. Toloza, L. Harpole, and D. C. McCrory Noninvasive Staging of Non-small Cell Lung Cancer: A Review of the Current Evidence Chest, January 1, 2003; 123(1_suppl): 137S - 146S. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Eggeling, T. Martin, J. Bottger, T. Beinert, and K. Gellert Invasive staging of non-small cell lung cancer - a prospective study Eur. J. Cardiothorac. Surg., November 1, 2002; 22(5): 679 - 684. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |