Ann Thorac Surg 2000;70:1017-1020
© 2000 The Society of Thoracic Surgeons
a Pinnacle Health System, Harrisburg, Pennsylvania, USA
b Park Nicollet Heart Center, HealthSystem Minnesota, Minneapolis, Minnesota, USA
c Albert Einstein Medical Center, Philadelphia, Pennsylvania, USA
d Cardiac Surgical Associates, Minneapolis, Minnesota, USA
e Medical City Dallas, Dallas, Texas, USA
f Utrecht University Hospital, Utrecht, The Netherlands
Address reprint requests to Dr Hart, Capital Area Cardiovascular Surgical Institute, 423 N 21st St, Camp Hill, PA 17011
e-mail: jchart51{at}earthlink.net
Presented at the Sixth Annual Cardiothoracic Techniques and Technologies Meeting 2000, Ft Lauderdale, FL, Jan 2729, 2000.
Background. Off-pump coronary bypass may provide a safer form of surgical revascularization by avoiding the unwanted complications of cardiopulmonary bypass, particularly in the increasingly complex patients being referred for operation. This study reviews the entire experience of the Medtronic Octopus System (Medtronic, Minneapolis, MN) for beating heart bypass from 7 surgeons. Demographics, operative procedures, early outcomes, and trends in usage were examined.
Methods. Patients were selected for off-pump procedures by the individual surgeons. Data were entered prospectively into locally maintained databases and then collected for collation and analysis.
Results. A total of 1,582 consecutive Octopus patients were entered, representing the entire Octopus experience of each surgeon. Proportions of off-pump procedures relative to standard bypass increased over time, as did the percentage of patients receiving three or more grafts, 24.6% in 1997 and 55.9% in 1999. A total of 3,653 anastomoses were performed, 1,905 to the left anterior descending system, 837 to the circumflex distribution, and 911 to the right coronary territory. Morbidity was low. Few patients required conversion to cardiopulmonary bypass (2.6%; 0.2% urgently). Permanent stroke occurred in 0.6% and myocardial infarction in 1.2%. Operative mortality was 1%.
Conclusions. Octopus off-pump bypass was demonstrated to be a safe procedure with widening applicability. With experience surgeons tend to apply the system to increasing proportions of their patients and are able to revascularize all coronary territories.
This article has been cited by other articles:
![]() |
K. Nishiyama, M. Horiguchi, S. Shizuta, T. Doi, N. Ehara, R. Tanuguchi, Y. Haruna, Y. Nakagawa, Y. Furukawa, M. Fukushima, et al. Temporal Pattern of Strokes After On-Pump and Off-Pump Coronary Artery Bypass Graft Surgery. Ann. Thorac. Surg., June 1, 2009; 87(6): 1839 - 1844. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Fattouch, F. Guccione, P. Dioguardi, R. Sampognaro, E. Corrado, M. Caruso, and G. Ruvolo Off-pump versus on-pump myocardial revascularization in patients with ST-segment elevation myocardial infarction: a randomized trial. J. Thorac. Cardiovasc. Surg., March 1, 2009; 137(3): 650 - 656. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Emmiler, C. U. Kocogullari, Y. Ela, and A. Cekirdekci Influence of intracoronary shunt on myocardial damage: a prospective randomized study Eur. J. Cardiothorac. Surg., November 1, 2008; 34(5): 1000 - 1004. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. L. Hannan, C. Wu, C. R. Smith, R. S.D. Higgins, R. E. Carlson, A. T. Culliford, J. P. Gold, and R. H. Jones Off-Pump Versus On-Pump Coronary Artery Bypass Graft Surgery: Differences in Short-Term Outcomes and in Long-Term Mortality and Need for Subsequent Revascularization Circulation, September 4, 2007; 116(10): 1145 - 1152. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Ustunsoy, H. Kazaz, M. A Celkan, C. Kayiran, R. Hayta, and E. Bayar Deep Pericardial Suture vs Apical Suction for Off-Pump Bypass Grafting Asian Cardiovasc Thorac Ann, April 1, 2007; 15(2): 123 - 126. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. J. Ferreira-Gonzalez, A. Ribera, P. Cascant, G. Permanyer-Miralda, and for the ARCA study group Outcomes in off-pump vs. on-pump coronary artery bypass grafting stratified by pre-operative risk profile: an assessment using propensity score Eur. Heart J., October 2, 2006; 27(20): 2473 - 2480. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. C. Reeves, R. Ascione, M. Caputo, and G. D. Angelini Morbidity and mortality following acute conversion from off-pump to on-pump coronary surgery. Eur. J. Cardiothorac. Surg., June 1, 2006; 29(6): 941 - 947. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. I. Chernov, N. Yu. Efimova, I. Yu. Efimova, S. D. Akhmedov, and Y. B. Lishmanov Short-term and long-term cognitive function and cerebral perfusion in off-pump and on-pump coronary artery bypass patients Eur. J. Cardiothorac. Surg., January 1, 2006; 29(1): 74 - 81. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-F. Legare, K. J. Buth, and G. M. Hirsch Conversion to on pump from OPCAB is associated with increased mortality: results from a randomized controlled trial Eur. J. Cardiothorac. Surg., February 1, 2005; 27(2): 296 - 301. [Abstract] [Full Text] [PDF] |
||||
![]() |
N. C. Patel, N. U. Patel, D. F. Loulmet, J. C. McCabe, and V. A. Subramanian Emergency conversion to cardiopulmonary bypass during attempted off-pump revascularization results in increased morbidity and mortality J. Thorac. Cardiovasc. Surg., November 1, 2004; 128(5): 655 - 661. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y.L. Kwak, Y.J. Oh, S.H. Kim, H.K. Shin, J.Y. Kim, and Y.W. Hong Efficacy of pre-emptive milrinone in off-pump coronary artery bypass surgery: comparison between patients with a low and normal pre-graft cardiac index Eur. J. Cardiothorac. Surg., October 1, 2004; 26(4): 687 - 693. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. F. Grundeman, C. W. J. Verlaan, W. J. van Boven, and C. Borst Ninety-degree anterior cardiac displacement in off-pump coronary artery bypass grafting: the Starfish cardiac positioner preserves stroke volume and arterial pressure Ann. Thorac. Surg., August 1, 2004; 78(2): 679 - 684. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. G Raja and G. D Dreyfus Will off-pump coronary artery surgery replace conventional coronary artery surgery? J R Soc Med, June 1, 2004; 97(6): 275 - 278. [Full Text] [PDF] |
||||
![]() |
J.-F. Legare, K. J. Buth, S. King, J. Wood, J. A. Sullivan, C. H. Friesen, J. Lee, K. Stewart, and G. M. Hirsch Coronary Bypass Surgery Performed off Pump Does Not Result in Lower In-Hospital Morbidity Than Coronary Artery Bypass Grafting Performed on Pump Circulation, February 24, 2004; 109(7): 887 - 892. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. J. Racz, E. L. Hannan, O. W. Isom, V. A. Subramanian, R. H. Jones, J. P. Gold, T. J. Ryan, A. Hartman, A. T. Culliford, E. Bennett, et al. A comparison of short- and long-term outcomes after off-pump and on-pump coronary artery bypass graft surgery with sternotomy J. Am. Coll. Cardiol., February 18, 2004; 43(4): 557 - 564. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Filsoufi, R. S. Farivar, L. Aklog, C. A. Anderson, R. H. Chen, S. Lichtenstein, J. Zhang, and D. H. Adams Automated distal coronary bypass with a novel magnetic coupler (MVP system) J. Thorac. Cardiovasc. Surg., January 1, 2004; 127(1): 185 - 192. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. K. Song, R. J. Petersen, E. Sharoni, R. A. Guyton, and J. D. Puskas Safe evolution towards routine off-pump coronary artery bypass: negotiating the learning curve Eur. J. Cardiothorac. Surg., December 1, 2003; 24(6): 947 - 952. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Jacobs, D. Holzhey, B. B. Kiaii, J. F. Onnasch, T. Walther, F. W. Mohr, and V. Falk Limitations for manual and telemanipulator-assisted motion tracking--implications for endoscopic beating-heart surgery Ann. Thorac. Surg., December 1, 2003; 76(6): 2029 - 2035. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Hirose and A. Amano Stroke Rate of Off-pump Coronary Artery Bypass; Aortocoronary Bypass Versus in-Situ Bypass Angiology, November 1, 2003; 54(6): 647 - 653. [Abstract] [PDF] |
||||
![]() |
R A Archbold and N P Curzen Off-pump coronary artery bypass graft surgery: the incidence of postoperative atrial fibrillation Heart, October 1, 2003; 89(10): 1134 - 1137. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Hilker, H. Oelert, and U. Hake A review of 507 off-pump coronary bypass patients: a single center experience Interactive CardioVascular and Thoracic Surgery, September 1, 2003; 2(3): 246 - 250. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Kamiya, G. Watanabe, and T. Kanamori Flow simulation of the intracoronary shunt tube for off-pump coronary artery bypass Eur. J. Cardiothorac. Surg., May 1, 2003; 23(5): 665 - 669. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. D. Puskas, W. H. Williams, P. G. Duke, J. R. Staples, K. E. Glas, J. J. Marshall, M. Leimbach, P. Huber, S. Garas, B. H. Sammons, et al. Off-pump coronary artery bypass grafting provides complete revascularization with reduced myocardial injury, transfusion requirements, and length of stay: A prospective randomized comparison of two hundred unselected patients undergoing off-pump versus conventional coronary artery bypass grafting J. Thorac. Cardiovasc. Surg., April 1, 2003; 125(4): 797 - 808. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. Hart Maintaining hemodynamic stability and myocardial performance during off-pump coronary bypass surgery Ann. Thorac. Surg., February 1, 2003; 75(2): S740 - 744. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. M. Nathoe, D. van Dijk, E. W.L. Jansen, W. J.L. Suyker, J. C. Diephuis, W.-J. van Boven, A. B. de la Riviere, C. Borst, C. J. Kalkman, D. E. Grobbee, et al. A Comparison of On-Pump and Off-Pump Coronary Bypass Surgery in Low-Risk Patients N. Engl. J. Med., January 30, 2003; 348(5): 394 - 402. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Shimokawa, N. Minato, N. Yamada, Y. Takeda, Y. Hisamatsu, and M. Itoh Assessment of ascending aorta using epiaortic ultrasonography during off-pump coronary artery bypass grafting Ann. Thorac. Surg., December 1, 2002; 74(6): 2097 - 2100. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. A. Vassiliades Jr, J. L. Nielsen, and J. L. Lonquist Coronary perfusion methods during off-pump coronary artery bypass: results of a randomized clinical trial Ann. Thorac. Surg., October 1, 2002; 74(4): S1383 - 1389. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Mack, D. Bachand, T. Acuff, J. Edgerton, S. Prince, T. Dewey, and M. Magee Improved outcomes in coronary artery bypass grafting with beating-heart techniques J. Thorac. Cardiovasc. Surg., September 1, 2002; 124(3): 598 - 607. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. P T. de Jaegere and W. J L Suyker OFF-PUMP CORONARY ARTERY BYPASS SURGERY Heart, September 1, 2002; 88(3): 313 - 318. [Full Text] [PDF] |
||||
![]() |
V. Falk Manual control and tracking--a human factor analysis relevant for beating heart surgery Ann. Thorac. Surg., August 1, 2002; 74(2): 624 - 628. [Abstract] [Full Text] [PDF] |
||||
![]() |
X. M Mueller and L. K von Segesser Circulatory support for OPCAB procedures Perfusion, July 1, 2002; 17(4): 305 - 312. [Abstract] [PDF] |
||||
![]() |
L. I. Bonchek, D. van Dijk, P. P.T. de Jaegere, E. W.L. Jansen, H. M. Nathoe, J. C. Diephuis, C. Borst, E. Buskens, D. E. Grobbee, A. P. Nierich, et al. Off-Pump Versus On-Pump Coronary Bypass Surgery * Response Circulation, June 25, 2002; 105 (25): e198 - e198. [Full Text] [PDF] |
||||
![]() |
S. J. George, S. Al-Ruzzeh, and M. Amrani Mitral annulus distortion during beating heart surgery: a potential cause for hemodynamic disturbance--a three-dimensional echocardiography reconstruction study Ann. Thorac. Surg., May 1, 2002; 73(5): 1424 - 1430. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Van Dijk, E. W. L. Jansen, R. Hijman, A. P. Nierich, J. C. Diephuis, K. G. M. Moons, J. R. Lahpor, C. Borst, A. M. A. Keizer, H. M. Nathoe, et al. Cognitive Outcome After Off-Pump and On-Pump Coronary Artery Bypass Graft Surgery: A Randomized Trial JAMA, March 20, 2002; 287(11): 1405 - 1412. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Klein, R. Meijer, J. H. R. Eikelaar, P. F. Grundeman, and C. Borst Epicardial ultrasound in off-pump coronary artery bypass grafting: potential aid in intraoperative coronary diagnostics Ann. Thorac. Surg., March 1, 2002; 73(3): 809 - 812. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Riha, M. Danzmayr, G. Nagele, L. Mueller, D. Hoefer, H. Ott, G. Laufer, and J. Bonatti Off pump coronary artery bypass grafting in EuroSCORE high and low risk patients Eur. J. Cardiothorac. Surg., February 1, 2002; 21(2): 193 - 198. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. F. Grundeman, C. Borst, C. W.J. Verlaan, S. Damen, and S. Mertens Hemodynamic changes with right lateral decubitus body positioning in the tilted porcine heart Ann. Thorac. Surg., December 1, 2001; 72(6): 1991 - 1996. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Wolfe The coronary artery bypass conduit: II. Assessment of the quality of the distal anastomosis Ann. Thorac. Surg., December 1, 2001; 72(6): S2253 - 2258. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Hernandez, W. E. Cohn, Y. R. Baribeau, J. F. Tryzelaar, D. C. Charlesworth, R. A. Clough, J. D. Klemperer, J. R. Morton, B. M. Westbrook, E. M. Olmstead, et al. In-hospital outcomes of off-pump versus on-pump coronary artery bypass procedures: a multicenter experience Ann. Thorac. Surg., November 1, 2001; 72(5): 1528 - 1534. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. van Dijk, A. P. Nierich, E. W.L. Jansen, H. M. Nathoe, W. J.L. Suyker, J. C. Diephuis, W.-J. van Boven, C. Borst, E. Buskens, D. E. Grobbee, et al. Early Outcome After Off-Pump Versus On-Pump Coronary Bypass Surgery: Results From a Randomized Study Circulation, October 9, 2001; 104(15): 1761 - 1766. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J. Damiano Jr, H. A. Tabaie, M. J. Mack, J. R. Edgerton, C. Mullangi, W. P. Graper, and S. M. Prasad Initial prospective multicenter clinical trial of robotically-assisted coronary artery bypass grafting Ann. Thorac. Surg., October 1, 2001; 72(4): 1263 - 1269. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |