Ann Thorac Surg 2000;70:547-552
© 2000 The Society of Thoracic Surgeons
A Department of Cardiac Surgery, Oxford Heart Centre, The John Radcliffe Hospital, Oxford, England, GBR, UK
Address reprint requests to Dr Katsumata, Oxford Heart Centre, John Radcliffe Hospital, Oxford OX3 9DU, England
Background. Postoperative mediastinal false aneurysm is associated with a substantial morbidity and mortality. Surgical treatment is mandatory, although the individual approach varies according to the type of pathologic process, infection status, and site of origin of the aneurysm.
Methods. Between April 1993 and February 1999, we treated 10 patients, aged 25 to 73 years, with anastomotic mediastinal false aneurysm originating from the proximal thoracic aorta. Nine had undergone prior operations on the ascending aorta (7, type A dissection repair; 1, aortitis; 1, root abscess) with a Dacron conduit (n = 5) or valved conduit (n = 4). The last patient had undergone valve replacement for excavating aortic root sepsis. False aneurysms were detected from 2 to 70 months after the most recent operation. Three patients had positive tissue cultures. The surgical procedure was direct suture repair of the disrupted anastomosis in 5, root or ascending aortic replacement with an aortic homograft in 4, and Dacron graft interposition in 1. Hypothermic low-flow perfusion with or without circulatory arrest was used in all patients.
Results. There was one hospital death caused by staphylococcal mediastinitis. A false aneurysm recurred after direct suture repair in 2 patients with underlying type A dissection or aortitis. This resulted in one late death. One patient experienced a neurologic event during removal of an infected vascular graft. All 8 surviving patients are alive and well after a mean follow-up of 2 years. Three patients with mycotic false aneurysms remain free from infection after aortic homograft replacement.
Conclusions. Mediastinal false aneurysms are surgically taxing. Low-flow hypothermic perfusion with or without circulatory arrest allows safe reentry. Radical surgery provides a satisfactory outcome in infected patients. Local repair of suture dehiscence in pathologic tissues may predispose to recurrence. We suspect that excessive use of formalin in gelatin-resorcin-formol glue may predispose to tissue necrosis.
This article has been cited by other articles:
![]() |
P. Rispoli, G. Varetto, F. M. Savia, and M. Rinaldi Large post-stenting innominate artery pseudoaneurysm Interactive CardioVascular and Thoracic Surgery, June 1, 2008; 7(3): 444 - 446. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Gabbieri, P. M Dohmen, J. Linneweber, A. Lembcke, C. von Heymann, and W. F Konertz Mycotic Pseudoaneurysm of the Ascending Aorta at Site of Aortic Cannulation Asian Cardiovasc Thorac Ann, April 1, 2008; 16(2): e15 - e17. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Watanuki, H. Ogino, H. Matsuda, K. Minatoya, H. Sasaki, T. Fukuda, and S. Kitamura Dilatation of the Aneurysmal Sac After Total Arch Replacement Ann. Thorac. Surg., February 1, 2008; 85(2): 639 - 641. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Coppola, R. Bonifazi, M. Gucciardo, and P. Pantaleo Ruptured aortic arch aneurysm: transposition of aortic arch branches after insertion of thoracic endovascular stent with extra-anatomic brain perfusion Interactive CardioVascular and Thoracic Surgery, June 1, 2007; 6(3): 376 - 378. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Bachet, M. Pirotte, F. Laborde, and D. Guilmet Reoperation for Giant False Aneurysm of the Thoracic Aorta: How to Reenter the Chest? Ann. Thorac. Surg., May 1, 2007; 83(5): 1610 - 1614. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. F. Coutinho and M. J. Antunes Pseudoaneurysm of an Aortic Homograft Ann. Thorac. Surg., December 1, 2006; 82(6): 2280 - 2282. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. A. Atik, J. L. Navia, L. G. Svensson, P. R. Vega, J. Feng, M. E. Brizzio, A. M. Gillinov, B. G. Pettersson, E. H. Blackstone, and B. W. Lytle Surgical treatment of pseudoaneurysm of the thoracic aorta. J. Thorac. Cardiovasc. Surg., August 1, 2006; 132(2): 379 - 385. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Villavicencio, T. A. Orszulak, T. M. Sundt III, R. C. Daly, J. A. Dearani, C. G.A. McGregor, C. J. Mullany, F. J. Puga, K. J. Zehr, and H. V. Schaff Thoracic aorta false aneurysm: what surgical strategy should be recommended? Ann. Thorac. Surg., July 1, 2006; 82(1): 81 - 89. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Maselli, G. Santise, A. Montalto, and F. Musumeci Endovascular Aortic Clamping for Pseudoaneurysms of the Aortic Root With Aortic Regurgitation Ann. Thorac. Surg., October 1, 2005; 80(4): 1303 - 1308. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Okubo, J. Isobe, J. Kitamura, and Y. Ueno Mediastinitis and pseudoaneurysm of brachiocephalic artery long after the resection of invasive thymoma and postoperative irradiation J. Thorac. Cardiovasc. Surg., September 1, 2005; 130(3): 918 - 919. [Full Text] [PDF] |
||||
![]() |
B. Parihar, L. S. D. Choudhary, A. P. Madhu, M. K. Alpha, R. Thankachen, and V. Shukla Pseudoaneurysm of Ascending Aorta After Aortic Valve Replacement Ann. Thorac. Surg., February 1, 2005; 79(2): 705 - 707. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. Dumont, M. Carrier, R. Cartier, M. Pellerin, N. Poirier, D. Bouchard, and L. P. Perrault Repair of aortic false aneurysm using deep hypothermia and circulatory arrest Ann. Thorac. Surg., July 1, 2004; 78(1): 117 - 120. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. N. Messner, C. Vatcharasiritham, I. Gregoric, B. Radovancevic, P. Odegaard, S. D. Flamm, and O. H. Frazier Prosthetic graft remnant-related pseudoaneurysm after left ventricular assist device explantation: A case report J. Thorac. Cardiovasc. Surg., January 1, 2004; 127(1): 259 - 261. [Full Text] [PDF] |
||||
![]() |
A. Z. Apaydin, H. Posacioglu, F. Islamoglu, and A. Telli A practical tool to control bleeding during sternal reentry for pseudoaneurysm of the ascending aorta Ann. Thorac. Surg., March 1, 2003; 75(3): 1037 - 1038. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. W. Downing What are the risks of using biologic glues? Ann. Thorac. Surg., March 1, 2003; 75(3): 1063 - 1063. [Full Text] [PDF] |
||||
![]() |
K. Tanaka, H. Makuuchi, Y. Naruse, T. Kobayashi, I. Hayashi, T. Takayama, and Y. Namifusa False Aneurysm Due to Suture Loosening After Aortic Arch Replacement Asian Cardiovasc Thorac Ann, December 1, 2002; 10(4): 346 - 348. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Imanaka, S. Kyo, S. Takamoto, M. Kato, H. Tanabe, H. Ohuchi, H. Asano, and Y. Yokote Periannular abscess and aorta-left ventricular fistula after infection in the false lumen of an aortic dissection J. Thorac. Cardiovasc. Surg., October 1, 2002; 124(4): 841 - 843. [Full Text] [PDF] |
||||
![]() |
Y. Kawachi, A. Nakashima, T. Onzuka, and T. Yamauchi False aneurysm of the ascending aorta concomitant with chronic mediastinitis after tube graft replacement in octogenarian Eur. J. Cardiothorac. Surg., September 1, 2002; 22(3): 450 - 453. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Westaby, S. Saito, and T. Katsumata Acute type A dissection: conservative methods provide consistently low mortality Ann. Thorac. Surg., March 1, 2002; 73(3): 707 - 713. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Carrier, L. P. Perrault, M. Pellerin, R. Marchand, P. Auger, G. B. Pelletier, M. White, N. Racine, and D. Bouchard Sternal wound infection after heart transplantation: incidence and results with aggressive surgical treatment Ann. Thorac. Surg., September 1, 2001; 72(3): 719 - 723. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |