Ann Thorac Surg 2000;70:510-515
© 2000 The Society of Thoracic Surgeons
a Department of Cardiovascular Surgery, Hôpital de la Tour, Meyrin-Geneva, Switzerland
Address reprint requests to Dr Christenson, Department of Cardiovascular Surgery, Hôpital Cantonal Universitaires de Genève, Rue Micheli-du-Crest 24, CH-1211 Geneva, Switzerland;
e-mail: jtchristenson{at}hotmail.com
Background. The efficacy of preoperative intraaortic balloon pump therapy in high-risk coronary patients has been demonstrated earlier.
Methods. This study investigates the economic aspect by a detailed cost analysis of pooled information from two previously published randomized studies and 144 consecutive low-risk coronary artery bypass graft operations. Costs for patients receiving preoperative intraaortic balloon pump therapy before aortic cross-clamping (n = 62) were compared to those in a control group (n = 50). Detailed cost analysis was based on data provided by the hospital finance department.
Results. The total hospital costs were as follows: low-risk coronary artery bypass graft operations cost 35,335 ± 1,694 Swiss francs ($23,400 ± $1,121); high-risk coronary artery bypass graft without preoperative intraaortic balloon pump therapy cost 65,892 ± 31,719 Swiss francs ($43,637 ± $21,006); and high risk coronary artery bypass graft with preoperative intraaortic balloon pump therapy cost 41,948 ± 10,379 Swiss francs ($27,780 ± $6,874) (p = 0.0015). There were no significant differences in average cost among the preoperative intraaortic balloon pump therapy subgroups.
Conclusions. Preoperative intraaortic balloon pump therapy in high risk coronary patients is significantly cost-beneficial, With an average saving of 24,000 Swiss francs ($16,000) on the total hospital cost, a 36% cost reduction.
This article has been cited by other articles:
![]() |
Y. Takami and H. Masumoto Effects of Intra-Aortic Balloon Pumping on Graft Flow in Coronary Surgery: An Intraoperative Transit-Time Flowmetric Study Ann. Thorac. Surg., September 1, 2008; 86(3): 823 - 827. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. T Christenson, J. Sierra, J.-A. Romand, M. Licker, and A. Kalangos Long Intraaortic Balloon Treatment Time Leads to More Vascular Complications Asian Cardiovasc Thorac Ann, October 1, 2007; 15(5): 408 - 412. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. R. Ramnarine, A. D. Grayson, W. C. Dihmis, N. K. Mediratta, B. M. Fabri, and J. A.C. Chalmers Timing of intra-aortic balloon pump support and 1-year survival Eur. J. Cardiothorac. Surg., May 1, 2005; 27(5): 887 - 892. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Cohen, P. Urban, J. T. Christenson, D. L. Joseph, R. J. Freedman Jr, M. F. Miller, E.M. Ohman, R. C. Reddy, G. W. Stone, J. J. Ferguson III, et al. Intra-aortic balloon counterpulsation in US and non-US centres: results of the Benchmark(R) Registry Eur. Heart J., October 1, 2003; 24(19): 1763 - 1770. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. T Christenson Preoperative Intraaortic Balloon Pump for Salvage Myocardial Revascularization Asian Cardiovasc Thorac Ann, December 1, 2002; 10(4): 302 - 305. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. T. Christenson, M. Cohen, J. J. Ferguson III, R. J. Freedman, M. F. Miller, E. M. Ohman, R. C. Reddy, G. W. Stone, and P. M. Urban Trends in intraaortic balloon counterpulsation complications and outcomes in cardiac surgery Ann. Thorac. Surg., October 1, 2002; 74(4): 1086 - 1090. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. J.F. Baskett, W. A. Ghali, A. Maitland, and G. M. Hirsch The intraaortic balloon pump in cardiac surgery Ann. Thorac. Surg., October 1, 2002; 74(4): 1276 - 1287. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. T. Christenson and M. Cohen Preoperative IABP in high-risk patients reduces postoperative lactate release and subsequent mortality Ann. Thorac. Surg., March 1, 2002; 73(3): 1026 - 1027. [Full Text] [PDF] |
||||
![]() |
R. J.F. Baskett, G. M. Hirsch, and W. A. Ghati Preoperative intraaortic balloon pump in high-risk patients Ann. Thorac. Surg., April 1, 2001; 71(4): 1400 - 1400. [Full Text] [PDF] |
||||
![]() |
J. T. Christenson Preoperative intraaortic balloon pump in high-risk patients: Reply Ann. Thorac. Surg., April 1, 2001; 71(4): 1400 - 1401. [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |