ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Beat H. Walpoth
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Beldi, G.
Right arrow Articles by Walpoth, B. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Beldi, G.
Right arrow Articles by Walpoth, B. H.

Ann Thorac Surg 2000;70:212-217
© 2000 The Society of Thoracic Surgeons


Original articles: Cardiovascular

Transit time flow measurement: experimental validation and comparison of three different systems

Guido Beldi, MDa, Andreas Bosshard, MDa, Otto M. Hess, MDb, Ulrich Althaus, MDb, Beat H. Walpoth, MDa

a Department of Cardiovascular Surgery, University Hospital Insel, Bern, Switzerland
b Division of Cardiology, University Hospital Insel, Bern, Switzerland

Address reprint requests to Dr Walpoth, Department of Cardiovascular Surgery, University Hospital Insel, CH-3010, Bern, Switzerland
e-mail: beat.walpoth{at}insel.ch

Background. Bloodflow measurements are of major clinical importance for quality control in vascular surgery. They allow detection of low-flow situations which may influence outcome adversely. The purpose of the present study was to validate three different flow systems for measuring absolute blood flow.

Methods. Measurements were performed in an experimental flow model using arteries and veins and blood or saline at two different temperatures. As a reference method true flow was measured by volume sampling.

Results. Correlation coefficients between transit time flow and true flow measurements ranged between 0.71 and 0.92. Systematic overestimation and underestimation of transit time flow were observed, but after second-order correction all correlations were excellent, ranging from 0.93 to 0.95 irrespective of flow medium and temperature.

Conclusions. Transit time flow measurements are exact and reproducible. Second-order correction yields good accuracy and high precision, with minimal differences among the three systems evaluated.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
H. Nordgaard, N. Vitale, and R. Haaverstad
Transit-time blood flow measurements in sequential saphenous coronary artery bypass grafts.
Ann. Thorac. Surg., May 1, 2009; 87(5): 1409 - 1415.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
B. H. Walpoth, M. Schmid, A. Schwab, A. Bosshard, F. Eckstein, T. Carrel, and O. M. Hess
Vascular adaptation of the internal thoracic artery graft early and late after bypass surgery.
J. Thorac. Cardiovasc. Surg., October 1, 2008; 136(4): 876 - 883.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
G. D'Ancona, J. M. Hartman, F. Bartolozzi, E. van Deel, D. J.G.M. Duncker, A. J.J.C. Bogers, M. Pilato, and A. P. Kappetein
Epicardial coronary artery Doppler: validation in the animal model
Interactive CardioVascular and Thoracic Surgery, August 1, 2008; 7(4): 634 - 637.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J.-P. Verhoye, I. Abouliatim, A. Drochon, B. de Latour, C. Leclercq, A. Leguerrier, and H. Corbineau
Collateral blood flow between left coronary artery bypass grafts and chronically occluded right coronary circulation in patients with triple vessel disease.: Observations during complete revascularisation of beating hearts
Eur. J. Cardiothorac. Surg., January 1, 2007; 31(1): 49 - 54.
[Abstract] [Full Text] [PDF]


Home page
VASC ENDOVASCULAR SURGHome page
G. A. Winkler, K. D. Calligaro, S. Kolakowski, K. J. Doerr, S. McAffee-Bennett, K. Muller, and M. J. Dougherty
Comparison of Intraoperative Completion Flowmeter Versus Duplex Ultrasonography and Contrast Arteriography for Carotid Endarterectomy
Vascular and Endovascular Surgery, January 1, 2007; 40(6): 482 - 486.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. Di Giammarco, M. Pano, S. Cirmeni, P. Pelini, G. Vitolla, and M. Di Mauro
Predictive value of intraoperative transit-time flow measurement for short-term graft patency in coronary surgery.
J. Thorac. Cardiovasc. Surg., September 1, 2006; 132(3): 468 - 474.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
K.-B. Kim, C. H. Kang, and C. Lim
Prediction of Graft Flow Impairment by Intraoperative Transit Time Flow Measurement in Off-Pump Coronary Artery Bypass Using Arterial Grafts
Ann. Thorac. Surg., August 1, 2005; 80(2): 594 - 598.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
B. H. Walpoth
INVITED COMMENTARY
Ann. Thorac. Surg., March 1, 2005; 79(3): 857 - 858.
[Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
H. Kamiya, G. Watanabe, T. Saito, T. Doi, S. Tomita, H. Ohtake, and T. Kanamori
Real-time and continuous monitoring of myocardial blood flow using a thermal diffusion method
Eur. J. Cardiothorac. Surg., April 1, 2002; 21(4): 748 - 752.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. A. Wolfe
The coronary artery bypass conduit: II. Assessment of the quality of the distal anastomosis
Ann. Thorac. Surg., December 1, 2001; 72(6): S2253 - 2258.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2000 by The Society of Thoracic Surgeons.