ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Ole Lund
Hans K. Pilegaard
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lund, O.
Right arrow Articles by Pilegaard, H. K.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lund, O.
Right arrow Articles by Pilegaard, H. K.

Ann Thorac Surg 2000;69:1459-1465
© 2000 The Society of Thoracic Surgeons


Original articles: Cardiovascular

Standard aortic St. Jude valve at 18 years: performance profile and determinants of outcome

Ole Lund, MD, DSca, Sten Lyager Nielsen, MDa, Hanne Arildsen, MDb, Lars B. Ilkjaer, MDa, Hans K. Pilegaard, MDa

a Departments of Department of Thoracic and Cardiovascular Surgery, Aarhus University Hospital - Skejby Sygehus, Aarhus, Denmark
b Department of Cardiology, Skejby Sygehus, Aarhus University Hospital, Aarhus, Denmark

Address reprint requests to Dr Lund, Department of Cardio-Thoracic Surgery, Copenhagen University Hospital in Gentofte, Niels Andersens Vej 65, DK-2900 Hellerup, Denmark
e-mail: olund{at}thorax.dk

Background. The standard St. Jude disc valve has been in use for 20 years and remains the dominant mechanical valve of today. With nearly 19 years of follow-up, the present large series could indicate the performance profile and its determinants in the very long term.

Methods. A detailed follow-up was performed to a maximum of 18.6 years in 694 patients aged 15 to 83 years who undervent aortic valve replacement (AVR) with the standard St. Jude valve during 1980 to 1993. The Cox regression analysis was used to identify independent determinants of outcome in the aortic stenosis (n = 490) and regurgitation (n = 204) groups.

Results. Overall survival was 58%, 39%, and 37% at 10, 15, and 18 years, respectively. Only 12% of deaths (0.60%/patient-year) were related to the valve with a 15-year freedom of 91%. Embolism (1.18%/patient-year) and anticoagulant-related bleeding (2.24%/patient-year) were the dominant complications with 10-year/15-year freedoms of 90%/80% and 85%/72%, respectively. Only 24% of bleeding events were classified as major. Valve thrombosis occurred in 2 patients (0.04%/patient-year): 1 did not receive vitamin K antagonist treatment and International Normalized Ratio was below target level in the other. There were no mechanical failures. Endocarditis (0.42%/patient-year) and paravalvular leak (0.42%/patient-year) occurred with 15-year freedoms of 92% and 96%, respectively, with a relation between the latter (but not the former) and preoperative endocarditis in the regurgitation group. Freedom from serious complications (2.33%/patient-year) and all complications joined (4.33%/patient-year) were 72% and 54%, respectively, at 15 years with a 96% freedom from redo AVR (0.36%/patient-year). Age- and heart-related variables were independent risk factors for mortality, thromboembolism, bleeding, serious complications, and all complications joined. Small valve (19 and 21 mm) adversely affected serious and all complications in the regurgitation group.

Conclusions. With a follow-up approaching 2 decades and exhibiting a low rate of valve-related deaths, acceptable low thrombogenicity, and abscence of mechanical failure, the standard aortic St. Jude disc valve sets the standard for contemporary mechanical valves.




This article has been cited by other articles:


Home page
Card Surg AdultHome page
R. W. Emery, A. M. Emery, A. Knutsen, and G. V. Raikar
Aortic Valve Replacement with a Mechanical Cardiac Valve Prosthesis
Card. Surg. Adult, January 1, 2008; 3(2008): 841 - 856.
[Full Text]


Home page
CirculationHome page
J. L. Svennevig, M. Abdelnoor, and S. Nitter-Hauge
Twenty-Five Year Experience With the Medtronic-Hall Valve Prosthesis in the Aortic Position: A Follow-Up Cohort Study of 816 Consecutive Patients
Circulation, October 16, 2007; 116(16): 1795 - 1800.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
J.-P. Verhoye, I. Abouliatim, B. Lelong, A. Ingels, X. Roques, J. Pierre Villemot, T. Langanay, and A. Leguerrier
Edwards Mira bileaflet prosthesis in aortic position: midterm results of a prospective multi-centre study
Interactive CardioVascular and Thoracic Surgery, August 1, 2007; 6(4): 458 - 461.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. Baykut, L. Grize, C. Schindler, A. S. Keil, F. Bernet, and H.-R. Zerkowski
Eleven-year single-center experience with the ATS Open Pivot Bileaflet heart valve.
Ann. Thorac. Surg., September 1, 2006; 82(3): 847 - 852.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
O. Lund and M. Bland
Risk-corrected impact of mechanical versus bioprosthetic valves on long-term mortality after aortic valve replacement
J. Thorac. Cardiovasc. Surg., July 1, 2006; 132(1): 20 - 26.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
F. Bakhtiary, M. Schiemann, O. Dzemali, T. Wittlinger, M. Doss, H. Ackermann, A. Moritz, and P. Kleine
Stentless bioprostheses improve postoperative coronary flow more than stented prostheses after valve replacement for aortic stenosis
J. Thorac. Cardiovasc. Surg., April 1, 2006; 131(4): 883 - 888.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Josa, M. Castella, C. Pare, J. L. Bedini, R. Cartana, C. A. Mestres, J. L. Pomar, and J. Mulet
Hemolysis in Mechanical Bileaflet Prostheses: Experience With the Bicarbon Valve
Ann. Thorac. Surg., April 1, 2006; 81(4): 1291 - 1296.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. W. Emery, C. C. Krogh, K. V. Arom, A. M. Emery, K. Benyo-Albrecht, L. D. Joyce, and D. M. Nicoloff
The St. Jude Medical Cardiac Valve Prosthesis: A 25-Year Experience With Single Valve Replacement
Ann. Thorac. Surg., March 1, 2005; 79(3): 776 - 782.
[Abstract] [Full Text] [PDF]


Home page
HeartHome page
J P A Puvimanasinghe, J J M Takkenberg, M B Edwards, M J C Eijkemans, E W Steyerberg, L A van Herwerden, K M Taylor, G L Grunkemeier, J D F Habbema, and A J J C Bogers
Comparison of outcomes after aortic valve replacement with a mechanical valve or a bioprosthesis using microsimulation
Heart, October 1, 2004; 90(10): 1172 - 1178.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
O. Lund
Invited commentary
Ann. Thorac. Surg., July 1, 2004; 78(1): 83 - 84.
[Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
J. S. Ikonomidis, J. M. Kratz, A. J. Crumbley III, M. R. Stroud, S. M. Bradley, R. M. Sade, and F. A. Crawford Jr
Twenty-year experience with the St Jude Medical mechanical valve prosthesis
J. Thorac. Cardiovasc. Surg., December 1, 2003; 126(6): 2022 - 2031.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
S. H. Rahimtoola
Choice of prosthetic heart valve for adult patients
J. Am. Coll. Cardiol., March 19, 2003; 41(6): 893 - 904.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. L. Grunkemeier and Y. Wu
"Our complication rates are lower than theirs": Statistical critique of heart valve comparisons
J. Thorac. Cardiovasc. Surg., February 1, 2003; 125(2): 290 - 300.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
D. R. Clarke
Presidential address: Value, viability, and valves
J. Thorac. Cardiovasc. Surg., July 1, 2002; 124(1): 1 - 6.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. Gelsomino, G. Morocutti, P. Da Col, R. Frassani, R. Carella, G. Minen, and U. Livi
Preliminary experience with the St. Jude Medical Regent mechanical heart valve in the aortic position: early in vivo hemodynamic results
Ann. Thorac. Surg., June 1, 2002; 73(6): 1830 - 1836.
[Abstract] [Full Text] [PDF]


Home page
Eur Heart J SupplHome page
J.J.M. Takkenberg, J.P.A. Puvimanasinghe, L.A. van Herwerden, E.W. Steyerberg, M.J.C. Eijkemans, J.D.F Habbema, and A.J.J.C. Bogers
Prognosis after aortic valve replacement with St. Jude Medical bileaflet prostheses: impact on outcome of varying thromboembolic and bleeding hazards
Eur. Heart J. Suppl., December 1, 2001; 3(suppl_Q): Q27 - Q32.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2000 by The Society of Thoracic Surgeons.