|
|
||||||||
Ann Thorac Surg 2000;69:1459-1465
© 2000 The Society of Thoracic Surgeons
a Departments of Department of Thoracic and Cardiovascular Surgery, Aarhus University Hospital - Skejby Sygehus, Aarhus, Denmark
b Department of Cardiology, Skejby Sygehus, Aarhus University Hospital, Aarhus, Denmark
Address reprint requests to Dr Lund, Department of Cardio-Thoracic Surgery, Copenhagen University Hospital in Gentofte, Niels Andersens Vej 65, DK-2900 Hellerup, Denmark
e-mail: olund{at}thorax.dk
Background. The standard St. Jude disc valve has been in use for 20 years and remains the dominant mechanical valve of today. With nearly 19 years of follow-up, the present large series could indicate the performance profile and its determinants in the very long term.
Methods. A detailed follow-up was performed to a maximum of 18.6 years in 694 patients aged 15 to 83 years who undervent aortic valve replacement (AVR) with the standard St. Jude valve during 1980 to 1993. The Cox regression analysis was used to identify independent determinants of outcome in the aortic stenosis (n = 490) and regurgitation (n = 204) groups.
Results. Overall survival was 58%, 39%, and 37% at 10, 15, and 18 years, respectively. Only 12% of deaths (0.60%/patient-year) were related to the valve with a 15-year freedom of 91%. Embolism (1.18%/patient-year) and anticoagulant-related bleeding (2.24%/patient-year) were the dominant complications with 10-year/15-year freedoms of 90%/80% and 85%/72%, respectively. Only 24% of bleeding events were classified as major. Valve thrombosis occurred in 2 patients (0.04%/patient-year): 1 did not receive vitamin K antagonist treatment and International Normalized Ratio was below target level in the other. There were no mechanical failures. Endocarditis (0.42%/patient-year) and paravalvular leak (0.42%/patient-year) occurred with 15-year freedoms of 92% and 96%, respectively, with a relation between the latter (but not the former) and preoperative endocarditis in the regurgitation group. Freedom from serious complications (2.33%/patient-year) and all complications joined (4.33%/patient-year) were 72% and 54%, respectively, at 15 years with a 96% freedom from redo AVR (0.36%/patient-year). Age- and heart-related variables were independent risk factors for mortality, thromboembolism, bleeding, serious complications, and all complications joined. Small valve (19 and 21 mm) adversely affected serious and all complications in the regurgitation group.
Conclusions. With a follow-up approaching 2 decades and exhibiting a low rate of valve-related deaths, acceptable low thrombogenicity, and abscence of mechanical failure, the standard aortic St. Jude disc valve sets the standard for contemporary mechanical valves.
This article has been cited by other articles:
![]() |
R. W. Emery, A. M. Emery, A. Knutsen, and G. V. Raikar Aortic Valve Replacement with a Mechanical Cardiac Valve Prosthesis Card. Surg. Adult, January 1, 2008; 3(2008): 841 - 856. [Full Text] |
||||
![]() |
J. L. Svennevig, M. Abdelnoor, and S. Nitter-Hauge Twenty-Five Year Experience With the Medtronic-Hall Valve Prosthesis in the Aortic Position: A Follow-Up Cohort Study of 816 Consecutive Patients Circulation, October 16, 2007; 116(16): 1795 - 1800. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.-P. Verhoye, I. Abouliatim, B. Lelong, A. Ingels, X. Roques, J. Pierre Villemot, T. Langanay, and A. Leguerrier Edwards Mira bileaflet prosthesis in aortic position: midterm results of a prospective multi-centre study Interactive CardioVascular and Thoracic Surgery, August 1, 2007; 6(4): 458 - 461. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Baykut, L. Grize, C. Schindler, A. S. Keil, F. Bernet, and H.-R. Zerkowski Eleven-year single-center experience with the ATS Open Pivot Bileaflet heart valve. Ann. Thorac. Surg., September 1, 2006; 82(3): 847 - 852. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Lund and M. Bland Risk-corrected impact of mechanical versus bioprosthetic valves on long-term mortality after aortic valve replacement J. Thorac. Cardiovasc. Surg., July 1, 2006; 132(1): 20 - 26. [Abstract] [Full Text] [PDF] |
||||
![]() |
F. Bakhtiary, M. Schiemann, O. Dzemali, T. Wittlinger, M. Doss, H. Ackermann, A. Moritz, and P. Kleine Stentless bioprostheses improve postoperative coronary flow more than stented prostheses after valve replacement for aortic stenosis J. Thorac. Cardiovasc. Surg., April 1, 2006; 131(4): 883 - 888. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Josa, M. Castella, C. Pare, J. L. Bedini, R. Cartana, C. A. Mestres, J. L. Pomar, and J. Mulet Hemolysis in Mechanical Bileaflet Prostheses: Experience With the Bicarbon Valve Ann. Thorac. Surg., April 1, 2006; 81(4): 1291 - 1296. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. W. Emery, C. C. Krogh, K. V. Arom, A. M. Emery, K. Benyo-Albrecht, L. D. Joyce, and D. M. Nicoloff The St. Jude Medical Cardiac Valve Prosthesis: A 25-Year Experience With Single Valve Replacement Ann. Thorac. Surg., March 1, 2005; 79(3): 776 - 782. [Abstract] [Full Text] [PDF] |
||||
![]() |
J P A Puvimanasinghe, J J M Takkenberg, M B Edwards, M J C Eijkemans, E W Steyerberg, L A van Herwerden, K M Taylor, G L Grunkemeier, J D F Habbema, and A J J C Bogers Comparison of outcomes after aortic valve replacement with a mechanical valve or a bioprosthesis using microsimulation Heart, October 1, 2004; 90(10): 1172 - 1178. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Lund Invited commentary Ann. Thorac. Surg., July 1, 2004; 78(1): 83 - 84. [Full Text] [PDF] |
||||
![]() |
J. S. Ikonomidis, J. M. Kratz, A. J. Crumbley III, M. R. Stroud, S. M. Bradley, R. M. Sade, and F. A. Crawford Jr Twenty-year experience with the St Jude Medical mechanical valve prosthesis J. Thorac. Cardiovasc. Surg., December 1, 2003; 126(6): 2022 - 2031. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. H. Rahimtoola Choice of prosthetic heart valve for adult patients J. Am. Coll. Cardiol., March 19, 2003; 41(6): 893 - 904. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. L. Grunkemeier and Y. Wu "Our complication rates are lower than theirs": Statistical critique of heart valve comparisons J. Thorac. Cardiovasc. Surg., February 1, 2003; 125(2): 290 - 300. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. R. Clarke Presidential address: Value, viability, and valves J. Thorac. Cardiovasc. Surg., July 1, 2002; 124(1): 1 - 6. [Full Text] [PDF] |
||||
![]() |
S. Gelsomino, G. Morocutti, P. Da Col, R. Frassani, R. Carella, G. Minen, and U. Livi Preliminary experience with the St. Jude Medical Regent mechanical heart valve in the aortic position: early in vivo hemodynamic results Ann. Thorac. Surg., June 1, 2002; 73(6): 1830 - 1836. [Abstract] [Full Text] [PDF] |
||||
![]() |
J.J.M. Takkenberg, J.P.A. Puvimanasinghe, L.A. van Herwerden, E.W. Steyerberg, M.J.C. Eijkemans, J.D.F Habbema, and A.J.J.C. Bogers Prognosis after aortic valve replacement with St. Jude Medical bileaflet prostheses: impact on outcome of varying thromboembolic and bleeding hazards Eur. Heart J. Suppl., December 1, 2001; 3(suppl_Q): Q27 - Q32. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |