Ann Thorac Surg 2000;69:877-880
© 2000 The Society of Thoracic Surgeons
a Division of Cardiothoracic Surgery, Heart Institute for Children, Hope Childrens Hospital, Oak Lawn, Illinois, USA
b The University of Illinois at Chicago, Chicago, Illinois, USA
Address reprint requests to Dr Allen, Heart Institute for Children, Hope Childrens Hospital, 4440 W 95th St, Oak Lawn, IL 60453
Background. Coarctation repair in neonates or small infants, using a subclavian patch, has a relatively high risk of restenosis, especially if complicated by the presence of a short subclavian artery or long coarctation segment. We introduce a technical modification that facilitates the use of a subclavian flap, and decreases the restenosis rate in this subgroup of patients. It consists of a side-to-side transverse aortic anastomosis at the level of the coarctation, which widens the coarctation segment, shortens the isthmus, and pulls the distal end of the aortotomy proximally, allowing a tension-free subclavian flap aortoplasty.
Methods. Fifty-three consecutive neonates or infants less than 18 weeks old, with complex coarctation, underwent repair using this technique. Mean age was 26 ± 3 days and 36 patients (68%) were less than 28 days old. Weights ranged from 1.4 to 6.4 kg (mean 3.4 ± 0.2 kg), and 26 patients had other cardiac anomalies. Preoperative gradient by Doppler measurement ranged from 25 to 90 mm Hg (mean 49 ± 2 mm Hg).
Results. Mean aortic cross-clamp time was 27 ± 1 minutes (range 19 to 34 minutes). There were no deaths or surgical complications. Follow-up echocardiogram 4 to 52 months postoperatively (mean 25 ± 2 months) demonstrated no significant pressure gradient (less than 20 mm Hg) in 51 of 53 patients (96%), and a significant gradient in 2 patients (4%), which was subsequently corrected with balloon angioplasty.
Conclusions. The technical modification described shortens the isthmus, and thus allows for a longer aortotomy distal to the area of coarctation resulting in a tension-free repair especially in patients with a short subclavian artery. It also widens the area of coarctation, and as a result leads to a lower early recoarctation rate in this high-risk group. With increasing emphasis on the need for a longer aortotomy to prevent restenosis, this modification will have increasing application, especially in the neonatal population.
Related Article
Ann. Thorac. Surg. 2000 69: 881.
This article has been cited by other articles:
![]() |
C. D. Sudarshan, A. D. Cochrane, Z. H. Jun, R. Soto, and C. P. Brizard Repair of coarctation of the aorta in infants weighing less than 2 kilograms. Ann. Thorac. Surg., July 1, 2006; 82(1): 158 - 163. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Bhutta and A. Nasim Left arm pain 22 years after repair of aortic coarctation J R Soc Med, June 1, 2004; 97(6): 283 - 284. [Full Text] [PDF] |
||||
![]() |
V. E. Hjortdal, S. Khambadkone, M. R. de Leval, and V. T. Tsang Implications of anomalous right subclavian artery in the repair of neonatal aortic coarctation Ann. Thorac. Surg., August 1, 2003; 76(2): 572 - 575. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |