ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Stefan Thelin
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Olsson, C.
Right arrow Articles by Thelin, S.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Olsson, C.
Right arrow Articles by Thelin, S.
Related Collections
Right arrowRelated Article

Ann Thorac Surg 2000;69:743-749
© 2000 The Society of Thoracic Surgeons


Original Articles

No benefit of reduced heparinization in thoracic aortic operation with heparin-coated bypass circuits

Christian Olsson, MDa, Agneta Siegbahn, MD, PhDb, Eric Haldén, MD, PhDc, Bo Nilsson, MD, PhDd, Per Venge, MD, PhDb, Stefan Thelin, MD, PhDa

a Department of Cardiothoracic Surgery, Uppsala University Hospital, Uppsala, Sweden
b Department of Clinical Chemistry, Uppsala University Hospital, Uppsala, Sweden
c Department of Cardiothoracic Anesthesia, Uppsala University Hospital, Uppsala, Sweden
d Department of Clinical Immunology, Uppsala University Hospital, Uppsala, Sweden

Address reprint requests to Dr Thelin, Department of Cardiothoracic Surgery, Uppsala University Hospital, S-751 85 Uppsala, Sweden
e-mail: stefan.thelin{at}thorax.uas.lul.se

Background. Heparin coating of the cardiopulmonary bypass circuit attenuates inflammatory response and confer clinical benefits in cardiac operations. The positive effects may be amplified with reduced systemic heparin dosage. We studied markers of inflammation and coagulation in thoracic aortic operations with heparin-coated circuits and standard vs reduced systemic heparinization.

Methods. Thirty patients were randomized to standard (group S; 300 IU/kg initially; activated clotting times [ACT] > 480 seconds; 5,000 IU in prime; n = 16) or reduced (group R; 100 IU/kg initially; ACT > 250 seconds; 2,500 IU in prime; n = 14) dose systemic heparin. The following markers were analyzed perioperatively: (a) inflammatory response; acute phase cytokine interleukin-6, and granulocytic proteins myeloperoxidase and lactoferrin; (b) complement activation; factor C3a and the C5a-9 terminal complement complex [TCC]; and (c) coagulation; thrombin-antithrombin III complex.

Results. The clinical outcome did not differ between groups. Four (29%) patients in group R had a perioperative thromboembolic event. All studied markers were significantly elevated during and throughout cardiopulmonary bypass in both groups. Maximal values were higher in group R for all variables except for TCC. There were no statistically significant intergroup differences regarding markers of inflammation, complement activation, or coagulation activation.

Conclusions. The blood trauma in thoracic aortic operation is extensive, as reflected by the elevation of the studied biochemical markers, even when heparin-coated cardiopulmonary bypass circuits are used. In this study, we did not detect any benefits, either biochemical or clinical, of reducing the dose of systemic heparin.


Related Article

Richard J. Shemin
Ann. Thorac. Surg. 2000 69: 749. [Extract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
O. Mangoush, S. Purkayastha, S. Haj-Yahia, J. Kinross, M. Hayward, F. Bartolozzi, A. Darzi, and T. Athanasiou
Heparin-bonded circuits versus nonheparin-bonded circuits: an evaluation of their effect on clinical outcomes
Eur. J. Cardiothorac. Surg., June 1, 2007; 31(6): 1058 - 1069.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
The Society of Thoracic Surgeons Blood Conservatio, V. A. Ferraris, S. P. Ferraris, S. P. Saha, E. A. Hessel II, C. K. Haan, B. D. Royston, C. R. Bridges, R. S.D. Higgins, G. Despotis, et al.
Perioperative Blood Transfusion and Blood Conservation in Cardiac Surgery: The Society of Thoracic Surgeons and The Society of Cardiovascular Anesthesiologists Clinical Practice Guideline
Ann. Thorac. Surg., May 1, 2007; 83(5_Supplement): S27 - S86.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Johnell, G. Elgue, R. Larsson, A. Larsson, S. Thelin, and A. Siegbahn
Coagulation, fibrinolysis, and cell activation in patients and shed mediastinal blood during coronary artery bypass grafting with a new heparin-coated surface
J. Thorac. Cardiovasc. Surg., August 1, 2002; 124(2): 321 - 332.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
D. Paparella, T.M. Yau, and E. Young
Cardiopulmonary bypass induced inflammation: pathophysiology and treatment. An update
Eur. J. Cardiothorac. Surg., February 1, 2002; 21(2): 232 - 244.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
E. A. Hessel
Bypass Techniques for Descending Thoracic Aortic Surgery
Seminars in Cardiothoracic and Vascular Anesthesia, November 1, 2001; 5(4): 293 - 320.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2000 by The Society of Thoracic Surgeons.