ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Paulo M. Pêgo-Fernandes
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Pêgo-Fernandes, P. M.
Right arrow Articles by Jatene, A. D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Pêgo-Fernandes, P. M.
Right arrow Articles by Jatene, A. D.

Ann Thorac Surg 2000;69:536-540
© 2000 The Society of Thoracic Surgeons


Original Articles

Influence of biopump with and without intraaortic balloon on the coronary and carotid flow

Paulo M. Pêgo-Fernandes, MD, PhDa, Noedir A.G. Stolf, MD, PhDa, Luiz Felipe P. Moreira, MD, PhDa, Helio A. Fabri, MDa, Adolfo A. Leirner, MD, PhDa, Sergio A. Oliveira, MD, PhDa, Adib D. Jatene, MD, PhDa

a Heart Institute of University of São Paulo Medical School, São Paulo, Brazil

Address reprint requests to Dr Pêgo-Fernandes, Instituto do Coração do Hospital das Clínicas da Universidade de São Paulo, Divisão Cirúrgica, 2nd andar Av Dr Eneas de Carvalho Aguiar, 44, São Paulo-SP, Brazil, CEP 05403-000
e-mail: paulopego{at}incor.usp.br

Background. The objective of this study was to evaluate the influence of biopump used for left ventricular assistance on the coronary and carotid flows in dogs with normal heart. The efficacy of the simultaneous use of an intraaortic balloon pump to compensate the possible deleterious effects of the circulatory assistance with continuous flow was also analyzed.

Methods. Fifteen dogs were studied. The hemodynamic evaluation included serial measurements of the classic parameters. Carotid and coronary blood flows were obtained by electromagnetic transducers.

Results. The hemodynamic evaluation did not show significant statistical changes. The use of circulatory-isolated assistance with biopump shows reduction (24.6% ± 6.1%) in coronary flow, in relation to the control situation and the concomitant use of biopump and intraaortic balloon pump showed similar coronary flow. Regarding carotid flow, a similar trend was observed in relation to the positive influence of the pulsatile flow with an intraaortic balloon pump without statistical significance (p = 0.0582).

Conclusions. The biopump reduces the coronary flow in dogs. The use of intraaortic balloon pump with the biopump increases the coronary flow significantly, reaching similar values to those observed without the circulatory assistance.




This article has been cited by other articles:


Home page
Eur. J. Cardiothorac. Surg.Home page
Y. Ootaki, K. Kamohara, M. Akiyama, F. Zahr, M. W. Kopcak Jr., R. Dessoffy, and K. Fukamachi
Phasic coronary blood flow pattern during a continuous flow left ventricular assist support
Eur. J. Cardiothorac. Surg., November 1, 2005; 28(5): 711 - 716.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2000 by The Society of Thoracic Surgeons.