ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Sezai, A.
Right arrow Articles by Sezai, Y.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Sezai, A.
Right arrow Articles by Sezai, Y.

Ann Thorac Surg 2000;69:507-512
© 2000 The Society of Thoracic Surgeons


Original Articles

Evaluation of valve sound and its effects on ATS prosthetic valves in patients’ quality of life

Akira Sezai, MDa, Motomi Shiono, MDa, Yukihiko Orime, MDa, Hiroaki Hata, MDa, Shinya Yagi, MDa, Nanao Negishi, MDa, Yukiyasu Sezai, MDa

a Second Department of Surgery, Nihon University School of Medicine, Tokyo, Japan

Address reprint requests to Dr Akira Sezai, Second Department of Surgery, Nihon University School of Medicine, 30-1 Oyaguchi-kamimachi, Itabashi-ku, Tokyo, 173-8610, Japan

Background. We interviewed patients and carried out frequency analyses to compare the closing sounds of ATS and St. Jude Medical (SJM) prosthetic valves.

Methods. Forty-five patients undergoing valve replacements using ATS valves were investigated. We interviewed patients at 1 month and 1 year after the operation, and carried out frequency analysis to investigate the prosthetic valve’s closing sound.

Results. According to the results of the interviews, 84.4% of patients with ATS valves were not aware of the valve sounds. ATS valves scored significantly lower than SJM valves on audibility of the valve sound, disturbance during daytime, sleep disturbance, request for replacement with a soundless prosthetic valve, audibility to others, and noise index. According to the frequency analysis on the prosthetic valve’s closing sound, the sound peak of the ATS valves was around 1.2 kHz, and the sound pressure of the ATS valves was significantly lower than that of the SJM valves.

Conclusions. Though a further long-term observation on thromboembolism and hemolysis is needed for evaluation of prosthetic valves, the ATS valve is presently considered to impart a better quality of life.




This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
A. Sezai, M. Hata, T. Niino, I. Yoshitake, Y. Kasamaki, A. Hirayama, and K. Minami
Fifteen years of experience with ATS mechanical heart valve prostheses
J. Thorac. Cardiovasc. Surg., June 1, 2010; 139(6): 1494 - 1500.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
R. W. Emery, A. M. Emery, A. Knutsen, and G. V. Raikar
Aortic Valve Replacement with a Mechanical Cardiac Valve Prosthesis
Card. Surg. Adult, January 1, 2008; 3(2008): 841 - 856.
[Full Text]


Home page
Card Surg AdultHome page
T. Gudbjartsson, T. Absi, and S. Aranki
Mitral Valve Replacement
Card. Surg. Adult, January 1, 2008; 3(2008): 1031 - 1068.
[Full Text]


Home page
Ann. Thorac. Surg.Home page
D. Baykut, L. Grize, C. Schindler, A. S. Keil, F. Bernet, and H.-R. Zerkowski
Eleven-year single-center experience with the ATS Open Pivot Bileaflet heart valve.
Ann. Thorac. Surg., September 1, 2006; 82(3): 847 - 852.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
C. Stefanidis, A. M. Nana, D. De Canniere, M. Antoine, J.-L. Jansens, C.-H. Huynh, and J.-L. Le Clerc
10-Year Experience With the ATS Mechanical Valve in the Mitral Position
Ann. Thorac. Surg., June 1, 2005; 79(6): 1934 - 1938.
[Abstract] [Full Text] [PDF]


Home page
Eur J Cardiothorac SurgHome page
H. Koertke, A. Hoffmann-Koch, D. Boethig, K. Minami, T. Breymann, M. El-Arousy, D. Seifert, and R. Koerfer
Does the noise of mechanical heart valve prostheses affect quality of life as measured by the SF-36(R) questionnaire?
Eur J Cardiothorac Surg, July 1, 2003; 24(1): 52 - 58.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
R. W. Emery, G. J. Van Nooten, and P. J. Tesar
The initial experience with the ATS Medical mechanical cardiac valve prosthesis
Ann. Thorac. Surg., February 1, 2003; 75(2): 444 - 452.
[Abstract] [Full Text] [PDF]


Home page
Card Surg AdultHome page
T. Gudbjartsson, S. Aranki, and L. H. Cohn
Mechanical/Bioprosthetic Mitral Valve Replacement
Card. Surg. Adult, January 1, 2003; 2(2003): 951 - 986.
[Full Text]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 2000 by The Society of Thoracic Surgeons.