Ann Thorac Surg 1999;68:1384-1390
© 1999 The Society of Thoracic Surgeons
a Schools of Biomedical and Chemical Engineering, Atlanta, Georgia, USA
b Petit Institute for Bioengineering and Bioscience, Atlanta, Georgia, USA
c Georgia Institute of Technology, Atlanta, Georgia, USA
d Department of Biomedical Engineering, University of North Carolina at Chapel Hill, Chapel Hill, North Carolina, USA
Address reprint requests to Dr Yoganathan, Department of Biomedical Engineering, Georgia Institute Technology, 654 Cherry St, Atlanta, GA 30332-0535
e-mail: ajit.yoganathan{at}bme.gatech.edu
Background. Understanding the total cavopulmonary connection (TCPC) hemodynamics may lead to improved surgical procedures which result in a more efficient modified circulation. Reduced energy loss will translate to less work for the single ventricle and although univentricular physiology is complex, this improvement could contribute to improved postoperative outcomes. Therefore to conserve energy, one surgical goal is optimization of the TCPC geometry. In line with this goal, this study investigated whether addition of caval curvature or flaring at the connection conserves energy.
Methods. TCPC models were made varying the curvature of the caval inlet or by flaring the anastomosis. Steady flow pressure measurements were made to calculate the power loss attributed to each connection design over a range of pulmonary flow splits (70:30 to 30:70). Particle flow visualization was performed for each design and was qualitatively compared to the power losses.
Results. Results indicate that curving the cavae toward one pulmonary artery is advantageous only when the flow rate from that cavae matches the flow to the pulmonary artery. Under other pulmonary flow split conditions, the losses in the curved models are significant. In contrast, fully flaring the anastomosis reduced losses over the range of pulmonary flow splits. Power losses were 56% greater for the curving as compared to flaring. Fully flaring without caval offset reduced losses 45% when compared to previous models without flaring. If flaring on all sides was implemented with caval offset, power losses reduced 68% compared to the same nonflared model.
Conclusions. The results indicate that preferentially curving the cavae is only optimal under specific pulmonary flow conditions and may not be efficient in all clinical cases. Flaring of the anastomosis has great potential to conserve energy and should be considered in future TCPC procedures.
This article has been cited by other articles:
![]() |
L. P. Dasi, R. KrishnankuttyRema, H. D. Kitajima, K. Pekkan, K. S. Sundareswaran, M. Fogel, S. Sharma, K. Whitehead, K. Kanter, and A. P. Yoganathan Fontan hemodynamics: importance of pulmonary artery diameter. J. Thorac. Cardiovasc. Surg., March 1, 2009; 137(3): 560 - 564. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. S. Sundareswaran, K. Pekkan, L. P. Dasi, K. Whitehead, S. Sharma, K. R. Kanter, M. A. Fogel, and A. P. Yoganathan The total cavopulmonary connection resistance: a significant impact on single ventricle hemodynamics at rest and exercise Am J Physiol Heart Circ Physiol, December 1, 2008; 295(6): H2427 - H2435. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. KrishnankuttyRema, L. P. Dasi, K. Pekkan, K. Sundareswaran, M. Fogel, S. Sharma, K. Kanter, T. Spray, and A. P. Yoganathan Quantitative Analysis of Extracardiac Versus Intraatrial Fontan Anatomic Geometries Ann. Thorac. Surg., March 1, 2008; 85(3): 810 - 817. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. D. Soerensen, K. Pekkan, D. de Zelicourt, S. Sharma, K. Kanter, M. Fogel, and A. P. Yoganathan Introduction of a New Optimized Total Cavopulmonary Connection Ann. Thorac. Surg., June 1, 2007; 83(6): 2182 - 2190. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Murakami, N. Yoshimura, J. Kitahara, S. Otaka, F. Ichida, and T. Misaki Collision of the caval flows caused early failure of the Fontan circulation. J. Thorac. Cardiovasc. Surg., November 1, 2006; 132(5): 1235 - 1236. [Full Text] [PDF] |
||||
![]() |
K. S. Sundareswaran, K. R. Kanter, H. D. Kitajima, R. Krishnankutty, J. F. Sabatier, W. J. Parks, S. Sharma, A. P. Yoganathan, and M. Fogel Impaired power output and cardiac index with hypoplastic left heart syndrome: a magnetic resonance imaging study. Ann. Thorac. Surg., October 1, 2006; 82(4): 1267 - 1277. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. Pekkan, H. D. Kitajima, D. de Zelicourt, J. M. Forbess, W. J. Parks, M. A. Fogel, S. Sharma, K. R. Kanter, D. Frakes, and A. P. Yoganathan Total Cavopulmonary Connection Flow With Functional Left Pulmonary Artery Stenosis: Angioplasty and Fenestration In Vitro Circulation, November 22, 2005; 112(21): 3264 - 3271. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. A. de Zelicourt, K. Pekkan, L. Wills, K. Kanter, J. Forbess, S. Sharma, M. Fogel, and A. P. Yoganathan In Vitro Flow Analysis of a Patient-Specific Intraatrial Total Cavopulmonary Connection Ann. Thorac. Surg., June 1, 2005; 79(6): 2094 - 2102. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. L. Bove, M. R. de Leval, F. Migliavacca, G. Guadagni, and G. Dubini Computational fluid dynamics in the evaluation of hemodynamic performance of cavopulmonary connections after the norwood procedure for hypoplastic left heart syndrome J. Thorac. Cardiovasc. Surg., October 1, 2003; 126(4): 1040 - 1047. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Amodeo, M. Grigioni, G. Oppido, C. Daniele, G. D'Avenio, G. Pedrizzetti, S. Giannico, S. Filippelli, and R. M. Di Donato The beneficial vortex and best spatial arrangement in total extracardiac cavopulmonary connection J. Thorac. Cardiovasc. Surg., September 1, 2002; 124(3): 471 - 478. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Senzaki, S. Masutani, J. Kobayashi, T. Kobayashi, N. Sasaki, H. Asano, S. Kyo, Y. Yokote, and A. Ishizawa Ventricular Afterload and Ventricular Work in Fontan Circulation: Comparison With Normal Two-Ventricle Circulation and Single-Ventricle Circulation With Blalock-Taussig Shunts Circulation, June 18, 2002; 105(24): 2885 - 2892. [Abstract] [Full Text] [PDF] |
||||
![]() |
E M Pedersen, E V Stenbog, T Frund, K Houlind, O Kromann, K E Sorensen, K Emmertsen, and V E Hjortdal Flow during exercise in the total cavopulmonary connection measured by magnetic resonance velocity mapping Heart, June 1, 2002; 87(6): 554 - 558. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Sharma, A. E. Ensley, K. Hopkins, G. P. Chatzimavroudis, T. M. Healy, V. K.H. Tam, K. R. Kanter, and A. P. Yoganathan In vivo flow dynamics of the total cavopulmonary connection from three-dimensional multislice magnetic resonance imaging Ann. Thorac. Surg., March 1, 2001; 71(3): 889 - 898. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. G. Walker, T. T. Howe, R. L. Davies, J. Fisher, and K. G. Watterson Distribution of hepatic venous blood in the total cavo-pulmonary connection: an in vitro study Eur. J. Cardiothorac. Surg., June 1, 2000; 17(6): 658 - 665. [Abstract] [Full Text] [PDF] |
||||