ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Edward B. Savage
Richard E. Clark
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Savage, E. B.
Right arrow Articles by Magovern, G. J.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Savage, E. B.
Right arrow Articles by Magovern, G. J., Sr

Ann Thorac Surg 1999;68:768-774
© 1999 The Society of Thoracic Surgeons


Innovative Circulatory Support Systems

The AB-180 circulatory support system: summary of development and plans for phase I clinical trial

Edward B. Savage, MDa, Richard E. Clark, MDa, Wayne P. Griffin, MSa, Scott A. Davisa, Suzanne Hughson, MSa, Christopher J. Conway, MSa, George J. Magovern, Sr, MDa

a Allegheny General Hospital, Allegheny-Singer Research Institute, Pittsburgh, Pennsylvania, USA

Address reprint requests to Dr Savage, Department of Cardiothoracic-Vascular Surgery, Rush University, Suite 1156, 1725 West Harrison St, Chicago, IL 60612

Presented at the Fourth International Conference on Circulatory Support Devices for Severe Cardiac Failure, Houston, TX, Oct 3–5, 1997.

Abstract

Background. The AB-180 circulatory support system is a small, durable, efficient centrifugal pump with low thrombogenic potential. The device was designed to provide a fully implantable, left ventricular assist system for short-term support to address the issues of systemic anticoagulation, thrombus formation, infection, and cost.

Methods. Extensive bench and animal studies were performed to validate the mechanical integrity of the device and its functionality as an implant.

Results. These studies demonstrated anticoagulation requirements, established operating guidelines, incorporated safety systems, and demonstrated safety and efficacy.

Conclusions. The AB-180 fulfills the stated goals on initial evaluation. A phase I human trial is underway.




This article has been cited by other articles:


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. J. Endo, K. Kojima, K. Nakamura, Y. Matsuzaki, and T. Onitsuka
Nitric oxide inhalation prompts weaning from the right ventricular assist device: Evaluation under continuous-flow biventricular assistance
J. Thorac. Cardiovasc. Surg., October 1, 2002; 124(4): 739 - 749.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
B. W. Duncan
Mechanical circulatory support for infants and children with cardiac disease
Ann. Thorac. Surg., May 1, 2002; 73(5): 1670 - 1677.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. A. Magovern, M. J. Sussman, A. H. Goldstein, G. W. Szydlowski, E. B. Savage, and S. Westaby
Clinical results with the AB-180 left ventricular assist device
Ann. Thorac. Surg., March 1, 2001; 71 (2007): S121 - S124.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1999 by The Society of Thoracic Surgeons.