ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Gregory S. Couper
David H. Adams
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Couper, G. S.
Right arrow Articles by Adams, D. H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Couper, G. S.
Right arrow Articles by Adams, D. H.

Ann Thorac Surg 1999;68:646-649
© 1999 The Society of Thoracic Surgeons


Economics of a Clinical Device Program

The logistics and cost-effectiveness of circulatory support: advantages of the ABIOMED BVS 5000

Gregory S. Couper, MDa, Rene J. Dekkers, CCPa, David H. Adams, MDa

a Division of Cardiac Surgery, Brigham and Women’s Hospital, Harvard Medical School, Boston, Massachusetts, USA

Address reprint requests to Dr. Couper, Division of Cardiac Surgery, Brigham and Women’s Hospital, 75 Francis St, Boston, MA 02115

Presented at the Fourth International Conference on Circulatory Support Devices for Severe Cardiac Failure, Houston, TX, Oct 3–5, 1997.

Abstract

Background. In 1994, the ABIOMED BVS 5000 was incorporated into our acute cardiac assist armamentarium. This report is a general overview of our experience. A hypothetical cost analysis focusing on specific devices and device-related personnel contrasted the BVS 5000 with our prior model of centrifugal pump use.

Methods. In 3 years, 22 patients were supported with the BVS 5000, as a biventricular assist device in 40%, right ventricular assist device in 27%, and left ventricular assist device in 32%. Indications were postcardiotomy support in 12, acute myocarditis in 2, bridge to transplant in 4, and failed heart transplant in 4. The cost analysis was performed retrospectively. The actual cost of disposable blood pumps, including replacement pumps, and cannulae constituted the BVS cost. The hypothetical centrifugal costs included the disposables, replacement cones, as well as the labor costs of the continuous perfusionist coverage.

Results. Of the 22 patients, 10 (45%) were weaned and 13 (59%) were successfully discharged. Five patients were transplanted while on BVS 5000 support, accounting for a higher rate of discharge. Comparison of "actual" BVS costs with "projected" centrifugal costs revealed differences based upon the intended application of the BVS. In bridge-to-transplant patients with long duration of support, the daily cost of support was dramatically lower with the BVS 5000. For short-term postcardiotomy support, acute myocarditis, or failed transplant, the differences were small.

Conclusions. Because the BVS 5000 was readily managed by the intensive care unit nursing staff, this system displaced centrifugal systems in our program. Outcome measures of weaning and successful discharge were improved relative to our prior experience with centrifugal pumps. Even without taking indirect costs into account, the hypothetical cost analysis supported continued use of the BVS system for acute cardiac assistance.




This article has been cited by other articles:


Home page
Card Surg AdultHome page
S. Aggarwal, F. Cheema, M. C. Oz, and Y. Naka
Long-Term Mechanical Circulatory Support
Card. Surg. Adult, January 1, 2008; 3(2008): 1609 - 1628.
[Full Text]


Home page
CirculationHome page
A. F. Hernandez, J. D. Grab, J. S. Gammie, S. M. O'Brien, B. G. Hammill, J. G. Rogers, M. T. Camacho, M. K. Dullum, T. B. Ferguson, and E. D. Peterson
A Decade of Short-Term Outcomes in Post Cardiac Surgery Ventricular Assist Device Implantation: Data From the Society of Thoracic Surgeons' National Cardiac Database
Circulation, August 7, 2007; 116(6): 606 - 612.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. John, K. Liao, K. Lietz, F. Kamdar, M. Colvin-Adams, A. Boyle, L. Miller, and L. Joyce
Experience with the Levitronix CentriMag circulatory support system as a bridge to decision in patients with refractory acute cardiogenic shock and multisystem organ failure
J. Thorac. Cardiovasc. Surg., August 1, 2007; 134(2): 351 - 358.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Tatewaki, M. Masuda, T. Nishida, Y. Kaji, H. Ushinohama, S. Morita, and H. Yasui
Successful Treatment of Tachycardia-Induced Cardiomyopathy With LVAD in a 12-Year-Old Boy
Ann. Thorac. Surg., August 1, 2005; 80(2): e5 - e7.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1999 by The Society of Thoracic Surgeons.