ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Olaf Elert
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Reents, W.
Right arrow Articles by Elert, O.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Reents, W.
Right arrow Articles by Elert, O.

Ann Thorac Surg 1999;68:58-62
© 1999 The Society of Thoracic Surgeons


Original Articles

Influence of different autotransfusion devices on the quality of salvaged blood

Wilko Reents, MDa, Jörg Babin-Ebell, MDa, Martina R. Misopha, Andreas Schwarzkopf, MDb, Olaf Elert, MDa

a Department of Cardiothoracic Surgery, University Hospital, Würzburg, Germany
b Department of Microbiology, University Hospital, Würzburg, Germany

Address reprint requests to Dr Reents, Klinik und Poliklinik für Herz- und Thoraxchirurgie, Josef-Schneider-Str 6, D-97080 Würzburg, Germany

Background. Cardiopulmonary bypass causes a systemic inflammatory response and impaired hemostasis. We investigated whether intraoperative blood salvage with the cardiotomy suction contributes to these alterations. Furthermore, an alternative autotransfusion device (Haemonetics cell-saving device) was examined.

Methods. In 10 patients, interleukin-6, interleukin-8, tumor necrosis factor-{alpha}, thrombin-antithrombin complex, plasmin-antiplasmin complex, free hemoglobin, and the percentage of CD62+ thrombocytes were determined in the systemic circulation during cardiopulmonary bypass, in the cardiotomy suction tube, and in the blood from the cell-saving device. Additionaly, bacterial contamination was examined.

Results. Median levels of interleukin-6 (52 versus 10 µg/L; p = 0.005), interleukin-8 (26 versus 20 µg/L; p = 0.017), tumor necrosis factor-{alpha} (24 versus 1 µg/L; p = 0.005), thrombin-antithrombin complex (113 versus 43 µg/L; p = 0.005), plasmin-antiplasmin complex (566 versus 489 µg/L; p = 0.022), and free hemoglobin (61 versus 30 mg/dL; p = 0.005) were higher in the cardiotomy suction tube compared with the systemic circulation. After processing the blood from the cell-saving device, interleukin-8, thrombin-antithrombin complex, and free hemoglobin remained above reference range, and in 90% of the cases bacterial contamination was observed.

Conclusions. Cardiotomy suction additionally contributes to the release of proinflammatory cytokines, activation of coagulation, and hemolysis. Because blood salvage with a Haemonetics cell-saving device led to normalization of some, but not all, parameters and bacterial contamination was common, the alternative use seems at least questionable.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
The Society of Thoracic Surgeons Blood Conservatio, V. A. Ferraris, S. P. Ferraris, S. P. Saha, E. A. Hessel II, C. K. Haan, B. D. Royston, C. R. Bridges, R. S.D. Higgins, G. Despotis, et al.
Perioperative Blood Transfusion and Blood Conservation in Cardiac Surgery: The Society of Thoracic Surgeons and The Society of Cardiovascular Anesthesiologists Clinical Practice Guideline
Ann. Thorac. Surg., May 1, 2007; 83(5_Supplement): S27 - S86.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
S. J. Allen, W. T. McBride, T. J. McMurray, A. S. Phillips, S. P. Penugonda, G. Campalani, I. S. Young, and M. A. Armstrong
Cell Salvage Alters the Systemic Inflammatory Response After Off-Pump Coronary Artery Bypass Grafting Surgery
Ann. Thorac. Surg., February 1, 2007; 83(2): 578 - 585.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
G. Niranjan, G. Asimakopoulos, A. Karagounis, G. Cockerill, M. Thompson, and V. Chandrasekaran
Effects of cell saver autologous blood transfusion on blood loss and homologous blood transfusion requirements in patients undergoing cardiac surgery on- versus off-cardiopulmonary bypass: a randomised trial.
Eur. J. Cardiothorac. Surg., August 1, 2006; 30(2): 271 - 277.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
M. Westerberg, J. Gabel, A. Bengtsson, J. Sellgren, O. Eidem, and A. Jeppsson
Hemodynamic effects of cardiotomy suction blood
J. Thorac. Cardiovasc. Surg., June 1, 2006; 131(6): 1352 - 1357.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
M J ten Brinke, P W Weerwind, S Teerenstra, J C. Feron, W van der Meer, and M H. Brouwer
Leukocyte removal efficiency of cell-washed and unwashed whole blood: an in vitro study
Perfusion, December 1, 2005; 20(6): 335 - 341.
[Abstract] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G.J. Murphy, C.S. Rogers, W.B. Lansdowne, I. Channon, H. Alwair, A. Cohen, M. Caputo, and G.D. Angelini
Safety, efficacy, and cost of intraoperative cell salvage and autotransfusion after off-pump coronary artery bypass surgery: A randomized trial
J. Thorac. Cardiovasc. Surg., July 1, 2005; 130(1): 20 - 28.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J. Wippermann, J. M. Albes, M. Hartrumpf, M. Kaluza, R. Vollandt, R. Bruhin, and T. Wahlers
Comparison of minimally invasive closed circuit extracorporeal circulation with conventional cardiopulmonary bypass and with off-pump technique in CABG patients: selected parameters of coagulation and inflammatory system
Eur. J. Cardiothorac. Surg., July 1, 2005; 28(1): 127 - 132.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Westerberg, A. Bengtsson, and A. Jeppsson
Coronary surgery without cardiotomy suction and autotransfusion reduces the postoperative systemic inflammatory response
Ann. Thorac. Surg., July 1, 2004; 78(1): 54 - 59.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. J. de Vries, Y. J. Gu, Y. L. Douglas, W. J. Post, H. Lip, and W. van Oeveren
Clinical evaluation of a new fat removal filter during cardiac surgery
Eur. J. Cardiothorac. Surg., February 1, 2004; 25(2): 261 - 266.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
P. Biglioli, A. Cannata, F. Alamanni, M. Naliato, M. Porqueddu, M. Zanobini, E. Tremoli, and A. Parolari
Biological effects of off-pump vs. on-pump coronary artery surgery: focus on inflammation, hemostasis and oxidative stress
Eur. J. Cardiothorac. Surg., August 1, 2003; 24(2): 260 - 269.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. E. Jewell, E. F. Akowuah, S. K. Suvarna, P. Braidley, D. Hopkinson, and G. Cooper
A prospective randomised comparison of cardiotomy suction and cell saver for recycling shed blood during cardiac surgery
Eur. J. Cardiothorac. Surg., April 1, 2003; 23(4): 633 - 636.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
G. S. Aldea, L. O. Soltow, W. L. Chandler, C. M. Triggs, C. R. Vocelka, G. I. Crockett, Y. T. Shin, W. E. Curtis, and E. D. Verrier
Limitation of thrombin generation, platelet activation, and inflammation by elimination of cardiotomy suction in patients undergoing coronary artery bypass grafting treated with heparin-bonded circuits
J. Thorac. Cardiovasc. Surg., April 1, 2002; 123(4): 742 - 755.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
T Amand, J Pincemail, F Blaffart, R Larbuisson, R Limet, and J O Defraigne
Levels of inflammatory markers in the blood processed by autotransfusion devices during cardiac surgery associated with cardiopulmonary bypass circuit
Perfusion, March 1, 2002; 17(2): 117 - 123.
[Abstract] [PDF]


Home page
PerfusionHome page
M H Cross
Autotransfusion in cardiac surgery
Perfusion, September 1, 2001; 16(5): 391 - 400.
[Abstract] [PDF]


Home page
Ann. Thorac. Surg.Home page
N. Tabuchi, M. Sunamori, T. Koyama, and A. Shibamiya
Remaining procoagulant property of wound blood washed by a cell-saving device
Ann. Thorac. Surg., May 1, 2001; 71(5): 1749 - 1749.
[Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
W. Reents, J. Babin-Ebell, and O. Elert
Remaining procoagulant property of wound blood washed by a cell-saving device: Reply
Ann. Thorac. Surg., May 1, 2001; 71(5): 1749 - 1750.
[Full Text] [PDF]


Home page
PerfusionHome page
J W Mulholland, W Massey, and J C Shelton
Investigation and quantification of the blood trauma caused by the combined dynamic forces experienced during cardiopulmonary bypass
Perfusion, December 1, 2000; 15(6): 485 - 494.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1999 by The Society of Thoracic Surgeons.