Ann Thorac Surg 1999;67:1802-1803
© 1999 The Society of Thoracic Surgeons
a Department of Cardiac Surgery, Hospital de Navarra, Pamplona, Spain
Accepted for publication November 18, 1998.
Address reprint requests to Dr de la Fuente, Department of Cardiac Surgery, Hospital de Navarra, C/Irunlarrea no. 3, 31008 Pamplona, Spain
e-mail: anselmo.delafuente.calixto{at}cfnavarra.es
Rupture of the left ventricular wall is an infrequent but lethal complication after mitral valve replacement. We present the case of a patient in whom such a rupture was successfully repaired in the intensive care unit with a patch of Teflon felt stuck in place with glue.
This article has been cited by other articles:
![]() |
H. Deniz, O. Sokullu, S. Sanioglu, M. Sargin, B. Ozay, U. Ayoglu, S. Aykut Aka, and F. Bilgen Risk factors for posterior ventricular rupture after mitral valve replacement: results of 2560 patients Eur. J. Cardiothorac. Surg., October 1, 2008; 34(4): 780 - 784. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. Masroor, J. Schor, R. Carrillo, and D. B. Williams Endoventricular pocket repair of type I myocardial rupture after mitral valve replacement: a new technique using pericardial patch, Teflon felt, and BioGlue Ann. Thorac. Surg., April 1, 2004; 77(4): 1439 - 1441. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Fasol, T. Wild, and S. El Dsoki Left ventricular rupture after mitral surgery: repair by patch and sealing Ann. Thorac. Surg., March 1, 2004; 77(3): 1070 - 1072. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Kaplan, S. Bozkurt, M. S. Kut, S. Kullu, and M. M. Demirtas Histopathological effects of ethyl 2-cyanoacrylate tissue adhesive following surgical application: an experimental study Eur. J. Cardiothorac. Surg., February 1, 2004; 25(2): 167 - 172. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |