Ann Thorac Surg 1999;67:1760-1764
© 1999 The Society of Thoracic Surgeons
a Department of Cardiac Surgery, Medical University of Lübeck, Lübeck, Germany
b Institute of Applied Physics, Christian-Albrechts-University of Kiel, Kiel, Germany
Accepted for publication December 21, 1998.
Address reprint requests to Dr Sievers, Klinik für Herzchirurgie, Medizinische Universität zu Lübeck, Ratzeburger Allee 160, D-23538 Lübeck, Germany
Background. In the Fontan circulation the vis a tergo for lung perfusion is limited. The hypothesis of this in vitro study was that energy dissipation at the common cavopulmonary connection can be reduced by the addition of caval curvature.
Methods. Two Perspex models were analyzed, the commonly used crosslike cavopulmonary connection (model 1) and a modified curved configuration (model 2). Pressures and flows across the connections were measured simultaneously at various caval and pulmonary artery flow splits and resistances. Mixing of inferior and superior caval fluid was evaluated.
Results. Caval pressure oscillations occurred in model 1 only. Curvature reduced power losses in all settings significantly (
= 0.05), most successfully at adult caval flow ratios and at high flow rates. At equal pulmonary resistances pulmonary flow was balanced in both models. The inferior caval fluid is preferably directed to the right lung in model 2 predominantly for caval flow conditions in younger patients.
Conclusions. Our data show that the modified curved cavopulmonary connection is hydrodynamically advantageous but might impair caval fluid mixing in younger children.
This article has been cited by other articles:
![]() |
A. L. Marsden, A. J. Bernstein, V. M. Reddy, S. C. Shadden, R. L. Spilker, F. P. Chan, C. A. Taylor, and J. A. Feinstein Evaluation of a novel Y-shaped extracardiac Fontan baffle using computational fluid dynamics. J. Thorac. Cardiovasc. Surg., February 1, 2009; 137(2): 394 - 403.e2. [Abstract] [Full Text] [PDF] |
||||
![]() |
E. L. Bove, M. R. de Leval, F. Migliavacca, G. Guadagni, and G. Dubini Computational fluid dynamics in the evaluation of hemodynamic performance of cavopulmonary connections after the norwood procedure for hypoplastic left heart syndrome J. Thorac. Cardiovasc. Surg., October 1, 2003; 126(4): 1040 - 1047. [Abstract] [Full Text] [PDF] |
||||