ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Shigefumi Suehiro
Toshihiko Shibata
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Kumano, H.
Right arrow Articles by Kinoshita, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Kumano, H.
Right arrow Articles by Kinoshita, H.

Ann Thorac Surg 1999;67:1484-1485
© 1999 The Society of Thoracic Surgeons


Case Reports

Stuck valve leaflet detected by intraoperative transesophageal echocardiography

Hiroshi Kumano, MDa, Shigefumi Suehiro, MD, PhDa, Toshihiko Shibata, MDa, Koji Hattori, MD, PhDb, Hiroaki Kinoshita, MD, PhDa

a Second Department of Surgery, Osaka City University Medical School, Osaka, Japan
b Division of Cardiovascular Surgery, Osaka City General Hospital, Osaka, Japan

Accepted for publication October 26, 1998.

Address reprint requests to Dr Kumano, Second Department of Surgery, Osaka City University Medical School, 1-5-7, Asahimachi, Abeno-ku, Osaka 545-0051, Japan

We encountered a rare complication of mitral valve replacement with the CarboMedics prosthesis: a "stuck" leaflet detected by transesophageal echocardiography even though weaning from cardiopulmonary bypass had been uneventful. The patient was immediately managed without significant problems. We emphasize the importance of performing routine intraoperative transesophageal echocardiography in valve replacement as well as in valve repair, from the initial phase of operation.




This article has been cited by other articles:


Home page
Card Surg AdultHome page
M. Enriquez-Sarano, V. T. Nkomo, and H. Michelena
Principles and Practice of Echocardiography in Cardiac Surgery
Card. Surg. Adult, January 1, 2008; 3(2008): 315 - 348.
[Full Text]


Home page
ICVTSHome page
J. Almeida, A. Santos, F. Barreiros, M. Garcia, and P. Pinho
Stuck leaflet of bileaflet prosthesis in mitral position - five cases to make us think
Interactive CardioVascular and Thoracic Surgery, June 1, 2007; 6(3): 379 - 383.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Shapira, M. Vaturi, D. E. Weisenberg, E. Raanani, G. Sahar, E. Snir, A. Battler, B. A. Vidne, and A. Sagie
Impact of intraoperative transesophageal echocardiography in patients undergoing valve replacement
Ann. Thorac. Surg., August 1, 2004; 78(2): 579 - 583.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. Fukui, S. Suehiro, T. Shibata, K. Hattori, and H. Hirai
Retropericardial hematoma complicating off-pump coronary artery bypass surgery
Ann. Thorac. Surg., May 1, 2002; 73(5): 1629 - 1631.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1999 by The Society of Thoracic Surgeons.