|
|
||||||||
Ann Thorac Surg 1999;67:645-651
© 1999 The Society of Thoracic Surgeons
a Department of Surgery, Rikshospitalet, Oslo, Norway
Accepted for publication July 31, 1998.
Address reprint requests to Dr Arafa, Department of Surgery A, Rikshospitalet, 0027 Oslo, Norway
Background. The beneficial effects of the intraaortic balloon pump (IABP) in providing circulatory support must be weighed against its complications, particularly its vascular trauma.
Methods. Five hundred nine patients who underwent open heart operations at our institution and who were treated with the IABP from January 1980 through December 1994 were studied retrospectively to assess IABP-related vascular complications and their independent preoperative predictors and the implications of IABP-related vascular complications on the patients mortality, morbidity (clinical sepsis and organ failure), and long-term survival.
Results. Early vascular complications occurred in 56 patients (11%) and major complications occurred in 41 patients (8%). The latter consisted of aortic perforation in 1 patient, aortoiliac dissection in 2 patients, and limb ischemia in 38 patients. Logistic regression analysis identified concomitant peripheral vascular disease (p < 0.001), elevated preoperative end-diastolic pressure, small body surface area, and large catheter size (p < 0.05) as independent risk factors for IABP-related major vascular complications in patients who survived the day of operation. Late IABP-related sequelae occurred in 10 patients, 9 of whom had had early vascular complications. The presence of vascular complications per se was not a significant independent factor among other risk factors for mortality, morbidity, or long-term survival.
Conclusions. Careful clinical assessment of the aortofemoral vascular tree is a cornerstone of early diagnosis and early intervention and usually prevents limb loss. The significant decrease in major vascular complications that has occurred over the last 5 years can be explained by the increased use of catheters with smaller diameters. The timing of IABP insertion in relation to operation and the duration of IABP use were the only device-related risk factors identified for morbidity and survival.
This article has been cited by other articles:
![]() |
G. Zattera, P. Totaro, A. M. D'Armini, and M. Vigano Intra aortic balloon pump insertion through left axillary artery in patients with severe peripheral arterial disease Interactive CardioVascular and Thoracic Surgery, August 1, 2009; 9(2): 369 - 370. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Gjesdal, E. Gude, S. Arora, T. Leivestad, A. K. Andreassen, L. Gullestad, L. Aaberge, H. Brunvand, T. Edvardsen, O. R. Geiran, et al. Intra-aortic balloon counterpulsation as a bridge to heart transplantation does not impair long-term survival Eur J Heart Fail, July 1, 2009; 11(7): 709 - 714. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Karimi, N. Movahedi, A. Salehiomran, M. Marzban, S. Hesameddin Abbasi, and P. Yazdanifard Mortality in Open Heart Surgery with Intraaortic Balloon Pump Support Asian Cardiovasc Thorac Ann, August 1, 2008; 16(4): 301 - 304. [Abstract] [Full Text] [PDF] |
||||
![]() |
I. R. Ramnarine, A. D. Grayson, W. C. Dihmis, N. K. Mediratta, B. M. Fabri, and J. A.C. Chalmers Timing of intra-aortic balloon pump support and 1-year survival Eur. J. Cardiothorac. Surg., May 1, 2005; 27(5): 887 - 892. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. E. Muhs, A. C. Galloway, M. Lombino, M. Silberstein, E. A. Grossi, S. B. Colvin, P. Lamparello, G. Jacobowitz, M. A. Adelman, C. Rockman, et al. Arterial Injuries from Femoral Artery Cannulation with Port Access Cardiac Surgery Vascular and Endovascular Surgery, March 1, 2005; 39(2): 153 - 158. [Abstract] [PDF] |
||||
![]() |
J. Mand'ak, V. Lonsky, J. Dominik, and P. Zacek Vascular Complications of the Intra-aortic Balloon Counterpulsation Angiology, January 1, 2005; 56(1): 69 - 74. [Abstract] [PDF] |
||||
![]() |
A. Arceo, P. Urban, P.-A. Dorsaz, P. Chatelain, V. Verin, C. Suilen, E. Rombaut, and J.-C. Chevrolet In-Hospital Complications of Percutaneous Intraaortic Balloon Counterpulsation Angiology, September 1, 2003; 54(5): 577 - 585. [Abstract] [PDF] |
||||
![]() |
G. W. Stone, E. M. Ohman, M. F. Miller, D. L. Joseph, J. T. Christenson, M. Cohen, P. M. Urban, R. C. Reddy, R. J. Freedman, K. L. Staman, et al. Contemporary utilization and outcomes of intra-aortic balloon counterpulsation in acute myocardial infarction: The benchmark registry J. Am. Coll. Cardiol., June 4, 2003; 41(11): 1940 - 1945. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Pandey, G. Ciotti, and M. Pozzi Anomalous origin of the left coronary artery from the pulmonary artery: results of surgical correction in five infants Ann. Thorac. Surg., November 1, 2002; 74(5): 1625 - 1630. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. T. Christenson, M. Cohen, J. J. Ferguson III, R. J. Freedman, M. F. Miller, E. M. Ohman, R. C. Reddy, G. W. Stone, and P. M. Urban Trends in intraaortic balloon counterpulsation complications and outcomes in cardiac surgery Ann. Thorac. Surg., October 1, 2002; 74(4): 1086 - 1090. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Naughton and C. A. Bashour Mechanical Support After Cardiac Surgery Seminars in Cardiothoracic and Vascular Anesthesia, September 1, 2002; 6(3): 237 - 257. [Abstract] [PDF] |
||||
![]() |
Z.S. Meharwal and N. Trehan Reply to Totaro et al. Eur. J. Cardiothorac. Surg., September 1, 2002; 22(3): 492 - 493. [Full Text] [PDF] |
||||
![]() |
Z. S. Meharwal and N. Trehan Vascular complications of intra-aortic balloon insertion in patients undergoing coronary reavscularization: analysis of 911 cases Eur. J. Cardiothorac. Surg., April 1, 2002; 21(4): 741 - 747. [Abstract] [Full Text] [PDF] |
||||
![]() |
V. Bautista-Hernandez, J. Moya, J. Martinell, M. L. Polo, and J. Fraile Successful stent-grafting for perforation of the thoracic aorta by an intraaortic balloon pump Ann. Thorac. Surg., March 1, 2002; 73(3): 956 - 958. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. J. Ferguson III, M. Cohen, R. J. Freedman Jr, G. W. Stone, M. F. Miller, D. L. Joseph, and E. M. Ohman The current practice of intra-aortic balloon counterpulsation: results from the Benchmark Registry J. Am. Coll. Cardiol., November 1, 2001; 38(5): 1456 - 1462. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. P. Meyns, Y. Nishimura, R. Jashari, R. Racz, V. H. Leunens, and W. J. Flameng Ascending versus descending aortic balloon: Pumping: organ and myocardial perfusion during ischemia Ann. Thorac. Surg., October 1, 2000; 70(4): 1264 - 1269. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. T. Christenson, F. Simonet, and M. Schmuziger Economic impact of preoperative intraaortic balloon pump therapy in high-risk coronary patients Ann. Thorac. Surg., August 1, 2000; 70(2): 510 - 515. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Shin, R. Yozu, T. Sumida, and S. Kawada Acute ischemic hepatic failure resulting from intraaortic balloon pump malposition Eur. J. Cardiothorac. Surg., April 1, 2000; 17(4): 492 - 494. [Abstract] [Full Text] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |