ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Urban Lönn
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Lönn, U.
Right arrow Articles by Casimir-Ahn, H.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Lönn, U.
Right arrow Articles by Casimir-Ahn, H.
Related Collections
Right arrowRelated Article

Ann Thorac Surg 1999;67:99-104
© 1999 The Society of Thoracic Surgeons


Original Articles

Beating heart coronary surgery supported by an axial blood flow pump

Urban Lönn, MD, PhDa, Bengt Peterzén, MDa, Bo Carnstam, CCPa, Henrik Casimir-Ahn, MD, PhDa

a Linköping Heart Center, University Hospital, Linköping, Sweden

Accepted for publication July 1, 1998.

Address reprint requests to Dr Lönn, Linköping Heart Center, University Hospital, 581 85 Linköping, Sweden

Background. We have previously presented a method for performing coronary artery bypass graft operation on the beating heart without cardiopulmonary bypass (CPB). This method has now been explored.

Method. Thirty-two patients were prospectively randomized. The study group was operated on using an axial blood flow pump (Hemopump; HP) as circulatory support. Operations were performed on the beating heart. The control group was operated on using CPB, aortic cross-clamping, and cardioplegic arrest.

Results. All patients went through the procedure without major complications, and were discharged from the hospital. No statistical differences were observed between the groups for time on support (HP, 60.5 minutes; CPB, 70.5 minutes) or total operating time (HP, 178 minutes; CPB, 162 minutes). The number of grafts was greater in the CPB group (HP, 1.8; range, 1 to 3; CPB, 2.5; range, 1 to 4; p = 0.03). Statistical differences were found for intraoperative bleeding (HP mean, 312 mL; CPB mean, 582 mL; p = 0.0003) and myocardial trauma as measured by postoperative troponin-T values (HP, 0.23 µg/L; CPB, 1.17 µg/L; p = 0.004).

Conclusions. Hemopump-supported coronary artery bypass graft operation has been shown to be a safe and feasible procedure with the potential benefits of reduced operative bleeding and myocardial damage without prolonging intraoperative support or total operating time.


Related Article

Enio Buffolo
Ann. Thorac. Surg. 1999 67: 104. [Extract] [Full Text] [PDF]



This article has been cited by other articles:


Home page
Card Surg AdultHome page
T. M. Dewey and M. J. Mack
Myocardial Revascularization without Cardiopulmonary Bypass
Card. Surg. Adult, January 1, 2008; 3(2008): 633 - 654.
[Full Text]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
D. Bainbridge, J. Martin, and D. Cheng
Off Pump Coronary Artery Bypass Graft Surgery Versus Conventional Coronary Artery Bypass Graft Surgery: A Systematic Review of the Literature
Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 2005; 9(1): 105 - 111.
[Abstract] [PDF]


Home page
Br J AnaesthHome page
P.-G. Chassot, P. van der Linden, M. Zaugg, X. M. Mueller, and D. R. Spahn
Off-pump coronary artery bypass surgery: physiology and anaesthetic management{dagger}
Br. J. Anaesth., March 1, 2004; 92(3): 400 - 413.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
C Gobel, A Arvand, G Rau, H Reul, B Meyns, W Flameng, R Eilers, and O Marseille
A new rotary blood pump for versatile extracorporeal circulation: the DeltaStreamTM
Perfusion, September 1, 2002; 17(5): 373 - 382.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
B. Meyns, R. Autschbach, A. Boning, W. Konertz, K. Matschke, F. Schondube, K. Wiebe, and E. Fischer
Coronary artery bypass grafting supported with intracardiac microaxial pumps versus normothermic cardiopulmonary bypass: a prospective randomized trial
Eur. J. Cardiothorac. Surg., July 1, 2002; 22(1): 112 - 117.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
X. M Mueller and L. K von Segesser
Circulatory support for OPCAB procedures
Perfusion, July 1, 2002; 17(4): 305 - 312.
[Abstract] [PDF]


Home page
PerfusionHome page
X. M Mueller, M. Augstburger, Y. Boone, and L. K von Segesser
Hemocompatibility of a coaxial pump catheter for less invasive heart surgery
Perfusion, January 1, 2002; 17(1): 3 - 7.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
A. L. Dekker, G. G. Geskes, A. A. Cramers, W. R. Dassen, J. G. Maessen, K. B. Prenger, and F. H. van der Veen
Right ventricular support for off-pump coronary artery bypass grafting studied with bi-ventricular pressure-volume loops in sheep
Eur. J. Cardiothorac. Surg., February 1, 2001; 19(2): 179 - 184.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
M. P.R. Watters, R. Ascione, I. G. Ryder, F. Ciulli, A. A. Pitsis, and G. D. Angelini
Haemodynamic changes during beating heart coronary surgery with the 'Bristol Technique'
Eur. J. Cardiothorac. Surg., January 1, 2001; 19(1): 34 - 40.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Mathison, J. R. Edgerton, J. L. Horswell, J. J. Akin, and M. J. Mack
Analysis of hemodynamic changes during beating heart surgical procedures
Ann. Thorac. Surg., October 1, 2000; 70(4): 1355 - 1360.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
M. Mathison, E. Buffolo, A. D. Jatene, F. B. Jatene, H. Reichenspurner, R. G. Matheny, H. Shennib, J. J. Akin, and M. J. Mack
Right heart circulatory support facilitates coronary artery bypass without cardiopulmonary bypass
Ann. Thorac. Surg., September 1, 2000; 70(3): 1083 - 1085.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
B. Meyns, P. Sergeant, T. Nishida, B. Perek, M. Zietkiewicz, and W. Flameng
Micropumps to support the heart during CABG
Eur. J. Cardiothorac. Surg., February 1, 2000; 17(2): 169 - 174.
[Abstract] [Full Text] [PDF]


Home page
PerfusionHome page
B Meyns, P Sergeant, T Siess, M Zietkiewicz, B Perek, Y Nishida, and W Flameng
Coronary artery bypass graft with biventricular microaxial pumps
Perfusion, July 1, 1999; 14(4): 287 - 290.
[PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1999 by The Society of Thoracic Surgeons.