ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Mohammad Bashar Izzat
Anthony P.C. Yim
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Izzat, M. B.
Right arrow Articles by Chow, L. T.C.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Izzat, M. B.
Right arrow Articles by Chow, L. T.C.

Ann Thorac Surg 1999;67:85-88
© 1999 The Society of Thoracic Surgeons


Original Articles

Favorable scanning electron microscopic findings of stapled saphenous vein–carotid artery anastomoses

Mohammad Bashar Izzat, FRCS(CTh)a, Anthony P.C. Yim, MDa, Kenny C.H. Ho, BVMa, Carmen S.Y. Chan, BHSca, David Yew, PhDb, Louis T.C. Chow, FRCPathc

a Surgery, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong
b Anatomy, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong
c Pathology, Prince of Wales Hospital, The Chinese University of Hong Kong, Shatin, Hong Kong

Accepted for publication June 17, 1998.

Address reprint requests to Dr Izzat, P.O. Box 33831, Rowda, Damascus, Syria
e-mail: izzat{at}cyberia.net.lb

Background. In the progress toward "off-pump" endoscopic coronary artery surgical procedures, new techniques for coronary artery anastomoses are being developed. One such approach is the use of nonpenetrating titanium clips. We evaluated the quality of anastomoses achieved using this technique in a porcine model of saphenous vein–carotid artery grafting using scanning electron microscopy.

Methods. Bilateral saphenous vein–carotid artery interposition grafts were implanted in 10 "white race" pigs, using the nonpenetrating clips in one side of the neck and conventional hand suturing on the opposite side. One week after operation, the grafts were harvested.

Results. All grafts were patent 7 days after operation, and 40 anastomoses underwent scanning electron microscopic study. In all samples, the luminal surfaces of both the carotid artery and vein graft were covered by a continuous layer of endothelial cells up to the anastomosis. Anastomotic sites in all clipped samples and most of the sutured anastomoses were completely endothelialized, and anastomotic clefts were indistinguishable. However, in 25% of sutured specimens, the suture material remained clearly visible inside the lumen of the vessel, and the subendothelial matrix remained exposed, with extensive fibrin, red blood cells, and platelet deposition on its surface.

Conclusions. Because the endothelial coverage consistently appeared to be complete and the subendothelial matrix was not exposed, it is likely that the risk of early anastomotic thrombosis is reduced by using the nonpenetrating titanium clips.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
O. Chavanon, L. P. Perrault, and P. Menasche
Favorable aspect of stapled anastomosis: an endothelial function study
Ann. Thorac. Surg., October 1, 1999; 68(4): 1443 - 1444.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1999 by The Society of Thoracic Surgeons.