Ann Thorac Surg 1998;66:2121-2122
© 1998 The Society of Thoracic Surgeons
a Department of Cardiovascular Surgery, Yamagata Prefectural Central Hospital, Yamagata, Japan
Accepted for publication June 22, 1998.
Address reprint requests to Dr Yaginuma, Department of Cardiovascular Surgery, Yamagata Prefectural Central Hospital, Sakura-cho 7-17, Yamagata city, Yamagata, 990-8520, Japan
We have developed a procedure for total aortic arch replacement using three separate Hemashield grafts and establishing deep hypothermic circulatory arrest and continuous retrograde cerebral perfusion followed by antegrade cerebral perfusion. This method is technically simple and yields secure anastomoses.
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |