|
|
||||||||
Ann Thorac Surg 1998;66:1498-1506
© 1998 The Society of Thoracic Surgeons
a Department of Cardiac, Thoracic and Vascular Surgery, Deutsches Herzzentrum Berlin, Berlin, Germany
b Department of Pediatric Cardiology and Congenital Heart Disease, Deutsches Herzzentrum Berlin, Berlin, Germany
Address reprint requests to Dr Hetzer, Deutsches Herzzentrum Berlin, Augustenburger Platz 1, 13353 Berlin, Germany
e-mail: (hetzer{at}dhzb.de)
Presented at the Thirty-fourth Annual Meeting of The Society of Thoracic Surgeons, New Orleans, LA, Jan 2628, 1998.
Background. Mechanical circulatory support in intractable heart failure in children has been limited to centrifugal pumps and extracorporeal membrane oxygenation: Since 1990 small adult-size pulsatile air-driven ventricular assist devices "Berlin Heart" (VAD) and, since 1992 miniaturized pediatric VAD (12, 15, 25, 30 mL pumps), have been used in our institution. Since 1994 the blood-contacting surfaces of the device system have been heparin-coated. In this report the experiences with VAD support in 28 children are presented.
Methods. In 28 childrenages between 6 days and 16 yearsthe Berlin Heart VAD has been applied for periods of between 12 hours and 98 days (mean, 16.9 days) aiming at keeping the patient alive and allowing for recovery from shock sequelae until later transplantation or myocardial recovery. There were three groups. Group I: with primary intention of "bridge-to-transplantation" in various forms of cardiomyopathy (n = 13) or chronic stages of congenital heart disease (n = 5). Group II: "Rescue" in intractable heart failure early after corrective surgery for congenital heart disease (n = 4) or in early graft failure after a heart transplantation (n = 1). Group III: "Acute myocarditis" (n = 5) aiming at either myocardial recovery or transplantation. Twelve were brought to the operating room under cardiac massage and 25 had been on the respirator for more than 24 hours.
Results. Twelve patients died on the system from sequelae of profound shockmultiorgan failure, sepsis, loss of peripheral circulatory resistanceor from hemorrhagic complications (n = 4) or brain death (n = 1). Thirteen patients (groups I and III) were transplanted after support periods of between 3 and 98 days with 7 long-term survivors living now up to 7.5 years (mean, 4.4 years). Three patients (groups II and III) were weaned from the system with two long-term survivors (both in group III). There were no patients in group II who survived and the "rescue" indication has been discarded for VAD since 1992. Such patients are since treated by extracorporeal membrane oxygenation (ECMO) in our institution. Out of the 8 patients placed on VAD during 1996 and 1997, 7 were successfully supported until transplantation or weaning. Thirteen patients were extubated and mobilized on the system. Whereas with the earlier systems thrombi in the blood pumps were seen in 15 instances and 2 patients suffered from thromboembolic complications, no thrombotic events occurred with the heparin-coated systems.
Conclusions. After accumulating clinical experience and several technical improvements since 1990 the use of the pediatric Berlin Heart VAD has matured into a reliable and safe system to keep patients with otherwise intractable heart failure alive until complete myocardial recovery is reached or transplantation becomes feasible. Whereas heart failure early after cardiac operation is now primarily treated by ECMO, acute myocarditis appears to be a promising precondition for complete cardiac recovery during VAD support.
This article has been cited by other articles:
![]() |
S. K. Gandhi, C. B. Huddleston, D. T. Balzer, D. J. Epstein, T. A. Boschert, and C. E. Canter Biventricular Assist Devices as a Bridge to Heart Transplantation in Small Children Circulation, September 30, 2008; 118(14_suppl_1): S89 - S93. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Monagle, E. Chalmers, A. Chan, G. deVeber, F. Kirkham, P. Massicotte, and A. D. Michelson Antithrombotic Therapy in Neonates and Children: American College of Chest Physicians Evidence-Based Clinical Practice Guidelines (8th Edition) Chest, June 1, 2008; 133(6_suppl): 887S - 968S. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. L. Steenwyk, J. K. Kirklin, W. Q. Gurley, and V. G. Nielsen The Hemostatic History of a 15-Month-Old Child Implanted with a Berlin Heart Left Ventricular Assist Device Anesth. Analg., March 1, 2007; 104(3): 538 - 540. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Hetzer, E. V. Potapov, B. Stiller, Y. Weng, M. Hubler, J. Lemmer, V. Alexi-Meskishvili, M. Redlin, F. Merkle, F. Kaufmann, et al. Improvement in survival after mechanical circulatory support with pneumatic pulsatile ventricular assist devices in pediatric patients. Ann. Thorac. Surg., September 1, 2006; 82(3): 917 - 924. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. S. Sharma, S. A. Webber, V. O. Morell, S. K. Gandhi, P. D. Wearden, J. R. Buchanan, and R. L. Kormos Ventricular assist device support in children and adolescents as a bridge to heart transplantation. Ann. Thorac. Surg., September 1, 2006; 82(3): 926 - 932. [Abstract] [Full Text] [PDF] |
||||
![]() |
D. Rosenthal and D. Bernstein Pediatric Mechanical Circulatory Support: Challenges and Opportunities Circulation, May 16, 2006; 113(19): 2266 - 2268. [Full Text] [PDF] |
||||
![]() |
G. H. Dunnington Jr, J. Sleasman, A. Alkhaldi, M. P. Pelletier, B. A. Reitz, and R. C. Robbins Successful Bridge to Transplant Using the Berlin Heart Left Ventricular Assist Device in a 3-Month-Old Infant. Ann. Thorac. Surg., March 1, 2006; 81(3): 1116 - 1118. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. A. Padalino, R. G. Ohye, A. C. Chang, R. J. Gajarski, E. L. Bove, and E. J. Devaney Bridge to Transplant Using the MicroMed DeBakey Ventricular Assist Device in a Child with Idiopathic Dilated Cardiomyopathy. Ann. Thorac. Surg., March 1, 2006; 81(3): 1118 - 1121. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. T. Baldwin, H. S. Borovetz, B. W. Duncan, M. J. Gartner, R. K. Jarvik, W. J. Weiss, and T. R. Hoke The National Heart, Lung, and Blood Institute Pediatric Circulatory Support Program Circulation, January 3, 2006; 113(1): 147 - 155. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. Stiller, Y. Weng, M. Hubler, J. Lemmer, N. Nagdyman, M. Redlin, P. E. Lange, and R. Hetzer Pneumatic pulsatile ventricular assist devices in children under 1 year of age Eur. J. Cardiothorac. Surg., August 1, 2005; 28(2): 234 - 239. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Chaudhari, J. Sturman, J. O'Sullivan, J. Smith, N. Wrightson, G. Parry, D. Bolton, S. Haynes, L. Hamilton, and A. Hasan Rescue cardiac transplantation for early failure of the Fontan-type circulation in children J. Thorac. Cardiovasc. Surg., February 1, 2005; 129(2): 416 - 422. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Hetzer, Y. Weng, E. V. Potapov, M. Pasic, T. Drews, M. Jurmann, E. Hennig, and J. Muller First experiences with a novel magnetically suspended axial flow left ventricular assist device Eur. J. Cardiothorac. Surg., June 1, 2004; 25(6): 964 - 970. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. L.C. Reddy, A. Hasan, L. R.J. Hamilton, J. Dark, S. W. Schueler, D. T. Bolton, S. R. Haynes, and J. H. Smith Mechanical versus medical bridge to transplantation in children. What is the best timing for mechanical bridge? Eur. J. Cardiothorac. Surg., April 1, 2004; 25(4): 605 - 609. [Abstract] [Full Text] [PDF] |
||||
![]() |
M. Musci, M. J. Jurmann, T. Drews, C. Yankah, H. Kuppe, Y. Weng, and R. Hetzer Implantation of a left ventricular assist device in situs inversus Ann. Thorac. Surg., August 1, 2002; 74(2): 586 - 588. [Abstract] [Full Text] [PDF] |
||||
![]() |
B. W. Duncan Mechanical circulatory support for infants and children with cardiac disease Ann. Thorac. Surg., May 1, 2002; 73(5): 1670 - 1677. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. J. Hauptman, M. Jimenez-Navarro, E. Molero, E. de Teresa, R. A. Vilchez, R. Kormos, S. Kusne, B. Stiller, P. E. Lange, R. Hetzer, et al. Left Ventricular Assist Device N. Engl. J. Med., March 28, 2002; 346(13): 1023 - 1025. [Full Text] [PDF] |
||||
![]() |
C. C. Canver and J. Chanda Heart transplantation Ann. Thorac. Surg., August 1, 2001; 72(2): 658 - 660. [Full Text] [PDF] |
||||
![]() |
A. Y. Schure, P. C. Laussen, and F. X. McGowan JR Mechanical Cardiopulmonary Support of Infants and Children With Congenital Heart Disease Seminars in Cardiothoracic and Vascular Anesthesia, March 1, 2001; 5(1): 46 - 54. [Abstract] [PDF] |
||||
![]() |
R. Hetzer, J. H. Muller, Y.-g. Weng, R. Meyer, and M. Dandel Bridging-to-recovery Ann. Thorac. Surg., March 1, 2001; 71 (2007): S109 - S113. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. Hetzer, J. H. Muller, Y.-G. Weng, M. Loebe, and G. Wallukat Midterm follow-up of patients who underwent removal of a left ventricular assist device after cardiac recovery from end-stage dilated cardiomyopathy J. Thorac. Cardiovasc. Surg., November 1, 2000; 120(5): 843 - 855. [Abstract] [Full Text] [PDF] |
||||
![]() |
A K Mahmood, J M Courtney, S Westaby, M Akdis, and H Reul Critical review of current left ventricular assist devices Perfusion, September 1, 2000; 15(5): 399 - 420. [PDF] |
||||
![]() |
S. Westaby, T. Katsumata, D. Pigott, X. Y. Jin, K. Saatvedt, M. Horton, and R. E. Clark Mechanical bridge to recovery in fulminant myocarditis Ann. Thorac. Surg., July 1, 2000; 70(1): 278 - 282. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. Drews, M. Loebe, E. Hennig, F. Kaufmann, J. Muller, and R. Hetzer The 'Berlin Heart' assist device Perfusion, July 1, 2000; 15(4): 387 - 396. [PDF] |
||||
![]() |
S. Westaby HEART FAILURE: Non-transplant surgery for heart failure Heart, May 1, 2000; 83(5): 603 - 603. [Full Text] |
||||
![]() |
C. Schmitz, A. Welz, O. Dewald, R. Kozlik-Feldmann, H. Netz, and B. Reichart Switch from a BIVAD to a LVAD in a boy with Kawasaki disease Ann. Thorac. Surg., April 1, 2000; 69(4): 1270 - 1271. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. Duarte, J. F. del Canizo, and J. C. Antoranz Flexible input cannula in ventricular assist device Ann. Thorac. Surg., March 1, 2000; 69(3): 976 - 976. [Full Text] [PDF] |
||||
![]() |
S Westaby, O Franklin, and M Burch New developments in the treatment of cardiac failure Arch. Dis. Child., September 1, 1999; 81(3): 276 - 277. [Full Text] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |