ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
William R. Burfeind, Jr
Francis G. Duhaylongsod
Brian H. Annex
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Burfeind, W. R.
Right arrow Articles by Samuelson, D.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Burfeind, W. R., Jr
Right arrow Articles by Samuelson, D.

Ann Thorac Surg 1998;66:1246-1249
© 1998 The Society of Thoracic Surgeons


Original articles: cardiovascular

High-flow gas insufflation to facilitate MIDCABG: effects on coronary endothelium

William R. Burfeind, Jr, MDa, Francis G. Duhaylongsod, MDa, Brian H. Annex, MDb, David Samuelson, BAa

a Department of Surgery, Duke University Medical Center, Durham, North Carolina, USA
b Department of Medicine, Duke University Medical Center, Durham, North Carolina, USA

Accepted for publication April 24, 1998.

Address reprint requests to Dr Duhaylongsod, Duke University Medical Center, DUMC-3457, Durham, NC 27710
e-mail: (duhay001{at}mc.duke.edu)

Presented at the Seventieth Scientific Session of the American Heart Association, Orlando, FL, Nov 10–13, 1997.

Background. During less invasive coronary bypass operations on the beating heart, as well as conventional operations using continuous warm cardioplegia, a precise anastomosis is facilitated by a bloodless field. To maintain a clear field, many surgeons use high-flow gas insufflation. However, the potentially damaging effects of gas insufflation on coronary endothelium have not been elucidated.

Methods. Seven pigs underwent median sternotomy. Between two coronary occluders, an arteriotomy in the mid left anterior descending coronary artery (LAD) was performed. In the experimental group (n = 5), the operative field was kept clear by exposing the arteriotomy to a catheter-directed stream of carbon dioxide at 15 L/min. In the control group (n = 2), the arteriotomy was left open to room air. After 20 minutes, the segments of LAD exposed to carbon dioxide or room air, and the unexposed proximal LAD and right coronary artery, were processed, sectioned, and stained together. A murine anti-human tie-2 monoclonal antibody was used to identify endothelium.

Results. All unexposed LAD and right coronary artery segments and all LAD segments exposed only to room air demonstrated normal, contiguous staining of endothelium with the murine anti-human tie-2 monoclonal antibody. In contrast, all LAD segments exposed to high-flow carbon dioxide gas insufflation demonstrated near-complete loss of endothelium.

Conclusions. These data demonstrate that high-flow carbon dioxide gas insufflation denudes the coronary artery of its endothelium. This exposes blood elements to the subendothelium and promotes clotting, and endothelial loss may promote smooth muscle cell migration and proliferation. These events set the stage for early and late graft failure.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
K. M. Brown, M. M. Sabetai, and G. E. Venn
Gas embolization from the left ventricle and aortic root: A possible side effect of high-flow gas insufflation during coronary artery surgery
Ann. Thorac. Surg., July 1, 2004; 78(1): 387 - 388.
[Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
M. Capdeville and J. H. Lee
Off-Pump Coronary Artery Bypass Surgery: Revival of an Old Technique
Seminars in Cardiothoracic and Vascular Anesthesia, November 1, 2001; 5(4): 345 - 361.
[Abstract] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
Y. Okazaki, K. Takarabe, J.-i. Murayama, E. Suenaga, K. Furukawa, K. Rikitake, M. Natsuaki, and T. Itoh
Coronary endothelial damage during off-pump CABG related to coronary-clamping and gas insufflation
Eur. J. Cardiothorac. Surg., June 1, 2001; 19(6): 834 - 839.
[Abstract] [Full Text] [PDF]


Home page
Arch SurgHome page
F. G. Duhaylongsod
Minimally Invasive Cardiac Surgery Defined
Arch Surg, March 1, 2000; 135(3): 296 - 301.
[Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
H. Posacioglu, Y. Atay, T. Yagdi, T. Calkavur, M. Cikirikcioglu, S. Buket, A. Hamulu, M. Yuksel, and O. Bilkay
Simple and Cost-Effective Gas Jet for Non-Pump Coronary Bypass Surgery
Asian Cardiovasc Thorac Ann, September 1, 1999; 7(3): 250 - 251.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
L. P. Perrault, P. Menasche, and P. M. Vanhoutte
High-flow gas insufflation to facilitate MIDCAB
Ann. Thorac. Surg., March 1, 1999; 67(3): 893 - 893.
[Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1998 by The Society of Thoracic Surgeons.