ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Laman A. Gray, Jr
Paul A. Spence
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Jaber, S. F.
Right arrow Articles by Spence, P. A.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Jaber, S. F.
Right arrow Articles by Spence, P. A.

Ann Thorac Surg 1998;66:1087-1092
© 1998 The Society of Thoracic Surgeons


Supplement

Role of graft flow measurement technique in anastomotic quality assessment in minimally invasive CABG

Saad F. Jaber, MDa, Steven C. Koenig, PhDa, Bobby BhaskerRao, MDa, Daniel J. VanHimbergen, BAa, Patricia B. Cerrito, PhDa, Daniel J. Ewert, PhDa, Laman A. Gray, Jr, MDa, Paul A. Spence, MDa

a Division of Thoracic and Cardiovascular Surgery, Department of Surgery, University of Louisville, School of Medicine, Louisville, Kentucky, USA

Address reprint requests to Dr Spence, Cardiovascular Research Institute, 500 S Floyd St, Louisville, KY 40292

Presented at "Facts and Myths of Minimally Invasive Cardiac Surgery: Current Trends in Thoracic Surgery IV," New Orleans, LA, Jan 24, 1998.

Abstract

Background. Anastomotic quality is currently the critical issue in minimally invasive coronary surgery. Although little is known about its effectiveness, surgeons routinely assess grafts intraoperatively using flow probes. This study was designed to determine whether mean flow and the pattern of flow tracing in internal mammary artery grafts obtained with a transit-time flow probe are reliable indicators of anastomotic quality.

Methods. Mongrel dogs (n = 14, 30 to 35 kg) underwent off-pump left, right, or left and right internal mammary artery to left anterior descending artery anastomosis (23 grafts). Moderate to severe degrees of stenosis were created at the anastomosis by an additional suture. Internal mammary artery graft flow was measured before and after the stenosis was created with the left anterior descending artery occluded. Angiography was performed at random postoperatively to validate the degree of stenosis. Mean flow and flow tracing morphology were compared under various degrees of stenosis.

Results. There were no significant differences in mean graft flow or the morphology of the flow tracing between patent (<15%), mild (<25%), moderate (<50%), and moderately severe (<75%) stenosis. However, mean graft flow decreased (p < 0.05) with severe stenosis (>75%).

Conclusions. Although differences in mean graft flow and graft flow morphology were detectable in anastomoses with severe stenosis (>75%), they were indistinguishable in anastomoses with mild (<25%) to moderately severe (<75%) stenosis. Flow measurement techniques are valuable tools intraoperatively, but surgeons should exercise caution in their interpretation.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
Y. Tokuda, M.-H. Song, Y. Ueda, A. Usui, and T. Akita
Predicting Early Coronary Artery Bypass Graft Failure by Intraoperative Transit Time Flow Measurement
Ann. Thorac. Surg., December 1, 2007; 84(6): 1928 - 1933.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. K. Hol, K. Andersen, H. Skulstad, P. S. Halvorsen, P. S. Lingaas, R. Andersen, J. Bergsland, and E. Fosse
Epicardial Ultrasonography: A Potential Method for Intraoperative Quality Assessment of Coronary Bypass Anastomoses?
Ann. Thorac. Surg., September 1, 2007; 84(3): 801 - 807.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
A. Jalal
An objective method for grading of distal disease in the grafted coronary arteries
Interactive CardioVascular and Thoracic Surgery, August 1, 2007; 6(4): 451 - 455.
[Abstract] [Full Text] [PDF]


Home page
Asian Cardiovasc. Thorac. Ann.Home page
K. S Ibrahim, L. Lovstakken, I. Kirkeby-Garstad, H. Torp, H. Vik-Mo, and R. Haaverstad
Effect of the Cardiac Cycle on the Coronary Anastomosis Assessed by Ultrasound
Asian Cardiovasc Thorac Ann, April 1, 2007; 15(2): 86 - 90.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
K.-B. Kim, C. H. Kang, and C. Lim
Prediction of Graft Flow Impairment by Intraoperative Transit Time Flow Measurement in Off-Pump Coronary Artery Bypass Using Arterial Grafts
Ann. Thorac. Surg., August 1, 2005; 80(2): 594 - 598.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. A.G. Louagie, J. Jamart, and A. Gruslin
Do Coronary Bypass Graft Flows Differ Between On-Pump and Off-Pump Operations?
Ann. Thorac. Surg., June 1, 2005; 79(6): 2004 - 2012.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
R. P.J. Budde, T. C. Dessing, R. Meijer, P. F.A. Bakker, C. Borst, and P. F. Grundeman
Robot-assisted 13 MHz epicardial ultrasound for endoscopic quality assessment of coronary anastomoses
Interactive CardioVascular and Thoracic Surgery, December 1, 2004; 3(4): 616 - 620.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
Y. Takami and H. Masumoto
Transit-time flow measurement cannot detect wrong anastomosis of an internal thoracic artery with the cardiac vein in coronary artery surgery
J. Thorac. Cardiovasc. Surg., October 1, 2004; 128(4): 629 - 631.
[Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
T. C. Dessing, R. P.J. Budde, R. Meijer, P. F.A. Bakker, C. Borst, and P. F. Grundeman
Geometry assessment of coronary artery anastomoses with construction errors by epicardial ultrasound
Eur. J. Cardiothorac. Surg., August 1, 2004; 26(2): 257 - 261.
[Abstract] [Full Text] [PDF]


Home page
ChestHome page
O. Reuthebuch, A. Haussler, M. Genoni, R. Tavakoli, D. Odavic, A. Kadner, and M. Turina
Novadaq SPY: Intraoperative Quality Assessment in Off-Pump Coronary Artery Bypass Grafting
Chest, February 1, 2004; 125(2): 418 - 424.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
C. Schmitz, O. Ashraf, W. Schiller, C. J. Preusse, B. Esmailzadeh, J. A. Likungu, R. Fimmers, and A. Welz
Transit time flow measurement in on-pump and off-pump coronary artery surgery
J. Thorac. Cardiovasc. Surg., September 1, 2003; 126(3): 645 - 650.
[Abstract] [Full Text] [PDF]


Home page
ICVTSHome page
Y. Suematsu, S. Takamoto, and T. Ohtsuka
Real-time three-dimensional echocardiography evaluation of graft anastomoses during coronary artery bypass grafting: preliminary experience
Interactive CardioVascular and Thoracic Surgery, September 1, 2002; 1(1): 52 - 54.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Suematsu, T. Ohtsuka, T. Miyairi, N. Motomura, and S. Takamoto
Ultrasonic evaluation of graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass
Ann. Thorac. Surg., July 1, 2002; 74(1): 273 - 275.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
P. K. Hol, E. Fosse, R. Lundblad, S. Nitter-Hauge, P. Due-Tonnessen, K. Vatne, and H.-J. Smith
The importance of intraoperative angiographic findings for predicting long-term patency in coronary artery bypass operations
Ann. Thorac. Surg., March 1, 2002; 73(3): 813 - 818.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
Y. Suematsu, S. Takamoto, and T. Ohtsuka
Intraoperative echocardiographic imaging of coronary arteries and graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass
J. Thorac. Cardiovasc. Surg., December 1, 2001; 122(6): 1147 - 1154.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. A. Wolfe
The coronary artery bypass conduit: II. Assessment of the quality of the distal anastomosis
Ann. Thorac. Surg., December 1, 2001; 72(6): S2253 - 2258.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Shin, R. Yozu, A. Mitsumaru, Y. Iino, K. Hashizume, T. Matayoshi, and S. Kawada
Intraoperative assessment of coronary artery bypass graft: transit-time flowmetry versus angiography
Ann. Thorac. Surg., November 1, 2001; 72(5): 1562 - 1565.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
P. Gersbach, C. Imsand, L. K. von Segesser, A. Delabays, P. Vogt, and F. Stumpe
Beating heart coronary artery surgery: is sternotomy a suitable alternative to minimal invasive technique?
Eur. J. Cardiothorac. Surg., October 1, 2001; 20(4): 760 - 764.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
Y. Takami and H. Ina
Relation of intraoperative flow measurement with postoperative quantitative angiographic assessment of coronary artery bypass grafting
Ann. Thorac. Surg., October 1, 2001; 72(4): 1270 - 1274.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. C. Lin, D. L. Fisher, M. F. Szwerc, and J. A. Magovern
Evaluation of graft patency during minimally invasive coronary artery bypass grafting with Doppler flow analysis
Ann. Thorac. Surg., October 1, 2000; 70(4): 1350 - 1354.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
A. Repossini, S. Moriggia, V. Cianci, O. Parodi, P. Sganzerla, G. Baldrighi, F. Bortone, and V. Arena
The LAST operation is safe and effective: MIDCABG clinical and angiographic evaluation
Ann. Thorac. Surg., July 1, 2000; 70(1): 74 - 78.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
G. Beldi, A. Bosshard, O. M. Hess, U. Althaus, and B. H. Walpoth
Transit time flow measurement: experimental validation and comparison of three different systems
Ann. Thorac. Surg., July 1, 2000; 70(1): 212 - 217.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
G. D'Ancona, H. L. Karamanoukian, M. Ricci, S. Schmid, J. Bergsland, and T. A. Salerno
Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting
Eur. J. Cardiothorac. Surg., March 1, 2000; 17(3): 287 - 293.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
S. C. Koenig, D. J. VanHimbergen, S. F. Jaber, D. L. Ewert, P. Cerrito, and P. A. Spence
Spectral analysis of graft flow for anastomotic error detection in off-pump CABG
Eur. J. Cardiothorac. Surg., September 1, 1999; 16(suppl_1): S83 - S87.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
P. B. Cerrito, S. C. Koenig, D. J. VanHimbergen, S. F. Jaber, D. L. Ewert, and P. A. Spence
Neural network pattern recognition analysis of graft flow characteristics improves intra-operative anastomotic error detection in minimally invasive CABG
Eur. J. Cardiothorac. Surg., July 1, 1999; 16(1): 88 - 93.
[Abstract] [Full Text] [PDF]


Home page
SEMIN CARDIOTHORAC VASC ANESTHHome page
T. M. McLoitghlin JR
Complications of Minimally Invasive Cardiac Surgical Procedures
Seminars in Cardiothoracic and Vascular Anesthesia, July 1, 1999; 3(2): 136 - 142.
[Abstract] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1998 by The Society of Thoracic Surgeons.