|
|
||||||||
Ann Thorac Surg 1998;66:1087-1092
© 1998 The Society of Thoracic Surgeons
a Division of Thoracic and Cardiovascular Surgery, Department of Surgery, University of Louisville, School of Medicine, Louisville, Kentucky, USA
Address reprint requests to Dr Spence, Cardiovascular Research Institute, 500 S Floyd St, Louisville, KY 40292
Presented at "Facts and Myths of Minimally Invasive Cardiac Surgery: Current Trends in Thoracic Surgery IV," New Orleans, LA, Jan 24, 1998.
Abstract
Background. Anastomotic quality is currently the critical issue in minimally invasive coronary surgery. Although little is known about its effectiveness, surgeons routinely assess grafts intraoperatively using flow probes. This study was designed to determine whether mean flow and the pattern of flow tracing in internal mammary artery grafts obtained with a transit-time flow probe are reliable indicators of anastomotic quality.
Methods. Mongrel dogs (n = 14, 30 to 35 kg) underwent off-pump left, right, or left and right internal mammary artery to left anterior descending artery anastomosis (23 grafts). Moderate to severe degrees of stenosis were created at the anastomosis by an additional suture. Internal mammary artery graft flow was measured before and after the stenosis was created with the left anterior descending artery occluded. Angiography was performed at random postoperatively to validate the degree of stenosis. Mean flow and flow tracing morphology were compared under various degrees of stenosis.
Results. There were no significant differences in mean graft flow or the morphology of the flow tracing between patent (<15%), mild (<25%), moderate (<50%), and moderately severe (<75%) stenosis. However, mean graft flow decreased (p < 0.05) with severe stenosis (>75%).
Conclusions. Although differences in mean graft flow and graft flow morphology were detectable in anastomoses with severe stenosis (>75%), they were indistinguishable in anastomoses with mild (<25%) to moderately severe (<75%) stenosis. Flow measurement techniques are valuable tools intraoperatively, but surgeons should exercise caution in their interpretation.
This article has been cited by other articles:
![]() |
Y. Tokuda, M.-H. Song, Y. Ueda, A. Usui, and T. Akita Predicting Early Coronary Artery Bypass Graft Failure by Intraoperative Transit Time Flow Measurement Ann. Thorac. Surg., December 1, 2007; 84(6): 1928 - 1933. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. K. Hol, K. Andersen, H. Skulstad, P. S. Halvorsen, P. S. Lingaas, R. Andersen, J. Bergsland, and E. Fosse Epicardial Ultrasonography: A Potential Method for Intraoperative Quality Assessment of Coronary Bypass Anastomoses? Ann. Thorac. Surg., September 1, 2007; 84(3): 801 - 807. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Jalal An objective method for grading of distal disease in the grafted coronary arteries Interactive CardioVascular and Thoracic Surgery, August 1, 2007; 6(4): 451 - 455. [Abstract] [Full Text] [PDF] |
||||
![]() |
K. S Ibrahim, L. Lovstakken, I. Kirkeby-Garstad, H. Torp, H. Vik-Mo, and R. Haaverstad Effect of the Cardiac Cycle on the Coronary Anastomosis Assessed by Ultrasound Asian Cardiovasc Thorac Ann, April 1, 2007; 15(2): 86 - 90. [Abstract] [Full Text] [PDF] |
||||
![]() |
K.-B. Kim, C. H. Kang, and C. Lim Prediction of Graft Flow Impairment by Intraoperative Transit Time Flow Measurement in Off-Pump Coronary Artery Bypass Using Arterial Grafts Ann. Thorac. Surg., August 1, 2005; 80(2): 594 - 598. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. A.G. Louagie, J. Jamart, and A. Gruslin Do Coronary Bypass Graft Flows Differ Between On-Pump and Off-Pump Operations? Ann. Thorac. Surg., June 1, 2005; 79(6): 2004 - 2012. [Abstract] [Full Text] [PDF] |
||||
![]() |
R. P.J. Budde, T. C. Dessing, R. Meijer, P. F.A. Bakker, C. Borst, and P. F. Grundeman Robot-assisted 13 MHz epicardial ultrasound for endoscopic quality assessment of coronary anastomoses Interactive CardioVascular and Thoracic Surgery, December 1, 2004; 3(4): 616 - 620. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Takami and H. Masumoto Transit-time flow measurement cannot detect wrong anastomosis of an internal thoracic artery with the cardiac vein in coronary artery surgery J. Thorac. Cardiovasc. Surg., October 1, 2004; 128(4): 629 - 631. [Full Text] [PDF] |
||||
![]() |
T. C. Dessing, R. P.J. Budde, R. Meijer, P. F.A. Bakker, C. Borst, and P. F. Grundeman Geometry assessment of coronary artery anastomoses with construction errors by epicardial ultrasound Eur. J. Cardiothorac. Surg., August 1, 2004; 26(2): 257 - 261. [Abstract] [Full Text] [PDF] |
||||
![]() |
O. Reuthebuch, A. Haussler, M. Genoni, R. Tavakoli, D. Odavic, A. Kadner, and M. Turina Novadaq SPY: Intraoperative Quality Assessment in Off-Pump Coronary Artery Bypass Grafting Chest, February 1, 2004; 125(2): 418 - 424. [Abstract] [Full Text] [PDF] |
||||
![]() |
C. Schmitz, O. Ashraf, W. Schiller, C. J. Preusse, B. Esmailzadeh, J. A. Likungu, R. Fimmers, and A. Welz Transit time flow measurement in on-pump and off-pump coronary artery surgery J. Thorac. Cardiovasc. Surg., September 1, 2003; 126(3): 645 - 650. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Suematsu, S. Takamoto, and T. Ohtsuka Real-time three-dimensional echocardiography evaluation of graft anastomoses during coronary artery bypass grafting: preliminary experience Interactive CardioVascular and Thoracic Surgery, September 1, 2002; 1(1): 52 - 54. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Suematsu, T. Ohtsuka, T. Miyairi, N. Motomura, and S. Takamoto Ultrasonic evaluation of graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass Ann. Thorac. Surg., July 1, 2002; 74(1): 273 - 275. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. K. Hol, E. Fosse, R. Lundblad, S. Nitter-Hauge, P. Due-Tonnessen, K. Vatne, and H.-J. Smith The importance of intraoperative angiographic findings for predicting long-term patency in coronary artery bypass operations Ann. Thorac. Surg., March 1, 2002; 73(3): 813 - 818. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Suematsu, S. Takamoto, and T. Ohtsuka Intraoperative echocardiographic imaging of coronary arteries and graft anastomoses during coronary artery bypass grafting without cardiopulmonary bypass J. Thorac. Cardiovasc. Surg., December 1, 2001; 122(6): 1147 - 1154. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. A. Wolfe The coronary artery bypass conduit: II. Assessment of the quality of the distal anastomosis Ann. Thorac. Surg., December 1, 2001; 72(6): S2253 - 2258. [Abstract] [Full Text] [PDF] |
||||
![]() |
H. Shin, R. Yozu, A. Mitsumaru, Y. Iino, K. Hashizume, T. Matayoshi, and S. Kawada Intraoperative assessment of coronary artery bypass graft: transit-time flowmetry versus angiography Ann. Thorac. Surg., November 1, 2001; 72(5): 1562 - 1565. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. Gersbach, C. Imsand, L. K. von Segesser, A. Delabays, P. Vogt, and F. Stumpe Beating heart coronary artery surgery: is sternotomy a suitable alternative to minimal invasive technique? Eur. J. Cardiothorac. Surg., October 1, 2001; 20(4): 760 - 764. [Abstract] [Full Text] [PDF] |
||||
![]() |
Y. Takami and H. Ina Relation of intraoperative flow measurement with postoperative quantitative angiographic assessment of coronary artery bypass grafting Ann. Thorac. Surg., October 1, 2001; 72(4): 1270 - 1274. [Abstract] [Full Text] [PDF] |
||||
![]() |
J. C. Lin, D. L. Fisher, M. F. Szwerc, and J. A. Magovern Evaluation of graft patency during minimally invasive coronary artery bypass grafting with Doppler flow analysis Ann. Thorac. Surg., October 1, 2000; 70(4): 1350 - 1354. [Abstract] [Full Text] [PDF] |
||||
![]() |
A. Repossini, S. Moriggia, V. Cianci, O. Parodi, P. Sganzerla, G. Baldrighi, F. Bortone, and V. Arena The LAST operation is safe and effective: MIDCABG clinical and angiographic evaluation Ann. Thorac. Surg., July 1, 2000; 70(1): 74 - 78. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. Beldi, A. Bosshard, O. M. Hess, U. Althaus, and B. H. Walpoth Transit time flow measurement: experimental validation and comparison of three different systems Ann. Thorac. Surg., July 1, 2000; 70(1): 212 - 217. [Abstract] [Full Text] [PDF] |
||||
![]() |
G. D'Ancona, H. L. Karamanoukian, M. Ricci, S. Schmid, J. Bergsland, and T. A. Salerno Graft revision after transit time flow measurement in off-pump coronary artery bypass grafting Eur. J. Cardiothorac. Surg., March 1, 2000; 17(3): 287 - 293. [Abstract] [Full Text] [PDF] |
||||
![]() |
S. C. Koenig, D. J. VanHimbergen, S. F. Jaber, D. L. Ewert, P. Cerrito, and P. A. Spence Spectral analysis of graft flow for anastomotic error detection in off-pump CABG Eur. J. Cardiothorac. Surg., September 1, 1999; 16(suppl_1): S83 - S87. [Abstract] [Full Text] [PDF] |
||||
![]() |
P. B. Cerrito, S. C. Koenig, D. J. VanHimbergen, S. F. Jaber, D. L. Ewert, and P. A. Spence Neural network pattern recognition analysis of graft flow characteristics improves intra-operative anastomotic error detection in minimally invasive CABG Eur. J. Cardiothorac. Surg., July 1, 1999; 16(1): 88 - 93. [Abstract] [Full Text] [PDF] |
||||
![]() |
T. M. McLoitghlin JR Complications of Minimally Invasive Cardiac Surgical Procedures Seminars in Cardiothoracic and Vascular Anesthesia, July 1, 1999; 3(2): 136 - 142. [Abstract] [PDF] |
||||
| HOME | HELP | FEEDBACK | SUBSCRIPTIONS | ARCHIVE | SEARCH | TABLE OF CONTENTS |
| ANN THORAC SURG | ASIAN CARDIOVASC THORAC ANN | EUR J CARDIOTHORAC SURG |
| J THORAC CARDIOVASC SURG | ICVTS | ALL CTSNet JOURNALS |