ATS
HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
 QUICK SEARCH:   [advanced]


     


This Article
Right arrow Full Text
Right arrow Full Text (PDF)
Right arrow Alert me when this article is cited
Right arrow Alert me if a correction is posted
Right arrow Citation Map
Services
Right arrow Email this article to a friend
Right arrow Similar articles in this journal
Right arrow Similar articles in PubMed
Right arrow Alert me to new issues of the journal
Right arrow Add to Personal Folders
Right arrow Download to citation manager
Right arrow Author home page(s):
Joseph R. Elbeery
Right arrow Permission Requests
Citing Articles
Right arrow Citing Articles via HighWire
Right arrow Citing Articles via Google Scholar
Google Scholar
Right arrow Articles by Elbeery, J. R.
Right arrow Articles by Chitwood, W. R.
Right arrow Search for Related Content
PubMed
Right arrow PubMed Citation
Right arrow Articles by Elbeery, J. R.
Right arrow Articles by Chitwood, W. R., Jr

Ann Thorac Surg 1998;66:51-55
© 1998 The Society of Thoracic Surgeons


Original articles: cardiovascular

Intraoperative MIDCABG arteriography via the left radial artery: a comparison with doppler ultrasound for assessment of graft patency

Joseph R. Elbeery, MDa, Philip M. Brown, MDa, W. Randolph Chitwood, Jr, MDa

a Division of Cardiothoracic Surgery, East Carolina University School of Medicine, Greenville, North Carolina, USA

Address reprint requests to Dr Elbeery, Division of Cardiothoracic Surgery, East Carolina University School of Medicine, 600 Moye Blvd, Greenville, NC 27858-4354
e-mail: (elbeery{at}brody.med.ecu.edu)

Presented at the Forty-fourth Annual Meeting of the Southern Thoracic Surgical Association, Naples, FL, Nov 6–8, 1997.

Background. Minimally invasive direct coronary artery bypass grafting involving beating heart left internal mammary artery to left anterior descending coronary artery anastomoses are performed with increasing frequency. Controversy exists regarding the need for intraoperative assessment of graft patency.

Methods. We designed a technique to perform arteriography of the left internal mammary artery by using left radial artery access and standard fluoroscopy to evaluate patency in the operating room. The last 50 of 87 minimally invasive direct coronary artery bypass grafting operations were evaluated by intraoperative arteriography and Doppler ultrasound. Angiograms were performed by the surgeon and involved cannulation and direct injection of contrast medium into the origin of the left internal mammary artery via the left radial artery.

Results. Total procedure time was less than 15 minutes. No injuries to the left internal mammary artery were identified. Anastomotic occlusions were identified in 4 cases (8%), 2 of which involved sequential diagonal and left anterior descending anastomoses. These were corrected at the time of surgery with 2 cases requiring conversion to standard coronary artery bypass grafting. Qualitative assessment of grafts with Doppler ultrasound failed to definitively identify these occlusions. There were no deaths and no perioperative infarctions.

Conclusion. Intraoperative arteriography of the left internal mammary artery can be performed by the surgeon, and a significant number of anastomotic problems may be identified and corrected by using this technique. Therefore, a 100% early graft patency rate may be attainable.




This article has been cited by other articles:


Home page
Ann. Thorac. Surg.Home page
B. Kogon, J. Fernandez, K. Kanter, P. Kirshbom, B. Vincent, K. Maher, and N. Guzetta
The role of intraoperative indocyanine green fluorescence angiography in pediatric cardiac surgery.
Ann. Thorac. Surg., August 1, 2009; 88(2): 632 - 636.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
L. Balacumaraswami and D. P. Taggart
Intraoperative Imaging Techniques to Assess Coronary Artery Bypass Graft Patency
Ann. Thorac. Surg., June 1, 2007; 83(6): 2251 - 2257.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
N. D. Desai, S. Miwa, D. Kodama, T. Koyama, G. Cohen, M. P. Pelletier, E. A. Cohen, G. T. Christakis, B. S. Goldman, and S. E. Fremes
A randomized comparison of intraoperative indocyanine green angiography and transit-time flow measurement to detect technical errors in coronary bypass grafts
J. Thorac. Cardiovasc. Surg., September 1, 2006; 132(3): 585 - 594.
[Abstract] [Full Text] [PDF]


Home page
J Am Coll CardiolHome page
N. D. Desai, S. Miwa, D. Kodama, G. Cohen, G. T. Christakis, B. S. Goldman, M. O. Baerlocher, M. P. Pelletier, and S. E. Fremes
Improving the Quality of Coronary Bypass Surgery With Intraoperative Angiography: Validation of a New Technique
J. Am. Coll. Cardiol., October 18, 2005; 46(8): 1521 - 1525.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
L. Balacumaraswami, Y. Abu-Omar, B. Choudhary, D. Pigott, and D. P. Taggart
A comparison of transit-time flowmetry and intraoperative fluorescence imaging for assessing coronary artery bypass graft patency
J. Thorac. Cardiovasc. Surg., August 1, 2005; 130(2): 315 - 320.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
T. Yasuda, G. Watanabe, and S. Tomita
Transaortic injection technique in fluorescence imaging: Novel intraoperative assessment of anastomosis in off-pump coronary artery bypass grafting
J. Thorac. Cardiovasc. Surg., August 1, 2005; 130(2): 560 - 561.
[Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
B. Sonmez, H. Arbatli, S. Tansal, N. Yagan, M. Unal, E. Demirsoy, F. Tukenmez, and O. Yilmaz
Real-time patency control with thermal coronary angiography in 1401 coronary artery bypass grafting patients
Eur. J. Cardiothorac. Surg., December 1, 2003; 24(6): 961 - 966.
[Abstract] [Full Text] [PDF]


Home page
J. Thorac. Cardiovasc. Surg.Home page
R. K. Wolf, E. L. Alderman, M. P. Caskey, A. R. Raczkowski, M. K. Dullum, D. C. Lundell, A. C. Hill, N. Wang, and M. A. Daniel
Clinical and six-month angiographic evaluation of coronary arterial graft interrupted anastomoses by use of a self-closing clip device: a multicenter prospective clinical trial
J. Thorac. Cardiovasc. Surg., July 1, 2003; 126(1): 168 - 177.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
D. P. Taggart, B. Choudhary, K. Anastasiadis, Y. Abu-Omar, L. Balacumaraswami, and D. W. Pigott
Preliminary experience with a novel intraoperative fluorescence imaging technique to evaluate the patency of bypass grafts in total arterial revascularization
Ann. Thorac. Surg., March 1, 2003; 75(3): 870 - 873.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. A. Wolfe
The coronary artery bypass conduit: II. Assessment of the quality of the distal anastomosis
Ann. Thorac. Surg., December 1, 2001; 72(6): S2253 - 2258.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
H. Shin, R. Yozu, A. Mitsumaru, Y. Iino, K. Hashizume, T. Matayoshi, and S. Kawada
Intraoperative assessment of coronary artery bypass graft: transit-time flowmetry versus angiography
Ann. Thorac. Surg., November 1, 2001; 72(5): 1562 - 1565.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
J. C. Lin, D. L. Fisher, M. F. Szwerc, and J. A. Magovern
Evaluation of graft patency during minimally invasive coronary artery bypass grafting with Doppler flow analysis
Ann. Thorac. Surg., October 1, 2000; 70(4): 1350 - 1354.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
T. A. Vassiliades Jr, E. W. Rogers, J. L. Nielsen, and J. L. Lonquist
Minimally invasive direct coronary artery bypass grafting: intermediate-term results
Ann. Thorac. Surg., September 1, 2000; 70(3): 1063 - 1065.
[Abstract] [Full Text] [PDF]


Home page
Ann. Thorac. Surg.Home page
W. R. Chitwood Jr, C. L. Wixon, J. R. Elbeery, N. A. Francalancia, and R. M. Lust
Minimally invasive cardiac operation: adapting cardioprotective strategies
Ann. Thorac. Surg., November 1, 1999; 68(5): 1974 - 1977.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
R. W. Emery, K. V. Arom, T. F. Flavin, and A. M. Emery
A case for minimally invasive coronary surgery as primary treatment for left anterior descending coronary artery disease
Eur. J. Cardiothorac. Surg., November 1, 1999; 16(suppl_2): S112 - S116.
[Abstract] [Full Text] [PDF]


Home page
Eur. J. Cardiothorac. Surg.Home page
J. Cremer, A. Mugge, T. Wittwer, A. Boening, P. Kim, T. Kofidis, H. Drexler, and A. Haverich
Early angiographic results after revascularization by minimally invasive direct coronary artery bypass (MIDCAB)
Eur. J. Cardiothorac. Surg., April 1, 1999; 15(4): 383 - 388.
[Abstract] [Full Text] [PDF]




HOME HELP FEEDBACK SUBSCRIPTIONS ARCHIVE SEARCH TABLE OF CONTENTS
ANN THORAC SURG ASIAN CARDIOVASC THORAC ANN EUR J CARDIOTHORAC SURG
J THORAC CARDIOVASC SURG ICVTS ALL CTSNet JOURNALS
Copyright © 1998 by The Society of Thoracic Surgeons.